for model ER48D) by removing the conduit bracket inside the range electrical access box. When installing an appliance cord on models equipped for use in Canada is ¼" (6.4mm) larger than those stated. www.Dacor.com Phone: (800) 793-0093 5.10 ... and L2), one neutral, one ground GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure 1/2 p.s.i. ELECTRICAL ACCESS DIMENSIONS Model A B C D E* ER36D 5 5/8" (142.9 mm)...
for model ER48D) by removing the conduit bracket inside the range electrical access box. When installing an appliance cord on models equipped for use in Canada is ¼" (6.4mm) larger than those stated. www.Dacor.com Phone: (800) 793-0093 5.10 ... and L2), one neutral, one ground GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Manifold Pressure Minimum Gas Supply Pressure Natural Gas 5" Water Column 6" Water Column Propane (LP) 10" Water Column 11" Water Column * Maximum gas supply pressure 1/2 p.s.i. ELECTRICAL ACCESS DIMENSIONS Model A B C D E* ER36D 5 5/8" (142.9 mm)...
Installation Instructions
Page 5
... To prevent damage, remove the meat probe from breakage caused by high oven temperatures or mechanical shock. Pacific Time Web site: www.Dacor.com Dacor Distinctive Service (for high altitude operation, 4000 ft. (1219 m) and up during cooking. Objects left on the bottom of the ... warning • For your Dacor dealer or the Dacor Customer Service Team. on the bottom of the oven(s). and Canada) Monday - Whenever you have the model and serial number of the appliance ready. and Canada) Monday - Friday 6:00 a.m. GAS TYPE NG = Natural Gas LP = Liquid Petroleum (Propane) ...
... To prevent damage, remove the meat probe from breakage caused by high oven temperatures or mechanical shock. Pacific Time Web site: www.Dacor.com Dacor Distinctive Service (for high altitude operation, 4000 ft. (1219 m) and up during cooking. Objects left on the bottom of the ... warning • For your Dacor dealer or the Dacor Customer Service Team. on the bottom of the oven(s). and Canada) Monday - Whenever you have the model and serial number of the appliance ready. and Canada) Monday - Friday 6:00 a.m. GAS TYPE NG = Natural Gas LP = Liquid Petroleum (Propane) ...
Installation Instructions
Page 6
...installed by a licensed electrician according NEMA 14-50R Receptacle to the above 4000 ft. (1219 m) make sure it is equipped for model ER48D ◊ Include a strain relief ◊ Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends ... GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Minimum Minimum Gas Manifold Pressure Supply Pressure** Natural Gas 5" Water Column 6" Water Column Liquid Propane (LP) 10" Water Column 11" Water Column * The gas supply pressure for testing the regulator setting shall be at an altitude above specifications....
...installed by a licensed electrician according NEMA 14-50R Receptacle to the above 4000 ft. (1219 m) make sure it is equipped for model ER48D ◊ Include a strain relief ◊ Be terminated by tinned leads, closed loop terminals or open ended spade lugs with upturned ends ... GAS SUPPLY PRESSURE REQUIREMENTS* Gas Type Minimum Minimum Gas Manifold Pressure Supply Pressure** Natural Gas 5" Water Column 6" Water Column Liquid Propane (LP) 10" Water Column 11" Water Column * The gas supply pressure for testing the regulator setting shall be at an altitude above specifications....
Installation Instructions
Page 17
...to avoid a fire or explosion hazard. Do not use Teflon tape or plumber's putty on gas flex line connections. • For LP installations, the LP gas tank must be isolated from the gas supply piping by closing the shut-off . 2. Regulator connection Back of the gas line ... the appliance. Consult your dealer if the range is off valve during any pressure testing exceeding 1/2 p.s.i. (3.5 kPa). • The range must have "LP" as instructed to the regulator must never exceed 1/2 pound per square inch (p.s.i.) or 3.5kPa. • The range and shut-off position and that...
