User Guide
Page 11
... Loop Identifier Map 6-5 LIO JBOD Module Configurations 6-6 Single Loop (Nonredundant) Operation 6-6 Dual Loop Operation 6-6 Quad Loop Operation 6-6 2 Gb/sec Operation 6-7 Daisy-chaining FC Storage Enclosures 6-7 Speed Mismatches between Enclosures 6-7 Option Slot Loop AL_PA Assignments 6-7 LIO Module LEDs 6-7 Storage Enclosure LEDs 6-8 Drive Carrier LEDs 6-8 7 Ultra320 SCSI Storage Enclosures About the Adaptec SC4100 Storage Enclosure 7-2 Disk...
... Loop Identifier Map 6-5 LIO JBOD Module Configurations 6-6 Single Loop (Nonredundant) Operation 6-6 Dual Loop Operation 6-6 Quad Loop Operation 6-6 2 Gb/sec Operation 6-7 Daisy-chaining FC Storage Enclosures 6-7 Speed Mismatches between Enclosures 6-7 Option Slot Loop AL_PA Assignments 6-7 LIO Module LEDs 6-7 Storage Enclosure LEDs 6-8 Drive Carrier LEDs 6-8 7 Ultra320 SCSI Storage Enclosures About the Adaptec SC4100 Storage Enclosure 7-2 Disk...
User Guide
Page 15
... by Spheras RAIDWatch. Note: The FS4100, SC4100, and FC4100 enclosures are : ■ Adaptec FS4100 Fibre Channel-to-Serial ATA JBOD enclosure ■ Adaptec FS4500 Fibre Channel-to basic installation and maintenance information, this Guide In addition to -Serial ATA RAID enclosure ■ Adaptec SC4100 Ultra320 SCSI JBOD enclosure ■ Adaptec FC4100 Fibre Channel JBOD enclosure The Guide assumes that present...
... by Spheras RAIDWatch. Note: The FS4100, SC4100, and FC4100 enclosures are : ■ Adaptec FS4100 Fibre Channel-to-Serial ATA JBOD enclosure ■ Adaptec FS4500 Fibre Channel-to basic installation and maintenance information, this Guide In addition to -Serial ATA RAID enclosure ■ Adaptec SC4100 Ultra320 SCSI JBOD enclosure ■ Adaptec FC4100 Fibre Channel JBOD enclosure The Guide assumes that present...
User Guide
Page 28
JBOD Configuration (FS4100) FS4100 SATA I/O Module HOST 1 EXP 1 HOST 2 EXP 2 HOST BUS ADAPTER HOST BUS ADAPTER Daisy-chain to next FS4100 Daisy-chain to next FS4100 ... ADAPTER Daisy-chain to FS4100 2-10 Ensure that you have removable Small Form-factor Pluggable (SFP) connectors that support copper or optical cables. See the Adaptec 2U Storage Enclosure Installation and User's Guide on the CD for more cabling information and for your cables. Installing the Storage Enclosure Connecting SATA Cables...
JBOD Configuration (FS4100) FS4100 SATA I/O Module HOST 1 EXP 1 HOST 2 EXP 2 HOST BUS ADAPTER HOST BUS ADAPTER Daisy-chain to next FS4100 Daisy-chain to next FS4100 ... ADAPTER Daisy-chain to FS4100 2-10 Ensure that you have removable Small Form-factor Pluggable (SFP) connectors that support copper or optical cables. See the Adaptec 2U Storage Enclosure Installation and User's Guide on the CD for more cabling information and for your cables. Installing the Storage Enclosure Connecting SATA Cables...
User Guide
Page 46
...Enclosure models. 5-1 5 SATA Storage Enclosures (FS4100 and FS4500) In this Chapter.... The Adaptec SATA Storage Enclosure can be configured as either a JBOD or as a RAID enclosure: ■ The FS4100 has one or two JBOD I/O modules. ■ The FS4500 has one or two RAID I /O Module Configuration ...5-7 This chapter introduces the Adaptec SATA Storage Enclosure and describes how to cable and configure it as part of a complete storage subsystem. ...
