Owners Manual
Page 1
BEFORE using this product, read this manual and save for future reference. Invacare® Reliant™ 450 RHL450-1 Invacare Reliant 450 RPL450-1 Invacare Reliant 600 RPL600-1 Manual/Electric Portable Patient Lift User Manual EN This manual MUST be given to the user of the product.
BEFORE using this product, read this manual and save for future reference. Invacare® Reliant™ 450 RHL450-1 Invacare Reliant 450 RPL450-1 Invacare Reliant 600 RPL600-1 Manual/Electric Portable Patient Lift User Manual EN This manual MUST be given to the user of the product.
Owners Manual
Page 2
Trademarks are owned by ™ and ®. All trademarks are identified by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. Manual/Electric Portable Patient Lift 2 Part No. 1078987 Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. All rights reserved. © 2011 Invacare Corporation.
Trademarks are owned by ™ and ®. All trademarks are identified by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. Manual/Electric Portable Patient Lift 2 Part No. 1078987 Republication, duplication or modification in whole or in part is prohibited without prior written permission from Invacare. All rights reserved. © 2011 Invacare Corporation.
Owners Manual
Page 3
... 7 General Guidelines 7 6 Operating Information 7 General 7 Pinch Points and Positioning 8 Assembling the Lift 8 Operating the Lift 8 Using the Sling 9 Lifting the Patient 9 Transferring the Patient 10 Performing Maintenance 10 Electrical and Grounding 11 7 Disposal 11 Radio Frequency Interference 11 3 PRODUCT LABELING 12 4 TECHNICAL DATA 13 Patient Lift 13 Full Body, Divided Leg and Toileting Slings 14 Reliant Scale...
... 7 General Guidelines 7 6 Operating Information 7 General 7 Pinch Points and Positioning 8 Assembling the Lift 8 Operating the Lift 8 Using the Sling 9 Lifting the Patient 9 Transferring the Patient 10 Performing Maintenance 10 Electrical and Grounding 11 7 Disposal 11 Radio Frequency Interference 11 3 PRODUCT LABELING 12 4 TECHNICAL DATA 13 Patient Lift 13 Full Body, Divided Leg and Toileting Slings 14 Reliant Scale...
Owners Manual
Page 4
... ACCESSORIES 50 Reliant Scale RLS6 50 Removing the Swivel Bar 50 Installing the Reliant Scale 52 Operating the Scale 54 Keypad Functions 54 Weighing the Patient 55 Replacing the Battery 56 Calibrating the Reliant Scale 57 Troubleshooting 58 Display Codes 58 Manual/Electric Portable Patient Lift 4 Part No. 1078987
... ACCESSORIES 50 Reliant Scale RLS6 50 Removing the Swivel Bar 50 Installing the Reliant Scale 52 Operating the Scale 54 Keypad Functions 54 Weighing the Patient 55 Replacing the Battery 56 Calibrating the Reliant Scale 57 Troubleshooting 58 Display Codes 58 Manual/Electric Portable Patient Lift 4 Part No. 1078987
Owners Manual
Page 5
..., see instructions for use . CAUTION Caution indicates a potentially hazardous situation which could result in death or serious injury. ƽ ! Part No. 1078987 5 Manual/Electric Portable Patient Lift
..., see instructions for use . CAUTION Caution indicates a potentially hazardous situation which could result in death or serious injury. ƽ ! Part No. 1078987 5 Manual/Electric Portable Patient Lift
Owners Manual
Page 6
... LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU. Manual/Electric Portable Patient Lift 6 Part No. 1078987 1 GENERAL 1.2 Limited Warranty PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH ...THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED, PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE, PRODUCTS MODIFIED WITHOUT INVACARE'S EXPRESS WRITTEN CONSENT (INCLUDING, BUT NOT LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS; If within 30 days...
... LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU. Manual/Electric Portable Patient Lift 6 Part No. 1078987 1 GENERAL 1.2 Limited Warranty PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH ...THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED, PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE, PRODUCTS MODIFIED WITHOUT INVACARE'S EXPRESS WRITTEN CONSENT (INCLUDING, BUT NOT LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR ATTACHMENTS; If within 30 days...
