User Manual 1
Page 2
TABLE OF CONTENTS Introduction ...3 Installation Guide ...6 Web Interface ...10 Command Line Interface 35 Reset to Factory Default Setting / Recover from a Lost Password 53 RMCARD Firmware Upgrade 54 Save and Restore Configuration Settings 59 Troubleshooting ...60 Conformance Approvals 61 Appendix 1: IP Address Identification for CyberPower Remote Management Card 62 Appendix 2: How to Configure a RMCARD User Account in Authentication Servers 64 Appendix 3: UPS Firmware Upgrade 65 Appendix 4: Software Support 66 Appendix 5: RMCARD Adapter Guide 68
TABLE OF CONTENTS Introduction ...3 Installation Guide ...6 Web Interface ...10 Command Line Interface 35 Reset to Factory Default Setting / Recover from a Lost Password 53 RMCARD Firmware Upgrade 54 Save and Restore Configuration Settings 59 Troubleshooting ...60 Conformance Approvals 61 Appendix 1: IP Address Identification for CyberPower Remote Management Card 62 Appendix 2: How to Configure a RMCARD User Account in Authentication Servers 64 Appendix 3: UPS Firmware Upgrade 65 Appendix 4: Software Support 66 Appendix 5: RMCARD Adapter Guide 68
User Manual 1
Page 5
Link Indicator LED Status Indicators Link LED Off On (Yellow) Tx/Rx LED Off On (Green) Flashing (Green) Condition The Remote Management Card is not connected to the Network/ or the Remote Management Card power is off The Remote Management Card is connected to the Network The Remote Management Card power is off The Remote Management Card power is on - Receiving/transmitting data packet - Front Panel RMCARD205 RMCARD305 CyberPower Remote Management System 1. Universal Port 2. Tx/Rx Indicator 4. Reset finished 5 Ethernet Port 3.
Link Indicator LED Status Indicators Link LED Off On (Yellow) Tx/Rx LED Off On (Green) Flashing (Green) Condition The Remote Management Card is not connected to the Network/ or the Remote Management Card power is off The Remote Management Card is connected to the Network The Remote Management Card power is off The Remote Management Card power is on - Receiving/transmitting data packet - Front Panel RMCARD205 RMCARD305 CyberPower Remote Management System 1. Universal Port 2. Tx/Rx Indicator 4. Reset finished 5 Ethernet Port 3.
User Manual 1
Page 10
... Definition Display the current operating condition of the current UPS battery capacity. The name given to the interface, and can change any settings. Web Interface CyberPower Remote Management System Login User Account You will be asked to a preferred language. [Summary] Provide an overview of the system operation and the items that...: cyber 2. The person to the UPS. Graph of the current humidity reading of time the UPS can access read only features but cannot change to reset a username and password upon the first login. There are auto refreshed;
... Definition Display the current operating condition of the current UPS battery capacity. The name given to the interface, and can change any settings. Web Interface CyberPower Remote Management System Login User Account You will be asked to a preferred language. [Summary] Provide an overview of the system operation and the items that...: cyber 2. The person to the UPS. Graph of the current humidity reading of time the UPS can access read only features but cannot change to reset a username and password upon the first login. There are auto refreshed;
User Manual 1
Page 16
...is recommended to a "Reboot UPS", "Turn UPS off . This prevents excessive power consumption caused by all PowerPanel® Remote shundown +2 minutes. Resets the pending action to warn PowerPanel® Business Remote before it turns off in UPS -> PowerPanel List. Amount of the UPS to insure a ...changed to be on Turns the UPS off , Reboot Duration defines how long the UPS waits before turning the UPS off . CyberPower Remote Management System Over Discharge Protection Enter Sleep Mode After All Remote Shutdown Non-Critical Outlet Bank Turn Off Threshold Turn off this ...
...is recommended to a "Reboot UPS", "Turn UPS off . This prevents excessive power consumption caused by all PowerPanel® Remote shundown +2 minutes. Resets the pending action to warn PowerPanel® Business Remote before it turns off in UPS -> PowerPanel List. Amount of the UPS to insure a ...changed to be on Turns the UPS off , Reboot Duration defines how long the UPS waits before turning the UPS off . CyberPower Remote Management System Over Discharge Protection Enter Sleep Mode After All Remote Shutdown Non-Critical Outlet Bank Turn Off Threshold Turn off this ...
User Manual 1
Page 18
...entries. 18 Click [Once], [Daily] or [Weekly] option and Click "Next>>", Enter the date and time to default settings.. 3. Click "Reset" to return to shut down the UPS. Select the bank to be controlled, and click "Shutdown Clients" to set one time event for ...The result will be reported after the runtime estimation is done. Item Runtime Estimation Estimated Runtime Last Estimation Result Last Estimation Date CyberPower Remote Management System Definition batteries will then be recharged automatically after the estimation is finished or canceled The estimated runtime of the ...
