...has two kinds of 27 Not installing the NC REPO is equivalent of startup to swap any two input feed conductors. R12000/3 and A-B-C clockwise phase rotation The HP three phase UPS require A-B-C clockwise phase rotation for this condition, the electrician needs to make the correction if required. ...wiring. The NC REPO connector must be on call (or on site) at the time of a REPO signal being sent to the users guide detailed installation instructions. 8. Worldwide Power Requirements Page 19 of REPO (remote emergency power off) options, NO (normally open) and NC (normally closed)....
...has two kinds of 27 Not installing the NC REPO is equivalent of startup to swap any two input feed conductors. R12000/3 and A-B-C clockwise phase rotation The HP three phase UPS require A-B-C clockwise phase rotation for this condition, the electrician needs to make the correction if required. ...wiring. The NC REPO connector must be on call (or on site) at the time of a REPO signal being sent to the users guide detailed installation instructions. 8. Worldwide Power Requirements Page 19 of REPO (remote emergency power off) options, NO (normally open) and NC (normally closed)....
HP UPS R3000 User Guide
Page 32
... Manager software ensures maximum power reliability of computer systems through comprehensive control of HP Power Manager software, see the software user guide. The software user guide is available for analysis. • Manages independent UPS load segments to provide separate power control ...To download the latest version of UPSs. Power management 32 The easy-to-use browser interface enables novice users to sequence the startup of system components. HP Power Manager: • Does not require complex management systems, which simplifies deployment, configuration, and management ...
... Manager software ensures maximum power reliability of computer systems through comprehensive control of HP Power Manager software, see the software user guide. The software user guide is available for analysis. • Manages independent UPS load segments to provide separate power control ...To download the latest version of UPSs. Power management 32 The easy-to-use browser interface enables novice users to sequence the startup of system components. HP Power Manager: • Does not require complex management systems, which simplifies deployment, configuration, and management ...
HP UPS R3000 User Guide
Page 42
... location of a general fault condition, see the HP Power Manager user guide available for download from the HP website (http://www.hp.com/go /rackandpower). 2. For more information about the causes of individual LEDs, see the HP Power Manager user guide available for 24 hours. If the LED does ... 33) General alarm condition Action: 1. Yes Continuous On battery-Input voltage is out of airflow to charge for download from the HP website (http://www.hp.com/go /rackandpower). 2. b. Yes Continuous On-1 beep Yes every 5 seconds On- Troubleshooting 42 UPS is in Auto-Bypass...
... location of a general fault condition, see the HP Power Manager user guide available for download from the HP website (http://www.hp.com/go /rackandpower). 2. For more information about the causes of individual LEDs, see the HP Power Manager user guide available for 24 hours. If the LED does ... 33) General alarm condition Action: 1. Yes Continuous On battery-Input voltage is out of airflow to charge for download from the HP website (http://www.hp.com/go /rackandpower). 2. b. Yes Continuous On-1 beep Yes every 5 seconds On- Troubleshooting 42 UPS is in Auto-Bypass...
HP 3 Phase UPS User Guide
Page 1
HP 3 Phase UPS User Guide Abstract This document includes installation, configuration, and operation information for the person who installs and maintains power products. Part Number: 435256-004 January 2013 Edition: 4 This document is for the HP 3 Phase UPS. HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with hazardous energy levels.
HP 3 Phase UPS User Guide Abstract This document includes installation, configuration, and operation information for the person who installs and maintains power products. Part Number: 435256-004 January 2013 Edition: 4 This document is for the HP 3 Phase UPS. HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with hazardous energy levels.
HP 3 Phase UPS User Guide
Page 107
... or software • Operating system type and revision level HP contact information For United States and worldwide contact information, see the Contact HP website (http://www.hp.com/go/assistance). For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website (http://www.hp.com/go/ilo/docs). • Onboard Administrator SHOW ALL...
... or software • Operating system type and revision level HP contact information For United States and worldwide contact information, see the Contact HP website (http://www.hp.com/go/assistance). For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website (http://www.hp.com/go/ilo/docs). • Onboard Administrator SHOW ALL...
UPS R12000 XR Backplate Receptacle Kit Installation Instructions
Page 5
...document. For more information. 2. Replace the battery and electronics modules. Powering Up the UPS 1. Each module powers on the AC mains at www.hp.com/products/ups NOTE: Verify that the UPS is received. Power on in Bypass mode. NOTE: On initial utility startup, you start the ... Standby mode and continue to the HP website at the service panel by the Utility LED (1) slowly flashing green, after all electronics modules have synchronized. - The system begins charging the batteries but does not assume the load. - Refer to the UPS user guide for three seconds as part of ...