Owners Manual
Page 7
... first completely reading and understanding these instructions and any available optional equipment without approval of the patient's physician, nurse or medical assistant. Invacare slings and patient lift accessories are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by other manufacturers are not to...
... first completely reading and understanding these instructions and any available optional equipment without approval of the patient's physician, nurse or medical assistant. Invacare slings and patient lift accessories are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by other manufacturers are not to...
Owners Manual
Page 8
... patient. Manual/Electric Portable Patient Lift 8 Part No. 1078987 Injury could be aware of the position of one assistant. DO NOT exceed maximum weight limitation of Lift Assembling the Lift ƽ WARNING DO NOT overtighten mounting hardware. Operating the Lift ƽ WARNING Although Invacare... recommends that two assistants be used for each individual case. The weight limitation for the RHL450-1 and RPL450-1 is based on...
... patient. Manual/Electric Portable Patient Lift 8 Part No. 1078987 Injury could be aware of the position of one assistant. DO NOT exceed maximum weight limitation of Lift Assembling the Lift ƽ WARNING DO NOT overtighten mounting hardware. Operating the Lift ƽ WARNING Although Invacare... recommends that two assistants be used for each individual case. The weight limitation for the RHL450-1 and RPL450-1 is based on...
Owners Manual
Page 9
... ensure that it easy to check the sling attachments each laundering (in injury. Make sure that there is sufficient head support when lifting a patient. Doing so could result in accordance with Invacare Patient Lifts. Invacare does recommend that the rear casters be made specifically for wear, tears, and loose stitching. Be sure to connect both sides...
... ensure that it easy to check the sling attachments each laundering (in injury. Make sure that there is sufficient head support when lifting a patient. Doing so could result in accordance with Invacare Patient Lifts. Invacare does recommend that the rear casters be made specifically for wear, tears, and loose stitching. Be sure to connect both sides...
Owners Manual
Page 10
... Maintenance ƽ WARNING Maintenance MUST be made. After the first year of use of patient lifts and accessories is necessary to check for transport. If the metal is removed from the bed or chair. Consult your dealer or write Invacare for wear. This will VOID the warranty and might result in a locked position...
... Maintenance ƽ WARNING Maintenance MUST be made. After the first year of use of patient lifts and accessories is necessary to check for transport. If the metal is removed from the bed or chair. Consult your dealer or write Invacare for wear. This will VOID the warranty and might result in a locked position...
Owners Manual
Page 11
... and obligation of batteries in the area around such equipment. In addition, Invacare has placed RED/ORANGE warning tags on some equipment. Part No. 1078987 11 Manual/Electric Portable Patient Lift DO NOT remove these tags. DO NOT dispose of the customer to the... and Grounding Ꮨ WARNING GROUNDING INSTRUCTIONS DO NOT, under any plug used with or for Invacare products. Some devices are not appropriate according to installing, servicing or operating your patient lift. Where a two-prong wall receptacle is encountered, it is in accordance with three-prong (...
... and obligation of batteries in the area around such equipment. In addition, Invacare has placed RED/ORANGE warning tags on some equipment. Part No. 1078987 11 Manual/Electric Portable Patient Lift DO NOT remove these tags. DO NOT dispose of the customer to the... and Grounding Ꮨ WARNING GROUNDING INSTRUCTIONS DO NOT, under any plug used with or for Invacare products. Some devices are not appropriate according to installing, servicing or operating your patient lift. Where a two-prong wall receptacle is encountered, it is in accordance with three-prong (...
Owners Manual
Page 12
... lock the casters of the Patient Lift when lifting an individual. Casters MUST be left unlocked to allow Patient Lift to tip over uneven surfaces that may cause the Patient Lift to stabilize during lifting procedures. Customer Service 1-800-333-6900 1070965 Rev B Manual/Electric Portable Patient Lift Electric Lift shown. USE ONLY Invacare slings and lift accessories. WEIGHT LIMITATION 600 lbs...
