User Guide
Page 21
... your IP SAN from a centralized location Provision storage to the system manually Adaptec Multipath Input Output (MPIO) Device Specific Module (DSM) Driver VMware® ESX Server 3.x.x Provision storage to -date list of supported OSs. Refer to the Adaptec Web site at www.adaptec.com for the most up-to the system manually Note: No other...
... your IP SAN from a centralized location Provision storage to the system manually Adaptec Multipath Input Output (MPIO) Device Specific Module (DSM) Driver VMware® ESX Server 3.x.x Provision storage to -date list of supported OSs. Refer to the Adaptec Web site at www.adaptec.com for the most up-to the system manually Note: No other...
User Guide
Page 23
...support includes: • Multipath Input Output (MPIO) Device Specific Module (DSM) Driver-Supports multiple redundant physical paths between your iSCSI Storage Appliance and your iSCSI Storage Appliances to be added to Adaptec Storage Manager, if you install the Management Service on any system that will be... an iSCSI Storage Host. Note You can be configured and managed separately from others. See "Installing Adaptec Storage Manager" on systems running Windows 2003 R2 only. • Provisioning Agent-Automates functions such as volume and snapshot creation. See ...
...support includes: • Multipath Input Output (MPIO) Device Specific Module (DSM) Driver-Supports multiple redundant physical paths between your iSCSI Storage Appliance and your iSCSI Storage Appliances to be added to Adaptec Storage Manager, if you install the Management Service on any system that will be... an iSCSI Storage Host. Note You can be configured and managed separately from others. See "Installing Adaptec Storage Manager" on systems running Windows 2003 R2 only. • Provisioning Agent-Automates functions such as volume and snapshot creation. See ...
User Guide
Page 80
...press F5 then try creating the mirror plex again. Creating a Mirrored Volume You can 't occur. Note The MPIO DSM driver (see page 115) and the job begins. Note If Adaptec Storage Manager displays a message that 's accessing the volume. The Job Manager opens (see page 17) must be installed ...-click the volume you want to adjust the capacity display units. 4 Click Next, review the mirror settings, then click Apply. Without the MPIO driver, automatic failover can mirror a new volume or an existing volume. The Define Remote Mirror Plex window opens. 2 In the Pools list, select the...
...press F5 then try creating the mirror plex again. Creating a Mirrored Volume You can 't occur. Note The MPIO DSM driver (see page 115) and the job begins. Note If Adaptec Storage Manager displays a message that 's accessing the volume. The Job Manager opens (see page 17) must be installed ...-click the volume you want to adjust the capacity display units. 4 Click Next, review the mirror settings, then click Apply. Without the MPIO driver, automatic failover can mirror a new volume or an existing volume. The Define Remote Mirror Plex window opens. 2 In the Pools list, select the...
User Guide
Page 93
...driver or iSCSI Storage Appliance View Properties window of all storage Create, modify, or delete a pool, volume, or logical components of your iSCSI storage as described in this table. Operators can ... Understanding Access Privilege Levels This section describes the two access privilege levels supported by Adaptec... Storage Manager. Blink a hardware component, such as a Provision storage to your IP SAN, as required. Adaptec Storage Manager requires at least one Administrator-level user. Operators...
...driver or iSCSI Storage Appliance View Properties window of all storage Create, modify, or delete a pool, volume, or logical components of your iSCSI storage as described in this table. Operators can ... Understanding Access Privilege Levels This section describes the two access privilege levels supported by Adaptec... Storage Manager. Blink a hardware component, such as a Provision storage to your IP SAN, as required. Adaptec Storage Manager requires at least one Administrator-level user. Operators...
User Guide
Page 171
... XP and Windows 2003 operating systems, Microsoft does not support "dynamic" disks for use with the Microsoft initiator to install the Microsoft MPIO driver during iSCSI initiator installation. Adaptec recommends using the QLogic QLA4050/4052, which supports "dynamic disks", or using the MS initiator to connect to iSCSI targets in your iSCSI...