...document. For more information. 2. Replace the battery and electronics modules. Powering Up the UPS 1. Each module powers on the AC mains at www.hp.com/products/ups NOTE: Verify that the UPS is received. Power on in Bypass mode. NOTE: On initial utility startup, you start the ... Standby mode and continue to the HP website at the service panel by the Utility LED (1) slowly flashing green, after all electronics modules have synchronized. - The system begins charging the batteries but does not assume the load. - Refer to the UPS user guide for three seconds as part of ...
UPS R3000 XR Models User Guide
Page 2
... such products. Confidential computer software. Nothing herein should be liable for possession, use or copying. HP Uninterruptible Power System R3000 XR Models User Guide August 2002 (Third Edition) Part Number 192131-003 Valid license from HP required for technical or editorial errors or omissions contained herein. Hewlett-Packard Company shall not be construed... this document is subject to the U.S. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for HP products are licensed to change without notice.
... such products. Confidential computer software. Nothing herein should be liable for possession, use or copying. HP Uninterruptible Power System R3000 XR Models User Guide August 2002 (Third Edition) Part Number 192131-003 Valid license from HP required for technical or editorial errors or omissions contained herein. Hewlett-Packard Company shall not be construed... this document is subject to the U.S. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software Documentation, and Technical Data for HP products are licensed to change without notice.
UPS R3000 XR Models User Guide
Page 3
... the Batteries ...2-3 Placing the UPS in Operate Mode...2-3 Returning to Standby Mode...2-4 Initiating a Self-Test ...2-5 Audible Alarm...2-6 Silencing an Audible Alarm...2-7 Shutting Down the System ...2-7 HP Uninterruptible Power System R3000 XR Models User Guide iii
... the Batteries ...2-3 Placing the UPS in Operate Mode...2-3 Returning to Standby Mode...2-4 Initiating a Self-Test ...2-5 Audible Alarm...2-6 Silencing an Audible Alarm...2-7 Shutting Down the System ...2-7 HP Uninterruptible Power System R3000 XR Models User Guide iii
UPS R3000 XR Models User Guide
Page 4
... ...A-3 Canadian Notice (Avis Canadien)...A-4 Class A Equipment...A-4 Class B Equipment ...A-4 European Union Notice...A-4 Japanese Notice...A-5 China Taiwan Notice...A-5 Battery Replacement Notice ...A-6 Appendix B Electrostatic Discharge Grounding Methods ...B-1 iv HP Uninterruptible Power System R3000 XR Models User Guide
... ...A-3 Canadian Notice (Avis Canadien)...A-4 Class A Equipment...A-4 Class B Equipment ...A-4 European Union Notice...A-4 Japanese Notice...A-5 China Taiwan Notice...A-5 Battery Replacement Notice ...A-6 Appendix B Electrostatic Discharge Grounding Methods ...B-1 iv HP Uninterruptible Power System R3000 XR Models User Guide
UPS R3000 XR Models User Guide
Page 6
... personnel. Refer all servicing to qualified personnel. Intended Audience This guide is intended for injury exists if warnings are not observed. HP Uninterruptible Power System R3000 XR Models User Guide vii The potential for individuals requiring information about the use of ...a potential hazard. About This Guide This guide provides information for operation, configuration, battery maintenance...
... personnel. Refer all servicing to qualified personnel. Intended Audience This guide is intended for injury exists if warnings are not observed. HP Uninterruptible Power System R3000 XR Models User Guide vii The potential for individuals requiring information about the use of ...a potential hazard. About This Guide This guide provides information for operation, configuration, battery maintenance...
UPS R3000 XR Models User Guide
Page 7
...symbols may become unstable if more than one component is extended for uniform resource locators (URLs). WARNING: Text set off in this guide. NOTE: Text set off in this manner indicates that varies in system output, in command lines, and in command parameters in ... IMPORTANT: Text set off in this manner presents commentary, sidelights, or interesting points of published guides or variables. viii HP Uninterruptible Power System R3000 XR Models User Guide About This Guide Rack Stability WARNING: To prevent personal injury or damage to the equipment, verify that failure to...
...symbols may become unstable if more than one component is extended for uniform resource locators (URLs). WARNING: Text set off in this guide. NOTE: Text set off in this manner indicates that varies in system output, in command lines, and in command parameters in ... IMPORTANT: Text set off in this manner presents commentary, sidelights, or interesting points of published guides or variables. viii HP Uninterruptible Power System R3000 XR Models User Guide About This Guide Rack Stability WARNING: To prevent personal injury or damage to the equipment, verify that failure to...