...Enclosure models. 5-1 5 SATA Storage Enclosures (FS4100 and FS4500) In this Chapter.... The Adaptec SATA Storage Enclosure can be configured as either a JBOD or as a RAID enclosure: ■ The FS4100 has one or two JBOD I/O modules. ■ The FS4500 has one or two RAID I /O Module Configuration ...5-7 This chapter introduces the Adaptec SATA Storage Enclosure and describes how to cable and configure it as part of a complete storage subsystem. ...
User Guide
Page 47
...the location of each drive slot. The FS4100 (JBOD) has two Host ports and two Expansion ports. The FS4500 (RAID) module has two Host ports and one APC. I/O Modules The SATA I /O Modules Model Number Adaptec FS4100 Adaptec FS4500 Host Connection Fibre Channel Fibre Channel Disk ...Connection SATA SATA Disk Organization JBOD RAID 5-2 Spin-up is shown in the Storage Enclosure provide enough power for 12 disk drives...
...the location of each drive slot. The FS4100 (JBOD) has two Host ports and two Expansion ports. The FS4500 (RAID) module has two Host ports and one APC. I/O Modules The SATA I /O Modules Model Number Adaptec FS4100 Adaptec FS4500 Host Connection Fibre Channel Fibre Channel Disk ...Connection SATA SATA Disk Organization JBOD RAID 5-2 Spin-up is shown in the Storage Enclosure provide enough power for 12 disk drives...
User Guide
Page 48
... for all data rates. ■ Maximum lengths at 2 Gb/sec are 300 m of 62.5 µm cable and 500 meters of 1.5 Gb/sec. The Adaptec FS4500 Storage Enclosure supports RAID levels 0, 1, 0+1, 3, 5, 10, 30, and 50. SATA Cables Hosts communicate with an active SFP connector. Single SATA Configurations A... to form both single and dual SATA configurations. SATA Storage Enclosures (FS4100 and FS4500) Both I/O modules use SFP connectors, and accept either FS4100 (JBOD) or FS4500 (RAID) and can be connected to one I/O module, either a copper SFP connected to a copper cable, or an optical SFP ...
... for all data rates. ■ Maximum lengths at 2 Gb/sec are 300 m of 62.5 µm cable and 500 meters of 1.5 Gb/sec. The Adaptec FS4500 Storage Enclosure supports RAID levels 0, 1, 0+1, 3, 5, 10, 30, and 50. SATA Cables Hosts communicate with an active SFP connector. Single SATA Configurations A... to form both single and dual SATA configurations. SATA Storage Enclosures (FS4100 and FS4500) Both I/O modules use SFP connectors, and accept either FS4100 (JBOD) or FS4500 (RAID) and can be connected to one I/O module, either a copper SFP connected to a copper cable, or an optical SFP ...
User Guide
Page 49
... can be connected to one FS4500.) Table 5-2 SATA Configurations Single SATA Configuration Dual SATA Configuration Adaptec FS4100 1 2 Adaptec FS4500 1 2 Flexibility and Limitations ■ The FS4500 RAID single controller configuration can be upgraded to dual controllers. ■ The FS4100 JBOD single I /O modules together in the same Storage Enclosure. The redundant controller provides data access...
... can be connected to one FS4500.) Table 5-2 SATA Configurations Single SATA Configuration Dual SATA Configuration Adaptec FS4100 1 2 Adaptec FS4500 1 2 Flexibility and Limitations ■ The FS4500 RAID single controller configuration can be upgraded to dual controllers. ■ The FS4100 JBOD single I /O modules together in the same Storage Enclosure. The redundant controller provides data access...
User Guide
Page 52
FS4100 I/O Module Configuration The Adaptec FS4100 I /O module. FS4500 I/O Module Configuration Use the Spheras RAIDWatch software application included on page 3-3 for software documentation. Drive Carrier LEDs Each drive carrier has three ... (has 87% or more original charge capacity) SATA I/O Module Configuration This section describes how to configure the two I/O modules. See Drive Carrier LEDs on your Adaptec Storage Enclosure CD to the Adaptec Storage Enclosure CD for detailed information about LED functions. 5-7 Refer to configure the...