... lock the casters of the Patient Lift when lifting an individual. Casters MUST be left unlocked to allow Patient Lift to tip over uneven surfaces that may cause the Patient Lift to stabilize during lifting procedures. Customer Service 1-800-333-6900 1070965 Rev B Manual/Electric Portable Patient Lift Electric Lift shown. USE ONLY Invacare slings and lift accessories. WEIGHT LIMITATION 600 lbs...
Owners Manual
Page 13
... Carton: Battery: Charger Input: Charger Output/Charging Time: Accessories: Audio Low Battery Alarm: Motor Safety Devices: Approx. ELECTRIC LOW PROFILE RPL450-1 LOW PROFILE RPL600-1 74 inches 68 inches 24 inches 28 inches 41.0 inches 26.5 inches 4.5 inches 4.5 inches 48.0 inches 3.0/5.0... per Charge (Varies depending upon load and stroke): Warranty Pump/ Electronics: Part No. 1078987 4 TECHNICAL DATA 450 LB. 4 Technical Data 4.1 Patient Lift Height at Sling Hook-up - HYDRAULIC LOW PROFILE RHL450-1 71 inches 25 inches 4.5 inches 3.0/5.0 inches 3 Styles 112 lbs 93 lbs N/A N/A...
... Carton: Battery: Charger Input: Charger Output/Charging Time: Accessories: Audio Low Battery Alarm: Motor Safety Devices: Approx. ELECTRIC LOW PROFILE RPL450-1 LOW PROFILE RPL600-1 74 inches 68 inches 24 inches 28 inches 41.0 inches 26.5 inches 4.5 inches 4.5 inches 48.0 inches 3.0/5.0... per Charge (Varies depending upon load and stroke): Warranty Pump/ Electronics: Part No. 1078987 4 TECHNICAL DATA 450 LB. 4 Technical Data 4.1 Patient Lift Height at Sling Hook-up - HYDRAULIC LOW PROFILE RHL450-1 71 inches 25 inches 4.5 inches 3.0/5.0 inches 3 Styles 112 lbs 93 lbs N/A N/A...
Owners Manual
Page 14
... Two (2) minutes 5-3/4 L X 3-5/8 W X 4 H .55 Lbs Nine (9) Volt Alkaline battery (included) Approximately 1500 readings 50° To 104°F (10° To 40°C) Manual/Electric Portable Patient Lift 14 Part No. 1078987
... Two (2) minutes 5-3/4 L X 3-5/8 W X 4 H .55 Lbs Nine (9) Volt Alkaline battery (included) Approximately 1500 readings 50° To 104°F (10° To 40°C) Manual/Electric Portable Patient Lift 14 Part No. 1078987
Owners Manual
Page 15
... that secures the boom to the mast in Assembling the Manual/Hydraulic Pump to the Boom on page 18. Unpacking the Patient Lift 1. 5 Assembly 5 ASSEMBLY 5.1 Assembling the Patient Lift ƽ WARNING Use only Invacare parts in the assembly of all parts for safe functional operation. The base legs, the mast, boom, pump assembly and the... Boom on page 17 or Assembling the Electric Actuator to specifications that assure correct alignment of this time Part No. 1078987 15 Manual/Electric Portable Patient Lift
... that secures the boom to the mast in Assembling the Manual/Hydraulic Pump to the Boom on page 18. Unpacking the Patient Lift 1. 5 Assembly 5 ASSEMBLY 5.1 Assembling the Patient Lift ƽ WARNING Use only Invacare parts in the assembly of all parts for safe functional operation. The base legs, the mast, boom, pump assembly and the... Boom on page 17 or Assembling the Electric Actuator to specifications that assure correct alignment of this time Part No. 1078987 15 Manual/Electric Portable Patient Lift
Owners Manual
Page 16
... mast may be properly secured to LOCK. Locking Lever Mast Base Washers Shoulder Bolt Nut Mast U-shaped Cutout Shoulder Bolt Washers Nut Manual/Electric Portable Patient Lift 16 Part No. 1078987 Step here to the base assembly. Step here to the Base 1. If locking-type casters are on the...