UPS R3000 XR Models User Guide
Page 8
...User Guide ix About This Guide Related Documents For additional information on this guide, refer to www.hp.com. Have the following documents: • HP Uninterruptible Power System R3000 XR Models Installation Instructions • HP UPS R3000 XR Models Extended Runtime Module Installation Instructions • HP UPS XR Products Power Cord and Options Reference Guide... the information in this guide, further information and other help is available in this product as well as the latest drivers, firmware, and service packs, go to www.hp.com. HP Technical Support For telephone numbers...
...User Guide ix About This Guide Related Documents For additional information on this guide, refer to www.hp.com. Have the following documents: • HP Uninterruptible Power System R3000 XR Models Installation Instructions • HP UPS R3000 XR Models Extended Runtime Module Installation Instructions • HP UPS XR Products Power Cord and Options Reference Guide... the information in this guide, further information and other help is available in this product as well as the latest drivers, firmware, and service packs, go to www.hp.com. HP Technical Support For telephone numbers...
UPS R3000 XR Models User Guide
Page 9
About This Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: • In the United States, call 1-800-345-1518. • In Canada, call 1-800-263-5868. • Elsewhere, see the HP website for locations and telephone numbers. x HP Uninterruptible Power System R3000 XR Models User Guide Reader's Comments To comment on this guide, send an email to ServerDocumentation@hp.com.
About This Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: • In the United States, call 1-800-345-1518. • In Canada, call 1-800-263-5868. • Elsewhere, see the HP website for locations and telephone numbers. x HP Uninterruptible Power System R3000 XR Models User Guide Reader's Comments To comment on this guide, send an email to ServerDocumentation@hp.com.
UPS R3000 XR Models User Guide
Page 10
... the features of the UPS, including power management software, available hardware options, and warranties. Read this chapter to 3000 VA/2700 W • Load segment control HP Uninterruptible Power System R3000 XR Models User Guide 1-1 1 Overview This chapter contains a general overview of the UPS.
... the features of the UPS, including power management software, available hardware options, and warranties. Read this chapter to 3000 VA/2700 W • Load segment control HP Uninterruptible Power System R3000 XR Models User Guide 1-1 1 Overview This chapter contains a general overview of the UPS.
UPS R3000 XR Models User Guide
Page 11
...Port The UPS includes a communications port for data exchange with the UPS to connect the communications port to the host computer. HP UPS R3000 XR Models The UPS models include the following. CAUTION: Use only the specific cable supplied with the host computer.... with non-detachable CEE 7/7 SCHUKO plug International, high-voltage, rack-mountable UPS with non-detachable BS-546 plug 1-2 HP Uninterruptible Power System R3000 XR Models User Guide Overcurrent Protection Certain models feature overcurrent protection provided through resettable circuit protectors located on the UPS rear panel.
...Port The UPS includes a communications port for data exchange with the UPS to connect the communications port to the host computer. HP UPS R3000 XR Models The UPS models include the following. CAUTION: Use only the specific cable supplied with the host computer.... with non-detachable CEE 7/7 SCHUKO plug International, high-voltage, rack-mountable UPS with non-detachable BS-546 plug 1-2 HP Uninterruptible Power System R3000 XR Models User Guide Overcurrent Protection Certain models feature overcurrent protection provided through resettable circuit protectors located on the UPS rear panel.
UPS R3000 XR Models User Guide
Page 12
Overview 1 23 Figure 1-1: Front panel configuration 1 Battery compartment 2 Control buttons 3 LED display For detailed information on using the control buttons and LED indicators, refer to the section, "Front Panel Controls and LED Indicators," in Figure 1-1. HP Uninterruptible Power System R3000 XR Models User Guide 1-3 Front Panel The front panel of the UPS is shown in Chapter 2.
Overview 1 23 Figure 1-1: Front panel configuration 1 Battery compartment 2 Control buttons 3 LED display For detailed information on using the control buttons and LED indicators, refer to the section, "Front Panel Controls and LED Indicators," in Figure 1-1. HP Uninterruptible Power System R3000 XR Models User Guide 1-3 Front Panel The front panel of the UPS is shown in Chapter 2.