... XP and Windows 2003 operating systems, Microsoft does not support "dynamic" disks for use with the Microsoft initiator to install the Microsoft MPIO driver during iSCSI initiator installation. Adaptec recommends using the QLogic QLA4050/4052, which supports "dynamic disks", or using the MS initiator to connect to iSCSI targets in your iSCSI...
User Guide
Page 178
...HBA Note Before installing qlogic iscsi HBA in the initiator system identified, uninstall the MSFT iscsi software initiator to see 2 separate driver install for Network adapter and iscsi adapter. 4 Install the SAN surfer management software (version: 5.0.0.32). The default password is... and assign a static/dhcp. 6 Launch the SAN surfer and connect to install Ethernet driver and iscsi driver for Microsoft Windows Requirements • Windows 2003, Windows 2000, Windows XP installed server. • Microsoft iSCSI Software Initiator. Setting Up SAN Boot from q-logic support site ...
...HBA Note Before installing qlogic iscsi HBA in the initiator system identified, uninstall the MSFT iscsi software initiator to see 2 separate driver install for Network adapter and iscsi adapter. 4 Install the SAN surfer management software (version: 5.0.0.32). The default password is... and assign a static/dhcp. 6 Launch the SAN surfer and connect to install Ethernet driver and iscsi driver for Microsoft Windows Requirements • Windows 2003, Windows 2000, Windows XP installed server. • Microsoft iSCSI Software Initiator. Setting Up SAN Boot from q-logic support site ...
User Guide
Page 211
... the REBOOT property to reboot following features. l VDSProvider (Windows Server 2003 x86 only)-Installs support for VDS for Adaptec Storage Manager. Also requires that you don't specify it. l Agent-Installs the Adaptec Storage Manager Direct Attached Storage Agent. If necessary, use the filter driver are installed. user intervention is installed, the machine will reboot...
... the REBOOT property to reboot following features. l VDSProvider (Windows Server 2003 x86 only)-Installs support for VDS for Adaptec Storage Manager. Also requires that you don't specify it. l Agent-Installs the Adaptec Storage Manager Direct Attached Storage Agent. If necessary, use the filter driver are installed. user intervention is installed, the machine will reboot...
User Guide
Page 212
... l Suppress-Suppresses a reboot unless files were in password to a different installation path: setup.exe /s /v"/qn ADDLOCAL=Console INSTALLDIR=\"C:\Adaptec Storage Manager\"" • To install and have installed the DSM feature, or if any files can't be overwritten. l ReallySuppress-Suppresses...COMP1234): setup.exe /s /v"/qn ADDLOCAL=VDSExternal,VSSExternal MGMTLOC=COMP1234 MGMTUSER=admin MGMTPASS=pass" You must click the Windows driver installation dialog box to successfully complete the DSM installation. (This is required only if VDSExternal or VSSExternal features are ...
... l Suppress-Suppresses a reboot unless files were in password to a different installation path: setup.exe /s /v"/qn ADDLOCAL=Console INSTALLDIR=\"C:\Adaptec Storage Manager\"" • To install and have installed the DSM feature, or if any files can't be overwritten. l ReallySuppress-Suppresses...COMP1234): setup.exe /s /v"/qn ADDLOCAL=VDSExternal,VSSExternal MGMTLOC=COMP1234 MGMTUSER=admin MGMTPASS=pass" You must click the Windows driver installation dialog box to successfully complete the DSM installation. (This is required only if VDSExternal or VSSExternal features are ...
User Guide
Page 217
... Feature Support by OS Supported Adaptec Storage Manager Features Windows Support Components OS with Latest Service Pack GUI and Management Multipath Provisioning VDS VSS Agent Service Driver Agent Provider Provider Windows OSs Windows Server 2003: Enterprise Edition Enterprise Edition R2 Standard Edition Standard Edition R2 Web Edition ✔ ✔ ✔ ✔ ✔ ✔...
