Service Manual
Page 23
Test 6 Heater switch test - Drying time takes longer. Is resistance between Heater terminal and below 18 ~ 22Ω? 2. NO YES • Replace TH3 (HI-Limit Thermostat). Electric Type Caution Before ... RUN condition. • Check Motor and replace it. Check Motor. YES Check if the value of Power cord with earth line.) Trouble Symptom While operating, Heating will not work. NO • Replace Heater. Is resistance between terminal TH3 (HI-Limit Thermostat). TH3 TH2 1. NO YES • Replace TH2 (Safety Thermostat). Check...
Test 6 Heater switch test - Drying time takes longer. Is resistance between Heater terminal and below 18 ~ 22Ω? 2. NO YES • Replace TH3 (HI-Limit Thermostat). Electric Type Caution Before ... RUN condition. • Check Motor and replace it. Check Motor. YES Check if the value of Power cord with earth line.) Trouble Symptom While operating, Heating will not work. NO • Replace Heater. Is resistance between terminal TH3 (HI-Limit Thermostat). TH3 TH2 1. NO YES • Replace TH2 (Safety Thermostat). Check...
Service Manual
Page 24
Drying time takes longer. Trouble Symptom While operating, Heating will not work. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect ...
Drying time takes longer. Trouble Symptom While operating, Heating will not work. YES NO • Check thermostat Hi limit Safety Igniter operates? (after 1 min, Igniter becomes reddish) YES NO • Check Igniter & Frame detect ...