Fluke 1750 Three Phase Power Recorder Datasheet
Page 1
...triggering capture every measurement, on every channel, every time. • Intuitive PC software: Easily analyze data and generate reports. Fluke 1750 Three-Phase Power Recorder Technical Data Never miss capturing a disturbance-with IEC61000-4-30 standards for correct evaluation of even the shortest ...test locations. • Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to incorrect set-up in minutes with the Fluke 1750 Power Recorder. Capture every measurement, every event, on three phases, neutral, and ...
...triggering capture every measurement, on every channel, every time. • Intuitive PC software: Easily analyze data and generate reports. Fluke 1750 Three-Phase Power Recorder Technical Data Never miss capturing a disturbance-with IEC61000-4-30 standards for correct evaluation of even the shortest ...test locations. • Threshold-free setup: Apply thresholds after data is collected with Fluke Power Analyze Software so there is no need to incorrect set-up in minutes with the Fluke 1750 Power Recorder. Capture every measurement, every event, on three phases, neutral, and ...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 2
The Fluke 1750 has an exclusive capture algorithm which makes certain all events are captured without the tedious setups and blind spots associated with wireless PDA interface. The ... quick setups. no more uncertainty that the recorder is being recorded. Once power is applied the instrument automatically begins recording and LEDs give you . 2 Fluke Corporation Fluke 1750 Three-Phase Power Recorder No need for a laptop computer (laptops can also be used when desired). Applications Long-term analysis: Uncover hard-to reconnect wires...
The Fluke 1750 has an exclusive capture algorithm which makes certain all events are captured without the tedious setups and blind spots associated with wireless PDA interface. The ... quick setups. no more uncertainty that the recorder is being recorded. Once power is applied the instrument automatically begins recording and LEDs give you . 2 Fluke Corporation Fluke 1750 Three-Phase Power Recorder No need for a laptop computer (laptops can also be used when desired). Applications Long-term analysis: Uncover hard-to reconnect wires...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 3
Thresholds for each channel to flag in the data stream. Voice, data, and picture annotations can be made . 3 Fluke Corporation Fluke 1750 Three-Phase Power Recorder Imagine being able to the 50th harmonic. Events can be displayed against a variety of two quick and easy options: download the ...
Thresholds for each channel to flag in the data stream. Voice, data, and picture annotations can be made . 3 Fluke Corporation Fluke 1750 Three-Phase Power Recorder Imagine being able to the 50th harmonic. Events can be displayed against a variety of two quick and easy options: download the ...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 4
...to data after the data is recorded! Simplified report writer feature included in a low-voltage power distribution system. 4 Fluke Corporation Fluke 1750 Three-Phase Power Recorder They are the first tools of standard or customized templates. And the easy-to-use in ...V CAT III safety rating Designed to help protect you want The new Fluke Power Analyze software revolutionizes your equipment, the Fluke 1750 Three-Phase Power Recorder and accessories are measured and calculated consistently with Fluke Power Analyze, thresholds can be modified after collection using a variety of ...
...to data after the data is recorded! Simplified report writer feature included in a low-voltage power distribution system. 4 Fluke Corporation Fluke 1750 Three-Phase Power Recorder They are the first tools of standard or customized templates. And the easy-to-use in ...V CAT III safety rating Designed to help protect you want The new Fluke Power Analyze software revolutionizes your equipment, the Fluke 1750 Three-Phase Power Recorder and accessories are measured and calculated consistently with Fluke Power Analyze, thresholds can be modified after collection using a variety of ...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 5
... SEAT LICENSE • One additional license for installation on and flexi-CT's are specially designed to work seamlessly with rollers Miscellaneous 1750/MC • Additional SD Memory Card for Fluke 1750 1750/SEAT-L • Fluke Power Analyze - Current Range 2 A to 100 A 20 A to 1000 A 100 A to 5000 A 100 A to 5000 A Accuracy 1 % rdg ± 0.5 % FS 1 % rdg...
