Installation Guide
Page 1
Installation Guide 3ware® SATA RAID Controller Supports the 9000 Series PN 720-0117-01 March 2005
Installation Guide 3ware® SATA RAID Controller Supports the 9000 Series PN 720-0117-01 March 2005
Installation Guide
Page 11
... of features and system requirements, refer to , four, eight, or twelve SATA drives using the open source Linux driver FreeBSD Other Requirements Adequate air flow and cooling Adequate power supply for serial ATA controllers. Operating System 3ware RAID controllers may be used with: Windows 2000 (Professional, Server, Advanced Server...
... of features and system requirements, refer to , four, eight, or twelve SATA drives using the open source Linux driver FreeBSD Other Requirements Adequate air flow and cooling Adequate power supply for serial ATA controllers. Operating System 3ware RAID controllers may be used with: Windows 2000 (Professional, Server, Advanced Server...
Installation Guide
Page 24
... (Battery Backup Unit) connector Figure 4. 4-Port 3ware 9500S-4 Serial ATA RAID Controller To connect serial cables to the controller 1 Take out the serial cables provided with the 3ware SATA RAID controller. 3ware serial controllers are supplied with the connector on the controller, matching the slotted key and carefully mate the connectors. 16 3ware 9000 Series Serial ATA RAID Controller Installation Guide One edge of each...
... (Battery Backup Unit) connector Figure 4. 4-Port 3ware 9500S-4 Serial ATA RAID Controller To connect serial cables to the controller 1 Take out the serial cables provided with the 3ware SATA RAID controller. 3ware serial controllers are supplied with the connector on the controller, matching the slotted key and carefully mate the connectors. 16 3ware 9000 Series Serial ATA RAID Controller Installation Guide One edge of each...
Installation Guide
Page 26
...22. 18 3ware 9000 Series Serial ATA RAID Controller Installation Guide Be... sure that was used to enable staggered spinup. For more information, see "Whether to Use the LED Status Connector" on page 9 and "To connect serial cables to the controller... fully seated. 8 Check that the 3ware RAID controller's metal bracket covers the hole in ... to make these connections, see the 3ware 9000 Series Serial ATA RAID Controller User Guide. 5 Turn to ensure ...Press down gently on the edge of the 3ware RAID controller directly above the slot until it into the...
...22. 18 3ware 9000 Series Serial ATA RAID Controller Installation Guide Be... sure that was used to enable staggered spinup. For more information, see "Whether to Use the LED Status Connector" on page 9 and "To connect serial cables to the controller... fully seated. 8 Check that the 3ware RAID controller's metal bracket covers the hole in ... to make these connections, see the 3ware 9000 Series Serial ATA RAID Controller User Guide. 5 Turn to ensure ...Press down gently on the edge of the 3ware RAID controller directly above the slot until it into the...
Installation Guide
Page 28
... on the other end of the individual SATA connectors to a multi-lane connector on the model of the controller and the number of drives you will be connecting, you are using a standard enclosure, connect each of each interface cable to a drive. 20 3ware 9000 Series Serial ATA RAID Controller Installation Guide See Figure 5. If you...
... on the other end of the individual SATA connectors to a multi-lane connector on the model of the controller and the number of drives you will be connecting, you are using a standard enclosure, connect each of each interface cable to a drive. 20 3ware 9000 Series Serial ATA RAID Controller Installation Guide See Figure 5. If you...
Installation Guide
Page 126
... array 28 module names for RedHat Linux 71 motherboard boot sequence 51 multilane cable, with individual SATA connectors 20 multilane cable, with multilane connectors on each end (847) 20 P PCI slots 8 R RAID concepts and levels 28 RAID level to use, determining 31 Red Hat Linux, installing driver under 68 RedHat kernel strings 71... 10 Troubleshooting 97 troubleshooting 97 U units configuring 27, 40 initializing 49 W Warranty 112 Windows, installing driver under 53 write cache, enabling or disabling 43 118 3ware 9000 Series Serial ATA RAID Controller Installation Guide
... array 28 module names for RedHat Linux 71 motherboard boot sequence 51 multilane cable, with individual SATA connectors 20 multilane cable, with multilane connectors on each end (847) 20 P PCI slots 8 R RAID concepts and levels 28 RAID level to use, determining 31 Red Hat Linux, installing driver under 68 RedHat kernel strings 71... 10 Troubleshooting 97 troubleshooting 97 U units configuring 27, 40 initializing 49 W Warranty 112 Windows, installing driver under 53 write cache, enabling or disabling 43 118 3ware 9000 Series Serial ATA RAID Controller Installation Guide
User Guide
Page 12
...64-bit x86 SuSE Linux, 32-bit and 64-bit x64 6 3ware 9000 Series Serial ATA RAID Controller User Guide Drives must meet serial ATA 150 (SATA-1)or serial ATA 300 (SATA 2) Gb/s standards. The length of shielded and unshielded interface cables may not ...PCI or PCI-X slot for serial ATA controllers. Operating System 3ware RAID controllers may be connected to up to two, four, eight, or twelve SATA drives using Stream Fusion technology. Extended drive and unit status information. System Requirements 3ware RAID controllers require the following A workstation-class...
