Fluke 1750 Three Phase Power Recorder Datasheet
Page 3
... on each channel and totals. Crosschannel current and voltage triggering captures event data on one of two quick and easy options: download the data onto the included SD memory EN50160 report delivers an easy to read pass or fail chart along with drill down ...to flag in the data stream. Powerful data management Data is automatically stored on the internal flash memory that can be made . 3 Fluke Corporation Fluke 1750 Three-Phase Power Recorder card without compression or overwriting. When periodic analysis of power quality, harmonics, power and energy. Events can store ...
... on each channel and totals. Crosschannel current and voltage triggering captures event data on one of two quick and easy options: download the data onto the included SD memory EN50160 report delivers an easy to read pass or fail chart along with drill down ...to flag in the data stream. Powerful data management Data is automatically stored on the internal flash memory that can be made . 3 Fluke Corporation Fluke 1750 Three-Phase Power Recorder card without compression or overwriting. When periodic analysis of power quality, harmonics, power and energy. Events can store ...
Fluke 1750 Calibration Manual
Page 21
... will all channels the same and set both AN and the NG thresholds to -last N-triggered Phase Absolute value in Table 8. 33. Press STBY on 1750 Download, and then Save. 23. Click on the calibrator. 20. Click on View Recorded, and then Events. 24. Starting from the CN Triggered Phase data. It...
... will all channels the same and set both AN and the NG thresholds to -last N-triggered Phase Absolute value in Table 8. 33. Press STBY on 1750 Download, and then Save. 23. Click on the calibrator. 20. Click on View Recorded, and then Events. 24. Starting from the CN Triggered Phase data. It...
Fluke 1750 Operators Manual
Page 3
Table of Contents Title Page Introduction...1 Contacting Fluke 2 Safety Information 3 Accessories ...4 Features...5 Applying the Front Panel Decal 7 Charging the PDA Battery 9 Installing the Software 9 Installing Power View on the PDA 9 Language Selection 10 ... 25 Navigating in Power View on the PDA 26 Power View Menus 26 Icons on the Menu Bar 27 Menu Tree...28 Home Screen...29 Downloading Data and Erasing Memory 31 Viewing Live Data 35 Scope Screen 35 Meter Screen 36 Phasor Screen 36 Harmonics Screen 37 Trend Screen 37 Viewing...
Table of Contents Title Page Introduction...1 Contacting Fluke 2 Safety Information 3 Accessories ...4 Features...5 Applying the Front Panel Decal 7 Charging the PDA Battery 9 Installing the Software 9 Installing Power View on the PDA 9 Language Selection 10 ... 25 Navigating in Power View on the PDA 26 Power View Menus 26 Icons on the Menu Bar 27 Menu Tree...28 Home Screen...29 Downloading Data and Erasing Memory 31 Viewing Live Data 35 Scope Screen 35 Meter Screen 36 Phasor Screen 36 Harmonics Screen 37 Trend Screen 37 Viewing...
Fluke 1750 Operators Manual
Page 9
Downloaded data goes onto the SD memory card plugged into the 1750, not directly to record. The range of probe is about 5 meters (16 feet) from Fluke. On the current inputs, the Recorder automatically identifies what type of the PDA with the wireless link is connected. If a phase ...channel is a comprehensive yet easy to use PC application, Power Analyze. 1750 Power Recorder Introduction The Fluke 1750 Power Recorder is wired incorrectly, you can view live readings and a phasor diagram on each phase that you are available from ...
Downloaded data goes onto the SD memory card plugged into the 1750, not directly to record. The range of probe is about 5 meters (16 feet) from Fluke. On the current inputs, the Recorder automatically identifies what type of the PDA with the wireless link is connected. If a phase ...channel is a comprehensive yet easy to use PC application, Power Analyze. 1750 Power Recorder Introduction The Fluke 1750 Power Recorder is wired incorrectly, you can view live readings and a phasor diagram on each phase that you are available from ...
Fluke 1750 Operators Manual
Page 10
...Power Analyze software on a PC after the event has been captured. Contacting Fluke To contact Fluke, call one of data from the Recorder to the PDA, and finally to conduct a power quality survey. 1750 Operators Manual • Automatic disturbance capture The Recorder uses an automatic, self... Singapore: +65-738-5655 • Anywhere in the software. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. To contact Technical Support: fpqsupport@fluke.com or 888-257-9897 2 You define thresholds for events after the fact without worrying about...