...entries. 18 Click [Once], [Daily] or [Weekly] option and Click "Next>>", Enter the date and time to default settings.. 3. Click "Reset" to return to shut down the UPS. Select the bank to be controlled, and click "Shutdown Clients" to set one time event for ...The result will be reported after the runtime estimation is done. Item Runtime Estimation Estimated Runtime Last Estimation Result Last Estimation Date CyberPower Remote Management System Definition batteries will then be recharged automatically after the estimation is finished or canceled The estimated runtime of the ...
User Manual 1
Page 22
...current UPS battery capacity. • Remaining Runtime: The estimated duration of time that the UPS can support the connected load in kWh. CyberPower Remote Management System [Logs->Event Logs] Display the list of events and a brief description of each event along with the date and ...utility power from the previous record. • Input max (V): The maximum input voltage of the energy used by the device since the last reset. however, different products may have the same definition as they are listed under "System->Notifications->Event Action." 2. Note: 1. The recordable events ...
...current UPS battery capacity. • Remaining Runtime: The estimated duration of time that the UPS can support the connected load in kWh. CyberPower Remote Management System [Logs->Event Logs] Display the list of events and a brief description of each event along with the date and ...utility power from the previous record. • Input max (V): The maximum input voltage of the energy used by the device since the last reset. however, different products may have the same definition as they are listed under "System->Notifications->Event Action." 2. Note: 1. The recordable events ...
User Manual 1
Page 33
... (TCP/IP Settings Reserved) Definition Restart the system without turning off or restart the UPS. 33 Reset the system to deliver the messages via SMS providers. For example: Address sample@cyberpower.com Subject TestSubject Content E_PHONE_NUMBER&text=E_MESSAGE [System->Notifications->SMS Recipients] Users can set up to factory default setting but reserving...
... (TCP/IP Settings Reserved) Definition Restart the system without turning off or restart the UPS. 33 Reset the system to deliver the messages via SMS providers. For example: Address sample@cyberpower.com Subject TestSubject Content E_PHONE_NUMBER&text=E_MESSAGE [System->Notifications->SMS Recipients] Users can set up to factory default setting but reserving...
User Manual 1
Page 43
... | all reserving TCP/IP settings, and restart it . location Set the location of RMCARD, reset RMCARD. contact Set the person to default setting and restart it . CyberPower > sys reset all system information for RMCARD Set name of system CyberPower > sys show name Argument Description Display all 43 all-Set all information of the...
... | all reserving TCP/IP settings, and restart it . location Set the location of RMCARD, reset RMCARD. contact Set the person to default setting and restart it . CyberPower > sys reset all system information for RMCARD Set name of system CyberPower > sys show name Argument Description Display all 43 all-Set all information of the...
User Manual 1
Page 53
... the retaining screws. 53 Remove the card again. 6. CyberPower Remote Management System Reset to Factory Default Setting / Recover from a Lost Password To reset the CyberPower Remote Management Card to its factory default setting (including web log-in user name and password), please following these steps: RMCARD205 RMCARD305 1. Do not dispose of the ON/OFF flashing...
... the retaining screws. 53 Remove the card again. 6. CyberPower Remote Management System Reset to Factory Default Setting / Recover from a Lost Password To reset the CyberPower Remote Management Card to its factory default setting (including web log-in user name and password), please following these steps: RMCARD205 RMCARD305 1. Do not dispose of the ON/OFF flashing...
User Manual 1
Page 60
.... If green LED is off : method 2 ►Ensure the network connection is on . Lost the user name and Please refer to the "Reset to the card via CLI (Telnet or SSH client). Ensure the IP address of gateway. Ensure the Jumper on a different network subnet from password ... and green LEDs are both on the same local network subnet as the CyberPower device you can ping the RMCARD. CyberPower Remote Management System Troubleshooting Problem Solution 1. Check the LED status, it is on the Reset Pin is enabled by logging in to Factory Default Setting / Recover from ...
.... If green LED is off : method 2 ►Ensure the network connection is on . Lost the user name and Please refer to the "Reset to the card via CLI (Telnet or SSH client). Ensure the IP address of gateway. Ensure the Jumper on a different network subnet from password ... and green LEDs are both on the same local network subnet as the CyberPower device you can ping the RMCARD. CyberPower Remote Management System Troubleshooting Problem Solution 1. Check the LED status, it is on the Reset Pin is enabled by logging in to Factory Default Setting / Recover from ...