... mast may be properly secured to LOCK. Locking Lever Mast Base Washers Shoulder Bolt Nut Mast U-shaped Cutout Shoulder Bolt Washers Nut Manual/Electric Portable Patient Lift 16 Part No. 1078987 Step here to the base assembly. Step here to the Base 1. If locking-type casters are on the...
Owners Manual
Page 17
Remove the shoulder bolt, washer and nut from the patient lift carton. 5 ASSEMBLY Mounting Bracket The bottom of the hydraulic pump ...61545; Pinch Guard Turn 90° Be sure that secures the boom and mast together. 4. Lift-up on the boom and place it lines-up with those of the hydraulic pump assembly will pivot easily if...assembly is completely through the holes of the hydraulic pump. 7. Part No. 1078987 17 Manual/Electric Portable Patient Lift Align the holes of the boom assembly mounting bracket with the mounting bracket holes in the boom assembly. ...
Remove the shoulder bolt, washer and nut from the patient lift carton. 5 ASSEMBLY Mounting Bracket The bottom of the hydraulic pump ...61545; Pinch Guard Turn 90° Be sure that secures the boom and mast together. 4. Lift-up on the boom and place it lines-up with those of the hydraulic pump assembly will pivot easily if...assembly is completely through the holes of the hydraulic pump. 7. Part No. 1078987 17 Manual/Electric Portable Patient Lift Align the holes of the boom assembly mounting bracket with the mounting bracket holes in the boom assembly. ...
Owners Manual
Page 18
.... 5. Secure with the mounting holes in the electrical connectors from the electric actuator to the mast mounting bracket. 3. Manual/Electric Portable Patient Lift 18 Part No. 1078987 Cut the plastic-wrap that the bolt is secured to the mast mounting bracket. Align the holes of the ...6. Place the pinch guard over the shaft extension of the actuator and insert the bolt. Remove the shoulder bolt, washer and nut from the patient lift carton. Lift-up with nut. Pinch Guard Turn 90° Be sure that secures the boom and mast together. 4. 5 ASSEMBLY ...
.... 5. Secure with the mounting holes in the electrical connectors from the electric actuator to the mast mounting bracket. 3. Manual/Electric Portable Patient Lift 18 Part No. 1078987 Cut the plastic-wrap that the bolt is secured to the mast mounting bracket. Align the holes of the ...6. Place the pinch guard over the shaft extension of the actuator and insert the bolt. Remove the shoulder bolt, washer and nut from the patient lift carton. Lift-up with nut. Pinch Guard Turn 90° Be sure that secures the boom and mast together. 4. 5 ASSEMBLY ...
Owners Manual
Page 19
Remove the shifter handle from the packaging carton. 2. Turn the shifter handle clockwise and securely tighten into the base. 5.2 Installing the Shifter Handle 1. Shifter Handle 5 ASSEMBLY Threads Opening in the base. 3. Line-up the shifter handle threads with threaded opening in Base Part No. 1078987 19 Manual/Electric Portable Patient Lift
Remove the shifter handle from the packaging carton. 2. Turn the shifter handle clockwise and securely tighten into the base. 5.2 Installing the Shifter Handle 1. Shifter Handle 5 ASSEMBLY Threads Opening in the base. 3. Line-up the shifter handle threads with threaded opening in Base Part No. 1078987 19 Manual/Electric Portable Patient Lift
Owners Manual
Page 20
...The shifter handle is used for all lifting preparation, transferring from and transferring to the maximum open position and lock the shifter handle immediately. 6 OPERATION 6 Operation 6.1 Operating the Patient Lift Although Invacare recommends that two assistants be in the... maximum open position and the shifter handle locked in this Owner's Manual, observe a trained team of the patient's physician, nurse or medical assistant.
...The shifter handle is used for all lifting preparation, transferring from and transferring to the maximum open position and lock the shifter handle immediately. 6 OPERATION 6 Operation 6.1 Operating the Patient Lift Although Invacare recommends that two assistants be in the... maximum open position and the shifter handle locked in this Owner's Manual, observe a trained team of the patient's physician, nurse or medical assistant.