FS4100 I/O Module Configuration The Adaptec FS4100 I /O module. FS4500 I/O Module Configuration Use the Spheras RAIDWatch software application included on page 3-3 for software documentation. Drive Carrier LEDs Each drive carrier has three ... (has 87% or more original charge capacity) SATA I/O Module Configuration This section describes how to configure the two I/O modules. See Drive Carrier LEDs on your Adaptec Storage Enclosure CD to the Adaptec Storage Enclosure CD for detailed information about LED functions. 5-7 Refer to configure the...
User Guide
Page 53
About the Fibre Channel Storage Enclosure 6-2 LIO JBOD Module Configurations 6-6 2 Gb/sec Operation 6-7 Daisy-chaining FC Storage Enclosures 6-7 LIO Module LEDs 6-7 Option Slot Loop AL_PA Assignments 6-7 Storage Enclosure LEDs 6-8 This chapter introduces the Adaptec FC4100 Storage Enclosure and describes how to cable and configure it as part of a complete storage subsystem. 6-1 6 Fibre Channel Storage Enclosures (FC4100) In this Chapter....
About the Fibre Channel Storage Enclosure 6-2 LIO JBOD Module Configurations 6-6 2 Gb/sec Operation 6-7 Daisy-chaining FC Storage Enclosures 6-7 LIO Module LEDs 6-7 Option Slot Loop AL_PA Assignments 6-7 Storage Enclosure LEDs 6-8 This chapter introduces the Adaptec FC4100 Storage Enclosure and describes how to cable and configure it as part of a complete storage subsystem. 6-1 6 Fibre Channel Storage Enclosures (FC4100) In this Chapter....
User Guide
Page 54
... The two APC modules in Figure 6-1. The LIO modules are a combination of each set. See Drive Slot Numbers on it is used for FC JBOD applications, and has two connectors on page 1-5 for the location of an LRC3 module and a copper or optical module. The LIO... JBOD module is possible to spin up first, followed by drives 4-6, drives 7-9 and drives 10-12, with a 6-second delay between each drive slot. If one . I/O Modules The Adaptec FC Storage Enclosure can accommodate two LIO modules, although it , labelled ...
... The two APC modules in Figure 6-1. The LIO modules are a combination of each set. See Drive Slot Numbers on it is used for FC JBOD applications, and has two connectors on page 1-5 for the location of an LRC3 module and a copper or optical module. The LIO... JBOD module is possible to spin up first, followed by drives 4-6, drives 7-9 and drives 10-12, with a 6-second delay between each drive slot. If one . I/O Modules The Adaptec FC Storage Enclosure can accommodate two LIO modules, although it , labelled ...
User Guide
Page 58
Quad Loop Operation The LIO module allows for a redundant data path to maintain proper airflow and cooling. This mode is initiated by your Adaptec FC Storage Enclosure. In this mode, the Input port forms a loop using drives 1 through 7. In dual loop operation, both loops flow in ... Loop (Nonredundant) Operation One LIO and the ES module are used for dual FC loop operations. Fibre Channel Storage Enclosures (FC4100) LIO JBOD Module Configurations This section describes the FC configurations supported by setting a switch in location S1 on the right.) Dual Loop Operation Two LIO ...
Quad Loop Operation The LIO module allows for a redundant data path to maintain proper airflow and cooling. This mode is initiated by your Adaptec FC Storage Enclosure. In this mode, the Input port forms a loop using drives 1 through 7. In dual loop operation, both loops flow in ... Loop (Nonredundant) Operation One LIO and the ES module are used for dual FC loop operations. Fibre Channel Storage Enclosures (FC4100) LIO JBOD Module Configurations This section describes the FC configurations supported by setting a switch in location S1 on the right.) Dual Loop Operation Two LIO ...