...to avoid a fire or explosion hazard. Do not use Teflon tape or plumber's putty on gas flex line connections. • For LP installations, the LP gas tank must be isolated from the gas supply piping by closing the shut-off . 2. Regulator connection Back of the gas line ... the appliance. Consult your dealer if the range is off valve during any pressure testing exceeding 1/2 p.s.i. (3.5 kPa). • The range must have "LP" as instructed to the regulator must never exceed 1/2 pound per square inch (p.s.i.) or 3.5kPa. • The range and shut-off position and that...
Installation Instructions
Page 20
... Operation Before operating the range, read the accompanying use with all remaining burners. Press START. 5. If ignition does not occur within 6 seconds). Dacor's Smart Flame™ feature reduces the flame under the grate fingers to the OFF position. 12. Repeat the ignition test for the cost of ...See page 15. □□ Is the oven door properly installed according to ensure that it counterclockwise to these instructions and in accordance with LP gas, the ends of the flame may take up to four seconds for at least five minutes to allow any gas to occur, at...
... Operation Before operating the range, read the accompanying use with all remaining burners. Press START. 5. If ignition does not occur within 6 seconds). Dacor's Smart Flame™ feature reduces the flame under the grate fingers to the OFF position. 12. Repeat the ignition test for the cost of ...See page 15. □□ Is the oven door properly installed according to ensure that it counterclockwise to these instructions and in accordance with LP gas, the ends of the flame may take up to four seconds for at least five minutes to allow any gas to occur, at...
Use & Care Manuals
Page 3
... to the use this appliance. To minimize exposure to these substances, always operate this or any other than warranty questions) call: Dacor Customer Service (800) 793-0093 (U.S.A. Important Safety Instructions Installer: Leave these instructions with gas. Use common sense and caution when installing... questions (other appliance. If you have any slots, holes or passages in Canada No character = Equipped for U.S.A GAS TYPE NG = Natural gas LP = Liquid petroleum (propane) ALTITUDE H = Equipped for high altitude operation, 4000 ft. (1219 m) and up No character = Equipped for low ...
... to the use this appliance. To minimize exposure to these substances, always operate this or any other than warranty questions) call: Dacor Customer Service (800) 793-0093 (U.S.A. Important Safety Instructions Installer: Leave these instructions with gas. Use common sense and caution when installing... questions (other appliance. If you have any slots, holes or passages in Canada No character = Equipped for U.S.A GAS TYPE NG = Natural gas LP = Liquid petroleum (propane) ALTITUDE H = Equipped for high altitude operation, 4000 ft. (1219 m) and up No character = Equipped for low ...
Use & Care Manuals
Page 13
... utensil for Service section on the ends of the flames are acid-resistant but not acid-proof. Use cookware that they cannot be reduced by Dacor 's Smart Flame feature. Push in on the grate. • To avoid burns or fire hazard, reduce the flame level if it lights. The igniter for... also spark automatically if the flame is not spread evenly around the perimeter of the grates, spill trays, and burner caps are normal when using LP gas. 3. The igniter will also warm up the sides of the utensil is potentially dangerous. Eliminate any burner cap, burner base or igniter while the...
... utensil for Service section on the ends of the flames are acid-resistant but not acid-proof. Use cookware that they cannot be reduced by Dacor 's Smart Flame feature. Push in on the grate. • To avoid burns or fire hazard, reduce the flame level if it lights. The igniter for... also spark automatically if the flame is not spread evenly around the perimeter of the grates, spill trays, and burner caps are normal when using LP gas. 3. The igniter will also warm up the sides of the utensil is potentially dangerous. Eliminate any burner cap, burner base or igniter while the...
Use & Care Manuals
Page 34
... low. Check to make sure that the range is off . Contact power company. See Operating the Cooktop section for the type of gas (Natural or LP) or set up to 60 seconds when cold and set up for more information on how to spark for up for different altitude. Clean and...
... low. Check to make sure that the range is off . Contact power company. See Operating the Cooktop section for the type of gas (Natural or LP) or set up to 60 seconds when cold and set up for more information on how to spark for up for different altitude. Clean and...