Quick Start Guide
Page 3
Table of Contents INTRODUCTION 1 Overview 1 System Requirements 1 Unpacking 1 Front Panel 2 LED Status Indicator 2 INSTALLATION 3 Step 1. Configure the IP Address 4 WEB INTERFACE 6 Login User Account 6 FIRMWARE UPGRADE 6 Using Upgrade and Configuration Utility Tool ....7 RESET TO FACTORY DEFAULT SETTING/ RECOVER FROM A LOST PASSWORD 10 RMCARD ADAPTER GUIDE 1 1 SOFTWARE SUPPORT 13 TROUBLESHOOTING 14 CONFORMANCE APPROVALS 15 i Hardware Installation 3 Step 2.
Table of Contents INTRODUCTION 1 Overview 1 System Requirements 1 Unpacking 1 Front Panel 2 LED Status Indicator 2 INSTALLATION 3 Step 1. Configure the IP Address 4 WEB INTERFACE 6 Login User Account 6 FIRMWARE UPGRADE 6 Using Upgrade and Configuration Utility Tool ....7 RESET TO FACTORY DEFAULT SETTING/ RECOVER FROM A LOST PASSWORD 10 RMCARD ADAPTER GUIDE 1 1 SOFTWARE SUPPORT 13 TROUBLESHOOTING 14 CONFORMANCE APPROVALS 15 i Hardware Installation 3 Step 2.
Quick Start Guide
Page 5
Reset finished 2 Universal Port 2. Link Indicator 43 LED Status Indicators Link LED Condition The Remote Management Card is not O connected to the Network / or the ... Remote Management Card power is o On (Green) The Remote Management Card power is on Flashing (Green) - Tx/Rx Indicator 4. Receiving/transmitting data packet - Front Panel RMCARD205 RMCARD205 1 2 Universal Link Tx/Rx 3 4 RMCARD305 RMCARD305 1 2 Universal Link Tx/Rx 1. Ethernet Port 3.
Reset finished 2 Universal Port 2. Link Indicator 43 LED Status Indicators Link LED Condition The Remote Management Card is not O connected to the Network / or the ... Remote Management Card power is o On (Green) The Remote Management Card power is on Flashing (Green) - Tx/Rx Indicator 4. Receiving/transmitting data packet - Front Panel RMCARD205 RMCARD205 1 2 Universal Link Tx/Rx 3 4 RMCARD305 RMCARD305 1 2 Universal Link Tx/Rx 1. Ethernet Port 3.
Quick Start Guide
Page 9
....bin NOTE: Please do not turn the UPS/ATS PDU o when processing the Firmware upgrade. 6 WEB INTERFACE Login User Account You will be asked to reset a username and password upon the first login. Administrator - B. The administrator can select a preferred language after login. You can obtain both the new features and...
....bin NOTE: Please do not turn the UPS/ATS PDU o when processing the Firmware upgrade. 6 WEB INTERFACE Login User Account You will be asked to reset a username and password upon the first login. Administrator - B. The administrator can select a preferred language after login. You can obtain both the new features and...
Quick Start Guide
Page 13
... as illustrated. Place the jumper back onto the Reset pins. 7. RESET TO FACTORY DEFAULT SETTING/RECOVER FROM A LOST PASSWORD To reset the CyberPower Remote Management Card to its factory default setting (including web log-in user name and password), please follow these steps: RESET JUMPER RMCARD205 RESET JUMPER RMCARD305 1. Install card into the expansion port on the...
... as illustrated. Place the jumper back onto the Reset pins. 7. RESET TO FACTORY DEFAULT SETTING/RECOVER FROM A LOST PASSWORD To reset the CyberPower Remote Management Card to its factory default setting (including web log-in user name and password), please follow these steps: RESET JUMPER RMCARD205 RESET JUMPER RMCARD305 1. Install card into the expansion port on the...
Quick Start Guide
Page 17
...installed. Ensure the Jumper on a di erent network. 14 Lost the user name and password Please refer to the "Reset to communicate with. 3. Ensure you are configured correctly. 2. Ensure the IP address of gateway is con... the PC being used is on a di erent network subnet from a Lost Password" section. Ensure you are on the Reset Pin is on . Unable to the card via CLI (Telnet or SSH client). Unable to ping the Remote Management Card...the yellow and green LEDs are both on the same local network subnet as the CyberPower device you can ping the RMCARD. 2.
...installed. Ensure the Jumper on a di erent network. 14 Lost the user name and password Please refer to the "Reset to communicate with. 3. Ensure you are configured correctly. 2. Ensure the IP address of gateway is con... the PC being used is on a di erent network subnet from a Lost Password" section. Ensure you are on the Reset Pin is on . Unable to the card via CLI (Telnet or SSH client). Unable to ping the Remote Management Card...the yellow and green LEDs are both on the same local network subnet as the CyberPower device you can ping the RMCARD. 2.