...Power Analyze software on a PC after the event has been captured. Contacting Fluke To contact Fluke, call one of data from the Recorder to the PDA, and finally to conduct a power quality survey. 1750 Operators Manual • Automatic disturbance capture The Recorder uses an automatic, self... Singapore: +65-738-5655 • Anywhere in the software. To view, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. To contact Technical Support: fpqsupport@fluke.com or 888-257-9897 2 You define thresholds for events after the fact without worrying about...
Fluke 1750 Operators Manual
Page 12
... lighting systems in fixed-equipment installations, such as an electricity meter or an overhead or underground utility service. Contact Fluke or a qualified recycler for downloading data Model 3140R, 400 A Clamps (4-not included with Basic version) AC power cord, 3 meters Personal Digital...Hazardous voltage. Table 2. Symbol W ~ J CAT IV Meaning Risk of this product as unsorted municipal waste. Protective conductor terminal. 1750 Operators Manual Table 1. Risk of international ac power plug adapters for the PDA charger International adapters for the Recorder power cord Part Number...
... lighting systems in fixed-equipment installations, such as an electricity meter or an overhead or underground utility service. Contact Fluke or a qualified recycler for downloading data Model 3140R, 400 A Clamps (4-not included with Basic version) AC power cord, 3 meters Personal Digital...Hazardous voltage. Table 2. Symbol W ~ J CAT IV Meaning Risk of this product as unsorted municipal waste. Protective conductor terminal. 1750 Operators Manual Table 1. Risk of international ac power plug adapters for the PDA charger International adapters for the Recorder power cord Part Number...
Fluke 1750 Operators Manual
Page 14
... not booted or locked Recording Recorder running on UPS M Ground Terminal Connecting the supplemental ground terminal and the line cord safety ground to a PC for downloading recorded data, and for transfer of large quantities of data. A USB SD card reader may also be used to connect the Recorder to different ground... transfer data to its speed and reliability. You can damage the Recorder. E SD status indicator Steady green SD card inserted Blinking Busy - This is used . 1750 Operators Manual Table 3.
... not booted or locked Recording Recorder running on UPS M Ground Terminal Connecting the supplemental ground terminal and the line cord safety ground to a PC for downloading recorded data, and for transfer of large quantities of data. A USB SD card reader may also be used to connect the Recorder to different ground... transfer data to its speed and reliability. You can damage the Recorder. E SD status indicator Steady green SD card inserted Blinking Busy - This is used . 1750 Operators Manual Table 3.
Fluke 1750 Operators Manual
Page 17
.... You should periodically check the Fluke website: www.fluke.com to install the ActiveSync software for Windows XP (or Mobile Device Center for download. Installing the Software This section describes how to reinstall this software in the future. 3. Follow the on-screen instructions to see if any 1750 firmware or application software updates are...
.... You should periodically check the Fluke website: www.fluke.com to install the ActiveSync software for Windows XP (or Mobile Device Center for download. Installing the Software This section describes how to reinstall this software in the future. 3. Follow the on-screen instructions to see if any 1750 firmware or application software updates are...
Fluke 1750 Operators Manual
Page 19
...session. Work Flow There are messages or notes you insert into the recorded data stream. Power Recorder Installing the Power Recorder at http://register.fluke.com or you can print the form and fax it allows you to get free software updates and helps us provide you need to ...when you may need to take a few minutes to change the language from the menu Settings>Language. 4. Edit the measurement description now or after downloading the measurement data and insert annotations and/or an optional START mark into the data stream during the recording session. • End of recording ...
...session. Work Flow There are messages or notes you insert into the recorded data stream. Power Recorder Installing the Power Recorder at http://register.fluke.com or you can print the form and fax it allows you to get free software updates and helps us provide you need to ...when you may need to take a few minutes to change the language from the menu Settings>Language. 4. Edit the measurement description now or after downloading the measurement data and insert annotations and/or an optional START mark into the data stream during the recording session. • End of recording ...
Fluke 1750 Operators Manual
Page 21
... steady-on. • Use the PHASOR screen on the current probe should be changed after data is recorded. The leads for example, 12000 V). 3. You can download data and ignore useless readings and events common at the beginning probe connecting activities. Make sure the nominal voltage, nominal line frequency, and power type...