... SEAT LICENSE • One additional license for installation on and flexi-CT's are specially designed to work seamlessly with rollers Miscellaneous 1750/MC • Additional SD Memory Card for Fluke 1750 1750/SEAT-L • Fluke Power Analyze - Current Range 2 A to 100 A 20 A to 1000 A 100 A to 5000 A 100 A to 5000 A Accuracy 1 % rdg ± 0.5 % FS 1 % rdg...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 6
... time control Automatic Maximum number of events Limited only by the size of the internal memory Power requirements 100 to 100 % of current sensor range 6 Fluke Corporation Fluke 1750 Three-Phase Power Recorder
... time control Automatic Maximum number of events Limited only by the size of the internal memory Power requirements 100 to 100 % of current sensor range 6 Fluke Corporation Fluke 1750 Three-Phase Power Recorder
Fluke 1750 Three Phase Power Recorder Datasheet
Page 7
...) Displayed data Amplitude and duration of swell Measurement uncertainty Same as voltage dip Power Measurements Calculated per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt) 7 Fluke Corporation Fluke 1750 Three-Phase Power Recorder Transient voltage (impulse) Measurement type Full scale Sample resolution Measurement uncertainty Waveshape sampling 8000 V pk 200 nS ± 5 % reading ±...
...) Displayed data Amplitude and duration of swell Measurement uncertainty Same as voltage dip Power Measurements Calculated per EN 61000-4-15:2003: 10 min (Pst), 2 h (Plt) 7 Fluke Corporation Fluke 1750 Three-Phase Power Recorder Transient voltage (impulse) Measurement type Full scale Sample resolution Measurement uncertainty Waveshape sampling 8000 V pk 200 nS ± 5 % reading ±...
Fluke 1750 Three Phase Power Recorder Datasheet
Page 8
...input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V) Ordering information Fluke-1750 Three-Phase Power Recorder Includes: • 1750 acquisition unit • PDA wireless "front panel interface" and charger power plug adapters • 4 - 400 A current ... • Color localization set of products offers the highest level of performance and maintains the Fluke promise of rugged and reliable test tools. 8 Fluke Corporation Fluke 1750 Three-Phase Power Recorder To learn more information call: In the U.S.A. (800) 443-5853...
...input unit: Contamination Level 2, Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V) Ordering information Fluke-1750 Three-Phase Power Recorder Includes: • 1750 acquisition unit • PDA wireless "front panel interface" and charger power plug adapters • 4 - 400 A current ... • Color localization set of products offers the highest level of performance and maintains the Fluke promise of rugged and reliable test tools. 8 Fluke Corporation Fluke 1750 Three-Phase Power Recorder To learn more information call: In the U.S.A. (800) 443-5853...
Fluke 1750 Calibration Manual
Page 9
... Introduction XW Warning To avoid electric shock or personal injury, do so. The 1750 Calibration Manual provides the following information: • Precautions and safety information • Specifications • Basic maintenance • Calibration procedures • Verification ...do not perform the calibration verification tests or calibration procedures described in the world Or, visit Fluke's Web site at www.fluke.com To register your product, visit http://register.fluke.com 1 Contacting Fluke To contact Fluke, call: 1-888-993-5853 in USA 1-800-363-5853 in Canada +31-402-675...
... Introduction XW Warning To avoid electric shock or personal injury, do so. The 1750 Calibration Manual provides the following information: • Precautions and safety information • Specifications • Basic maintenance • Calibration procedures • Verification ...do not perform the calibration verification tests or calibration procedures described in the world Or, visit Fluke's Web site at www.fluke.com To register your product, visit http://register.fluke.com 1 Contacting Fluke To contact Fluke, call: 1-888-993-5853 in USA 1-800-363-5853 in Canada +31-402-675...
Fluke 1750 Calibration Manual
Page 10
... and observe all probes, test leads, and accessories that are used for calibration. There are present. 1750 Calibration Manual To contact Technical Support: fpqsupport@fluke.com or 888-257-9897 (US only) Safety Information The 1750 Power Recorder (hereafter referred to as specified in this manual unless you are qualified to do so...
... and observe all probes, test leads, and accessories that are used for calibration. There are present. 1750 Calibration Manual To contact Technical Support: fpqsupport@fluke.com or 888-257-9897 (US only) Safety Information The 1750 Power Recorder (hereafter referred to as specified in this manual unless you are qualified to do so...
Fluke 1750 Calibration Manual
Page 14
...For a list of required equipment for repair. Contact an authorized Fluke service center for the verification tests and calibration adjustment, see Tables 2 and 3. 1750 Calibration Manual Environmental and Safety Specifications Operating Environment indoors or in covered...: ± 0.03 % Ohms Range: 100 KΩ Accuracy: ± 0.011 % 1750 Cal Wizard and Fluke Power Analyze software installed Recommended Model Fluke 5520A Multi-Product Calibrator or equivalent Fluke 8846A Precision Multimeter or equivalent 6 Periodically wipe the case with 4-wire Ohms Personal Computer (PC...