UPS R3000 XR Models User Guide
Page 13
Overview Rear Panels The rear panels of the UPS models are shown in Figure 1-2 through Figure 1-7. 12 3 456 10 9 8 7 Figure 1-2: Rear panel of R3000 XR-NA and R3000 XR-JPN 1 REPO port 2 ERM connector 3 Communications port/option slot 4 Load segment 1 (two NEMA 5-15 receptacles) 5 Load segment 2 (two NEMA 5-15 receptacles) 6 Load segment 3 (two NEMA 5-15 receptacles) 7 Load segment circuit protectors 8 PDU output (L5-30) receptacle (load segment 1) 9 Cord retention clip attachment locations 10 Ground bonding screw 1-4 HP Uninterruptible Power System R3000 XR Models User Guide
Overview Rear Panels The rear panels of the UPS models are shown in Figure 1-2 through Figure 1-7. 12 3 456 10 9 8 7 Figure 1-2: Rear panel of R3000 XR-NA and R3000 XR-JPN 1 REPO port 2 ERM connector 3 Communications port/option slot 4 Load segment 1 (two NEMA 5-15 receptacles) 5 Load segment 2 (two NEMA 5-15 receptacles) 6 Load segment 3 (two NEMA 5-15 receptacles) 7 Load segment circuit protectors 8 PDU output (L5-30) receptacle (load segment 1) 9 Cord retention clip attachment locations 10 Ground bonding screw 1-4 HP Uninterruptible Power System R3000 XR Models User Guide
UPS R3000 XR Models User Guide
Page 14
12 3 456 10 9 8 7 Figure 1-3: Rear panel of R3000h XR-NA and R3000h XR-JPN 1 REPO port 2 ERM connector 3 Communications port/option slot 4 Load segment 1 (three IEC-320-C13 receptacles) 5 Load segment 2 (three IEC-320-C13 receptacles) 6 Load segment 3 (three IEC-320-C13 receptacles) 7 PDU output (L6-20) receptacle (load segment 1) 8 Cord retention clip attachment locations 9 Ground bonding screw 10 Power cord with L6-20 plug Overview HP Uninterruptible Power System R3000 XR Models User Guide 1-5
12 3 456 10 9 8 7 Figure 1-3: Rear panel of R3000h XR-NA and R3000h XR-JPN 1 REPO port 2 ERM connector 3 Communications port/option slot 4 Load segment 1 (three IEC-320-C13 receptacles) 5 Load segment 2 (three IEC-320-C13 receptacles) 6 Load segment 3 (three IEC-320-C13 receptacles) 7 PDU output (L6-20) receptacle (load segment 1) 8 Cord retention clip attachment locations 9 Ground bonding screw 10 Power cord with L6-20 plug Overview HP Uninterruptible Power System R3000 XR Models User Guide 1-5
UPS R3000 XR Models User Guide
Page 15
... 3.5 mA. If the total earth (ground) conductor leakage current exceeds 3.5 mA, use the UPS R3000i XR-EURO, R3000i XR-SCHUKO, or R3000i XR-SA model. 1-6 HP Uninterruptible Power System R3000 XR Models User Guide
... 3.5 mA. If the total earth (ground) conductor leakage current exceeds 3.5 mA, use the UPS R3000i XR-EURO, R3000i XR-SCHUKO, or R3000i XR-SA model. 1-6 HP Uninterruptible Power System R3000 XR Models User Guide
UPS R3000 XR Models User Guide
Page 16
12 3 456 7 11 10 9 8 Figure 1-5: Rear panel of R3000i XR-EURO 1 REPO port 2 ERM connector 3 Communications port/option slot 4 Load segment 1 (three IEC-320-C13 receptacles) 5 Load segment 2 (three IEC-320-C13 receptacles) 6 Load segment 3 (three IEC-320-C13 receptacles) 7 Load segment circuit protectors 8 PDU output (IEC-320-C20) receptacle (load segment 1) 9 Cord retention clip attachment locations 10 Ground bonding screw 11 Power cord with IEC-309 plug Overview HP Uninterruptible Power System R3000 XR Models User Guide 1-7
12 3 456 7 11 10 9 8 Figure 1-5: Rear panel of R3000i XR-EURO 1 REPO port 2 ERM connector 3 Communications port/option slot 4 Load segment 1 (three IEC-320-C13 receptacles) 5 Load segment 2 (three IEC-320-C13 receptacles) 6 Load segment 3 (three IEC-320-C13 receptacles) 7 Load segment circuit protectors 8 PDU output (IEC-320-C20) receptacle (load segment 1) 9 Cord retention clip attachment locations 10 Ground bonding screw 11 Power cord with IEC-309 plug Overview HP Uninterruptible Power System R3000 XR Models User Guide 1-7