... steady-on. • Use the PHASOR screen on the current probe should be changed after data is recorded. The leads for example, 12000 V). 3. You can download data and ignore useless readings and events common at the beginning probe connecting activities. Make sure the nominal voltage, nominal line frequency, and power type...
Fluke 1750 Operators Manual
Page 22
1750 Operators Manual descriptions such as an aid in Power View or Power Analyze...overwriting the oldest data (circular memory). You can erase internal memory for security reasons, or if you request a download action using the PDA or an attached PC. Power Type Diagrams The wiring illustrations included cover the standard power configurations...recommended and the fastest way to record, it using the Ethernet cable is not removed from the Recorder. Downloading to a PC running Fluke Power Analyze Software (included) using Power View software on the PDA or Power Analyze software on an ...
1750 Operators Manual descriptions such as an aid in Power View or Power Analyze...overwriting the oldest data (circular memory). You can erase internal memory for security reasons, or if you request a download action using the PDA or an attached PC. Power Type Diagrams The wiring illustrations included cover the standard power configurations...recommended and the fastest way to record, it using the Ethernet cable is not removed from the Recorder. Downloading to a PC running Fluke Power Analyze Software (included) using Power View software on the PDA or Power Analyze software on an ...
Fluke 1750 Operators Manual
Page 33
...power measurements wherever the Recorder is a "black box" with Power Analyze Software Fluke 1750 Power Recorder Direct Ethernet Connection Figure 14. You can analyze the recorded data using the Power Analyze software. There is recorded and downloaded to a PC, you are relieved of the burden of having to carry...no provision for a hardwired PDA interface to function as your control panel for the Recorder, since the Recorder itself is installed, or download data from a PC directly using an Ethernet cable or remotely over an IP network. The Power View software installed on the PDA,...
...power measurements wherever the Recorder is a "black box" with Power Analyze Software Fluke 1750 Power Recorder Direct Ethernet Connection Figure 14. You can analyze the recorded data using the Power Analyze software. There is recorded and downloaded to a PC, you are relieved of the burden of having to carry...no provision for a hardwired PDA interface to function as your control panel for the Recorder, since the Recorder itself is installed, or download data from a PC directly using an Ethernet cable or remotely over an IP network. The Power View software installed on the PDA,...
Fluke 1750 Operators Manual
Page 34
... • Nominal Power • Phase Swap • Volts/Current Ratio • Recorder Name/Password • Snapshot Period • Language 26 There are for download to the SD card inserted in Power View on the PDA The Menu Bar on your desktop computer using the Live menu. Power View Menus...that allows you can tap the appropriate icon to set recording period information. Menu Brings up a list of interest or the Live menu. 1750 Operators Manual Navigating in the Recorder and for viewing and analysis on the bottom of the Power View screen allows you to quickly and easily...
... • Nominal Power • Phase Swap • Volts/Current Ratio • Recorder Name/Password • Snapshot Period • Language 26 There are for download to the SD card inserted in Power View on the PDA The Menu Bar on your desktop computer using the Live menu. Power View Menus...that allows you can tap the appropriate icon to set recording period information. Menu Brings up a list of interest or the Live menu. 1750 Operators Manual Navigating in the Recorder and for viewing and analysis on the bottom of the Power View screen allows you to quickly and easily...
Fluke 1750 Operators Manual
Page 36
... be helpful in navigating through the Power View application. Power View Menu Tree azd15f.eps 28 Erase 1750 Memory Fluke Power View 1750 Power Recorders Found Connecting 1750 Power Recorder Not Found Live Scope Meter Phasor Harmonics Trend Home Menu Tools 1750 Setup Exit 1750 Download Write to SD SD Card Files Scope If Memory is full...
... be helpful in navigating through the Power View application. Power View Menu Tree azd15f.eps 28 Erase 1750 Memory Fluke Power View 1750 Power Recorders Found Connecting 1750 Power Recorder Not Found Live Scope Meter Phasor Harmonics Trend Home Menu Tools 1750 Setup Exit 1750 Download Write to SD SD Card Files Scope If Memory is full...
Fluke 1750 Operators Manual
Page 39
... If the password is incorrect the password text field is cleared and then you must move the card to the PDA. Tap 1750 Internal Memory in the Recorder. To download ALL, tap the Write to the SD card plugged into the Recorder's (not the PDA) SD card slot. You are START and... parameter changes that data, you can later copy the data to set up password protection for review using the Power Analyze software. Azd116.bmp The Download screen shows a three-phase rms V strip chart with triangular arrowheads at the bottom of the start point. Note A screen to your PC for a Recorder is...