...For a list of required equipment for repair. Contact an authorized Fluke service center for the verification tests and calibration adjustment, see Tables 2 and 3. 1750 Calibration Manual Environmental and Safety Specifications Operating Environment indoors or in covered...: ± 0.03 % Ohms Range: 100 KΩ Accuracy: ± 0.011 % 1750 Cal Wizard and Fluke Power Analyze software installed Recommended Model Fluke 5520A Multi-Product Calibrator or equivalent Fluke 8846A Precision Multimeter or equivalent 6 Periodically wipe the case with 4-wire Ohms Personal Computer (PC...
Fluke 1750 Calibration Manual
Page 16
For service, see Contacting Fluke. Apply power to display the channels as L1, L2, and L3 instead of the scope display. Select 1750 Live, then Scope. 6. Make sure the correct items are used to the Recorder front panel. Note Power Analyze can be ...personnel. The following tests are qualified to the Scope button. 5. If the Recorder fails any of the Recorder. AC Voltage Accuracy Verification 1. 1750 Calibration Manual Verification Tests XWWarning To avoid electrical shock, personal injury, or fire: • Do not perform the calibration procedures or calibration ...
For service, see Contacting Fluke. Apply power to display the channels as L1, L2, and L3 instead of the scope display. Select 1750 Live, then Scope. 6. Make sure the correct items are used to the Recorder front panel. Note Power Analyze can be ...personnel. The following tests are qualified to the Scope button. 5. If the Recorder fails any of the Recorder. AC Voltage Accuracy Verification 1. 1750 Calibration Manual Verification Tests XWWarning To avoid electrical shock, personal injury, or fire: • Do not perform the calibration procedures or calibration ...
Fluke 1750 Calibration Manual
Page 23
... calibration procedure, with the Recorder over Ethernet. Connect the Recorder and the PC to the network with an Ethernet cable. This can either be by 1750 Cal Wizard Software (Cal Wizard), which communicates with instructions for making cable connections, setting the correct sources, and finalizing the calibration. If necessary, run Ohms...
... calibration procedure, with the Recorder over Ethernet. Connect the Recorder and the PC to the network with an Ethernet cable. This can either be by 1750 Cal Wizard Software (Cal Wizard), which communicates with instructions for making cable connections, setting the correct sources, and finalizing the calibration. If necessary, run Ohms...
Fluke 1750 Operators Manual
Page 1
All product names are subject to change without notice. Specifications are trademarks of their respective companies. All rights reserved. 1750 Power Recorder Operators Manual October 2006 Rev.3, 11/10 © 2006-2010 Fluke Corporation.
All product names are subject to change without notice. Specifications are trademarks of their respective companies. All rights reserved. 1750 Power Recorder Operators Manual October 2006 Rev.3, 11/10 © 2006-2010 Fluke Corporation.
Fluke 1750 Operators Manual
Page 7
One Phase Plus Neutral 15 5. Three-Phase Delta 19 9. Power View Menu Tree 28 v Fluke 1750 Power Recorder 5 2. Three-Phase Wye 18 8. Three-Phase IT ...20 10. One-Phase Split Phase 17 7. Three-Phase High Leg 21 11. Applying the Front Panel Decal 7 3. Three-Phase Open Leg 22 12. 2-Element Delta ...23 13. 2 ½-Element Wye 24 14. One-Phase IT No Neutral 16 6. List of Figures Figure Title Page 1. Connecting the Supplemental Ground Terminal 8 4. Connecting to the Recorder 25 15.
One Phase Plus Neutral 15 5. Three-Phase Delta 19 9. Power View Menu Tree 28 v Fluke 1750 Power Recorder 5 2. Three-Phase Wye 18 8. Three-Phase IT ...20 10. One-Phase Split Phase 17 7. Three-Phase High Leg 21 11. Applying the Front Panel Decal 7 3. Three-Phase Open Leg 22 12. 2-Element Delta ...23 13. 2 ½-Element Wye 24 14. One-Phase IT No Neutral 16 6. List of Figures Figure Title Page 1. Connecting the Supplemental Ground Terminal 8 4. Connecting to the Recorder 25 15.
Fluke 1750 Operators Manual
Page 9
...PDA with the wireless link is about 5 meters (16 feet) from Fluke. Four 400 A current probes are available from the Recorder. Downloaded data goes onto the SD memory card plugged into the 1750, not directly to configure the Recorder, troubleshoot connections, preview data, or...approximately 5 minutes or less. 1 If a phase channel is a comprehensive yet easy to use PC application, Power Analyze. 1750 Power Recorder Introduction The Fluke 1750 Power Recorder is wired incorrectly, you can view live readings and a phasor diagram on current probes are provided as standard equipment ...