User Guide
Page 62
...drives 1-6 approximately 15 seconds later. I/O Modules The Adaptec SC4100 Storage Enclosure has two I/O modules available-the Adaptec JBOD I /O module slots. Connector LED Connector LED Module Fault LED VHDCI SCSI Connectors Figure 7-1 SCSI JBOD Connectors and LEDs SCSI JBOD I /O module provides two very high-density cable ... blinking, the I/O module is communicating with VHDCI cables. If one SCSI JBOD I/ O module, which can be located in either of each drive slot. The SCSI JBOD I /O Module LEDs The Adaptec SC4100 has three LEDs, shown in Figure 7-1. The two Connector LEDs are...
...drives 1-6 approximately 15 seconds later. I/O Modules The Adaptec SC4100 Storage Enclosure has two I/O modules available-the Adaptec JBOD I /O module slots. Connector LED Connector LED Module Fault LED VHDCI SCSI Connectors Figure 7-1 SCSI JBOD Connectors and LEDs SCSI JBOD I /O module provides two very high-density cable ... blinking, the I/O module is communicating with VHDCI cables. If one SCSI JBOD I/ O module, which can be located in either of each drive slot. The SCSI JBOD I /O Module LEDs The Adaptec SC4100 has three LEDs, shown in Figure 7-1. The two Connector LEDs are...
User Guide
Page 64
... host or to the I /O blank must install carrier blanks in the enclosure. Ultra320 SCSI Storage Enclosures Ultra320 SCSI Split-bus Configurations Note: The Ultra320 Storage Enclosure does not support daisychaining JBOD shelves. Split-bus SCSI IDs The Ultra320 SCSI Storage Enclosure's SCSI IDs are not populating all drive slots on the enclosure, you are hard set...
... host or to the I /O blank must install carrier blanks in the enclosure. Ultra320 SCSI Storage Enclosures Ultra320 SCSI Split-bus Configurations Note: The Ultra320 Storage Enclosure does not support daisychaining JBOD shelves. Split-bus SCSI IDs The Ultra320 SCSI Storage Enclosure's SCSI IDs are not populating all drive slots on the enclosure, you are hard set...
User Guide
Page 68
... tower configurations) ■ Up to 12 drives per enclosure Redundant Components ■ Two Advanced Power and Cooling (APC) units ■ Up to two RAID or JBOD controllers (depending on interface) ■ Two independent AC power cords ■ Up to 60 lbs (27 kg) maximum (with all drives installed) 8-2 redundant) Storage Enclosure...
... tower configurations) ■ Up to 12 drives per enclosure Redundant Components ■ Two Advanced Power and Cooling (APC) units ■ Up to two RAID or JBOD controllers (depending on interface) ■ Two independent AC power cords ■ Up to 60 lbs (27 kg) maximum (with all drives installed) 8-2 redundant) Storage Enclosure...
User Guide
Page 73
... LVD and Ultra-2 LVD SCSI bus modes. Cable Lengths Supported The external cable lengths supported for the Adaptec U320 Storage Enclosure are connected to...Adaptec sales representative for up-to twelve drives. This results in the Serial ATA specification. ■ Support for a rotational velocities of the SCSI I /O - Note: Hot-swapping of 5400, 7200, 10K, and 15K rpm... Note: Daisy-chaining JBOD shelves together is not supported. Split Bus-An I/O module can be located in either I /O - Technical Specifications I/O Module Configurations The Adaptec SCSI Storage Enclosure supports the...
... LVD and Ultra-2 LVD SCSI bus modes. Cable Lengths Supported The external cable lengths supported for the Adaptec U320 Storage Enclosure are connected to...Adaptec sales representative for up-to twelve drives. This results in the Serial ATA specification. ■ Support for a rotational velocities of the SCSI I /O - Note: Hot-swapping of 5400, 7200, 10K, and 15K rpm... Note: Daisy-chaining JBOD shelves together is not supported. Split Bus-An I/O module can be located in either I /O - Technical Specifications I/O Module Configurations The Adaptec SCSI Storage Enclosure supports the...