... Feature Support by OS Supported Adaptec Storage Manager Features Windows Support Components OS with Latest Service Pack GUI and Management Multipath Provisioning VDS VSS Agent Service Driver Agent Provider Provider Windows OSs Windows Server 2003: Enterprise Edition Enterprise Edition R2 Standard Edition Standard Edition R2 Web Edition ✔ ✔ ✔ ✔ ✔ ✔...
User Guide
Page 226
Windows Support comprises these components: MPIO DSM (Multipath Driver), Two disk drives, where one disk drive is a mirror of the other (the same data is a collection of enhanced Adaptec Storage Manager components that lets you want to back up your data with snapshots. A component of the Windows ... systems. Windows Support is stored on your IP SAN if you create application- See also snapshot, Windows Support. Collective term for Windows Server 2003 (all iSCSI Storage Hosts on iSCSI Storage Hosts only. A component of the volumes on each disk drive)., VDS Provider, and VSS...
Windows Support comprises these components: MPIO DSM (Multipath Driver), Two disk drives, where one disk drive is a mirror of the other (the same data is a collection of enhanced Adaptec Storage Manager components that lets you want to back up your data with snapshots. A component of the Windows ... systems. Windows Support is stored on your IP SAN if you create application- See also snapshot, Windows Support. Collective term for Windows Server 2003 (all iSCSI Storage Hosts on iSCSI Storage Hosts only. A component of the volumes on each disk drive)., VDS Provider, and VSS...
User Guide
Page 228
Windows Support 18 introduction 13 iSCSI Storage Appliance 92 logging in 47 main window 52 Management Service 91 MPIO DSM Driver 17 navigating 51 Operators 87 permission levels 87 Provisioning Agent 17 reconnecting to iSCSI Storage Appliance 155 registering an iSCSI Storage...troubleshooting 143-160 unblocking ports 32 uninstalling 60 Linux 60 Windows 60 updating 139 VDS Provider 17 VSS Provider 17 Windows Support components 17 Adaptec Storage Manager Agent 16 adding iSCSI Storage Appliance 92 adding iSCSI Storage Hosts 92 adding Management Services 91 ADDLOCAL 205 administrator password (default...
Windows Support 18 introduction 13 iSCSI Storage Appliance 92 logging in 47 main window 52 Management Service 91 MPIO DSM Driver 17 navigating 51 Operators 87 permission levels 87 Provisioning Agent 17 reconnecting to iSCSI Storage Appliance 155 registering an iSCSI Storage...troubleshooting 143-160 unblocking ports 32 uninstalling 60 Linux 60 Windows 60 updating 139 VDS Provider 17 VSS Provider 17 Windows Support components 17 Adaptec Storage Manager Agent 16 adding iSCSI Storage Appliance 92 adding iSCSI Storage Hosts 92 adding Management Services 91 ADDLOCAL 205 administrator password (default...
User Guide
Page 233
...selecting disk drives 39 size 39 SRP authentication settings 44 viewing disk drives 56 Logical Devices View 52, 56 logical drives. See MPIO DSM Driver N Network Attached Storage disabling remote discovery 135 display options 140 See logical devices M main window 52 display groups 141 display options 141 ... Event Viewer 118 jobs 115-117 jobs in progress 115 Network Attached Storage 132-138 Snap Servers (GuardianOS-powered) 132-138 SNMP trap notifications 130-131 status icons 119, 133 status of IP SAN 118 MPIO DSM Driver 17 operating system support 211 Multipath Input Output Device Specific Module...
...selecting disk drives 39 size 39 SRP authentication settings 44 viewing disk drives 56 Logical Devices View 52, 56 logical drives. See MPIO DSM Driver N Network Attached Storage disabling remote discovery 135 display options 140 See logical devices M main window 52 display groups 141 display options 141 ... Event Viewer 118 jobs 115-117 jobs in progress 115 Network Attached Storage 132-138 Snap Servers (GuardianOS-powered) 132-138 SNMP trap notifications 130-131 status icons 119, 133 status of IP SAN 118 MPIO DSM Driver 17 operating system support 211 Multipath Input Output Device Specific Module...