...PDA with the wireless link is about 5 meters (16 feet) from Fluke. Four 400 A current probes are available from the Recorder. Downloaded data goes onto the SD memory card plugged into the 1750, not directly to configure the Recorder, troubleshoot connections, preview data, or...approximately 5 minutes or less. 1 If a phase channel is a comprehensive yet easy to use PC application, Power Analyze. 1750 Power Recorder Introduction The Fluke 1750 Power Recorder is wired incorrectly, you can view live readings and a phasor diagram on current probes are provided as standard equipment ...
Fluke 1750 Operators Manual
Page 10
... help is called the "event detector" in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To contact Technical Support: fpqsupport@fluke.com or 888-257-9897 2 1750 Operators Manual • Automatic disturbance capture The Recorder uses an automatic, self-learning threshold...
... help is called the "event detector" in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To contact Technical Support: fpqsupport@fluke.com or 888-257-9897 2 1750 Operators Manual • Automatic disturbance capture The Recorder uses an automatic, self-learning threshold...
Fluke 1750 Operators Manual
Page 13
... panel is illustrated in Figure 1 and described in this manual. Power Recorder Features You can damage the Recorder. 5 Fluke 1750 Power Recorder azd09f.eps WCaution Connecting the supplemental ground terminal and the line cord safety ground to different ground potentials creates ...a ground loop that can also order the following optional accessories. For more information about accessories, see Contacting Fluke earlier in Table 3. 23 4 1 POWER 1750 POWER RECORDER VOLTAGE A B C N 100-240 V 47-63 Hz ON CURRENT SD ETHERNET LINK BUSY 5 6 13 12...
... panel is illustrated in Figure 1 and described in this manual. Power Recorder Features You can damage the Recorder. 5 Fluke 1750 Power Recorder azd09f.eps WCaution Connecting the supplemental ground terminal and the line cord safety ground to different ground potentials creates ...a ground loop that can also order the following optional accessories. For more information about accessories, see Contacting Fluke earlier in Table 3. 23 4 1 POWER 1750 POWER RECORDER VOLTAGE A B C N 100-240 V 47-63 Hz ON CURRENT SD ETHERNET LINK BUSY 5 6 13 12...
Fluke 1750 Operators Manual
Page 33
You can then use Fluke Power Analyze to a remote site when setting up the Recorder, view power measurements wherever the Recorder is installed, or download data from a PC directly using ... PDA with Power View Software Configure via RF Communication PC with the PDA using a wireless controller radio interface. Power View communicates with Power Analyze Software Fluke 1750 Power Recorder Direct Ethernet Connection Figure 14. With Power View installed on the PDA, you can alternatively connect to the Ethernet port on the PDA...
You can then use Fluke Power Analyze to a remote site when setting up the Recorder, view power measurements wherever the Recorder is installed, or download data from a PC directly using ... PDA with Power View Software Configure via RF Communication PC with the PDA using a wireless controller radio interface. Power View communicates with Power Analyze Software Fluke 1750 Power Recorder Direct Ethernet Connection Figure 14. With Power View installed on the PDA, you can alternatively connect to the Ethernet port on the PDA...
Fluke 1750 Operators Manual
Page 57
...and receiver. • Connect the equipment into an outlet on a circuit different from that may cause undesired operation of the device. The Fluke 1750 Power Recorder (wireless host) has been tested and found to comply with the limits for a Class A digital device, pursuant to Part... must be ≥20 cm (7.9 inches) during wireless communication. • FCC ID: T68FLK1750 or QOQWT 11 (see rear decal on Fluke 1750 for the appropriate ID). These limits are designed to radio communications. This device complies with the instruction manual, may cause harmful interference to provide...
...and receiver. • Connect the equipment into an outlet on a circuit different from that may cause undesired operation of the device. The Fluke 1750 Power Recorder (wireless host) has been tested and found to comply with the limits for a Class A digital device, pursuant to Part... must be ≥20 cm (7.9 inches) during wireless communication. • FCC ID: T68FLK1750 or QOQWT 11 (see rear decal on Fluke 1750 for the appropriate ID). These limits are designed to radio communications. This device complies with the instruction manual, may cause harmful interference to provide...