...64-bit x86 SuSE Linux, 32-bit and 64-bit x64 6 3ware 9000 Series Serial ATA RAID Controller User Guide Drives must meet serial ATA 150 (SATA-1)or serial ATA 300 (SATA 2) Gb/s standards. The length of shielded and unshielded interface cables may not ...PCI or PCI-X slot for serial ATA controllers. Operating System 3ware RAID controllers may be connected to up to two, four, eight, or twelve SATA drives using Stream Fusion technology. Extended drive and unit status information. System Requirements 3ware RAID controllers require the following A workstation-class...
User Guide
Page 82
... spinup. Indicates whether write cache will be exported to the operating system. If your drives support the SATA OOB method, select that you want to use on the controller. JBOD configuration is ATA-6 or SATA OOB (Out Of Band). The delay time (in seconds) between drive groups that spin up , ... method, so it must be set or changed in 3BM, however you can only be set 76 3ware 9000 Series Serial ATA RAID Controller User Guide If you have a JBOD configuration from a 7000/8000 controller that method here. By default, when Staggered Spinup is enabled, the ATA-6 scheme is enabled), in...
... spinup. Indicates whether write cache will be exported to the operating system. If your drives support the SATA OOB method, select that you want to use on the controller. JBOD configuration is ATA-6 or SATA OOB (Out Of Band). The delay time (in seconds) between drive groups that spin up , ... method, so it must be set or changed in 3BM, however you can only be set 76 3ware 9000 Series Serial ATA RAID Controller User Guide If you have a JBOD configuration from a 7000/8000 controller that method here. By default, when Staggered Spinup is enabled, the ATA-6 scheme is enabled), in...
User Guide
Page 85
...Staggered Method: Select either ATA-6 or SATA OOB as the type of staggered spinup you want to use of a second drive failure, the software RAID layer can enable auto-carving. disabled to disable it overrides the write cache setting specified for a Controller through 3BM 2 On the Policy Control screen, Tab through these fields, making...enable staggered spinup; You will notice a short delay as 3BM makes the policy changes. If case of the full capacity in excess of the 3ware RAID configuration. To gain use : Staggered Spinup: Select enabled to the OK button and press Enter.
...Staggered Method: Select either ATA-6 or SATA OOB as the type of staggered spinup you want to use of a second drive failure, the software RAID layer can enable auto-carving. disabled to disable it overrides the write cache setting specified for a Controller through 3BM 2 On the Policy Control screen, Tab through these fields, making...enable staggered spinup; You will notice a short delay as 3BM makes the policy changes. If case of the full capacity in excess of the 3ware RAID configuration. To gain use : Staggered Spinup: Select enabled to the OK button and press Enter.
User Guide
Page 189
...are subunits of one mirror with SATA disk drives. Unit ID. A logical unit of storage that confirms the validity of a particular unit. Unit. For RAID 5 and RAID 50, a verify will compare the data of the RAID 10 unit. UDMA mode. www.3ware.com 183 A major stripe size... is part of disks in a system. Unit Number. For example, the mirrored pairs (RAID 1) in RAID 0, 5, 10 and 50. Subunit...
...are subunits of one mirror with SATA disk drives. Unit ID. A logical unit of storage that confirms the validity of a particular unit. Unit. For RAID 5 and RAID 50, a verify will compare the data of the RAID 10 unit. UDMA mode. www.3ware.com 183 A major stripe size... is part of disks in a system. Unit Number. For example, the mirrored pairs (RAID 1) in RAID 0, 5, 10 and 50. Subunit...