... If the password is incorrect the password text field is cleared and then you must move the card to the PDA. Tap 1750 Internal Memory in the Recorder. To download ALL, tap the Write to the SD card plugged into the Recorder's (not the PDA) SD card slot. You are START and... parameter changes that data, you can later copy the data to set up password protection for review using the Power Analyze software. Azd116.bmp The Download screen shows a three-phase rms V strip chart with triangular arrowheads at the bottom of the start point. Note A screen to your PC for a Recorder is...
Fluke 1750 Operators Manual
Page 40
1750 Operators Manual Azd117.bmp If the SD storage card already contains data files, it may not have room for the new download. Power View alerts you to this condition and asks if you would like to delete files by selecting Tools>1750 SD Memory from the Data menu option. 32 Azd107s.bmp You can also access the SD card to erase the SD card before downloading.
1750 Operators Manual Azd117.bmp If the SD storage card already contains data files, it may not have room for the new download. Power View alerts you to this condition and asks if you would like to delete files by selecting Tools>1750 SD Memory from the Data menu option. 32 Azd107s.bmp You can also access the SD card to erase the SD card before downloading.
Fluke 1750 Operators Manual
Page 41
Power Recorder Downloading Data and Erasing Memory You can leave old data in the Recorder. It will appear. Azd108s.bmp When there is available under Menu, and tap ... to erase all power quality data stored in Recorder memory. Azd118.bmp You can also tap the Erase 1750 Memory from the Data menu option which is room on the card, a message confirming the download will be overwritten automatically when you can delete files as necessary, and when satisfied that there is...
Power Recorder Downloading Data and Erasing Memory You can leave old data in the Recorder. It will appear. Azd108s.bmp When there is available under Menu, and tap ... to erase all power quality data stored in Recorder memory. Azd118.bmp You can also tap the Erase 1750 Memory from the Data menu option which is room on the card, a message confirming the download will be overwritten automatically when you can delete files as necessary, and when satisfied that there is...
Fluke 1750 Operators Manual
Page 42
All of the functions (controller, PDA, and Power View) are duplicated in the 1750 Live mode. appears on the screen. Note You can also download data by connecting your PC directly to Erase All, the following popup caution "Are you sure?" Azd119.bmp 34 1750 Operators Manual Azd109s.bmp When you choose to the Recorder with an Ethernet cable and run Power Analyze in 1750 Live mode.
All of the functions (controller, PDA, and Power View) are duplicated in the 1750 Live mode. appears on the screen. Note You can also download data by connecting your PC directly to Erase All, the following popup caution "Are you sure?" Azd119.bmp 34 1750 Operators Manual Azd109s.bmp When you choose to the Recorder with an Ethernet cable and run Power Analyze in 1750 Live mode.
Fluke 1750 Operators Manual
Page 51
... Use this menu to add a ratio factor to the voltage or current input on the primary side at a substation or step-down transformer that you download from the Recorder. 43 The Recorder name is a potential transformer in metering current transformers. Power Recorder Setting Up the Recorder Azd133.bmp Setting the Volts...
... Use this menu to add a ratio factor to the voltage or current input on the primary side at a substation or step-down transformer that you download from the Recorder. 43 The Recorder name is a potential transformer in metering current transformers. Power Recorder Setting Up the Recorder Azd133.bmp Setting the Volts...
Fluke 1750 Operators Manual
Page 54
... Recorder. To open the file. To show a range of data. These markers only display in the 46 If the annotation is not in the Download dialog box. 1750 Operators Manual Azd137.bmp There are five types of a picture or audio file relevant to the data. If the file is associated with an... probe connections and instrument setup, to indicate that file will start and open an annotation: • In the Volts/Amps/Hz view, Events view, or Download dialog box, click on the view controls.
... Recorder. To open the file. To show a range of data. These markers only display in the 46 If the annotation is not in the Download dialog box. 1750 Operators Manual Azd137.bmp There are five types of a picture or audio file relevant to the data. If the file is associated with an... probe connections and instrument setup, to indicate that file will start and open an annotation: • In the Volts/Amps/Hz view, Events view, or Download dialog box, click on the view controls.