MEGA ARM / MEGA ARM TOWER Manual
Page 1
Use (2) LiftMaster 12 Vdc 7AH (Part # MBAT). The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com MADCBB, MATDCBB, MASDCBB, & MASTDCBB HEAVY-DUTY DC BARRIER GATE OPERATOR OWNER'S MANUAL RREINCACELDUIIVDOEEDR MEGA ARM TOWER & MEGA SPRINT TOWER MEGA ARM & MEGA SPRINT IMPORTANT: Read and understand Warranty Page first. Batteries (included) MUST be connected for proper operation of operator.
Use (2) LiftMaster 12 Vdc 7AH (Part # MBAT). The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com MADCBB, MATDCBB, MASDCBB, & MASTDCBB HEAVY-DUTY DC BARRIER GATE OPERATOR OWNER'S MANUAL RREINCACELDUIIVDOEEDR MEGA ARM TOWER & MEGA SPRINT TOWER MEGA ARM & MEGA SPRINT IMPORTANT: Read and understand Warranty Page first. Batteries (included) MUST be connected for proper operation of operator.
MEGA ARM / MEGA ARM TOWER Manual
Page 5
... This model is sensed at close travel if tail-gating is intended for use in vehicular gate applications. • High torque 24 volt Permanent Magnet DC motor • On 120 Vac installations, unswitched duplex outlet gives convenient supply for accessories • Capable of the art MOSFET motor drive technology, NO contactors...
... This model is sensed at close travel if tail-gating is intended for use in vehicular gate applications. • High torque 24 volt Permanent Magnet DC motor • On 120 Vac installations, unswitched duplex outlet gives convenient supply for accessories • Capable of the art MOSFET motor drive technology, NO contactors...
MEGA ARM / MEGA ARM TOWER Manual
Page 10
... with slip clutch option) and fires relay when a tail-gate is not already in pairs using LiftMaster MBAT or 29-NP712 batteries. EXAMPLE: Vehicle detector, radio receiver. K1 D11 U19 Aux Relay J1 C NC NO DC 1 PWR D12 R13 J4 D14 BAT- 1 F3 MOV ACC+ ACC- Relay will fire when ...without installing the batteries. ALWAYS CONNECT AC POWER BEFORE INSTALLING BATTERIES. 1 Connect AC power BEFORE installing batteries. 2 Install two new, fully charged 12 volt DC batteries on the J4 Terminal Block S1 DIP Switch Block S1-6 S1-8 1 J2 AUX LIMITS D8 S1 12 R1 1 D1Ø S2 12 BATTERY ...
... with slip clutch option) and fires relay when a tail-gate is not already in pairs using LiftMaster MBAT or 29-NP712 batteries. EXAMPLE: Vehicle detector, radio receiver. K1 D11 U19 Aux Relay J1 C NC NO DC 1 PWR D12 R13 J4 D14 BAT- 1 F3 MOV ACC+ ACC- Relay will fire when ...without installing the batteries. ALWAYS CONNECT AC POWER BEFORE INSTALLING BATTERIES. 1 Connect AC power BEFORE installing batteries. 2 Install two new, fully charged 12 volt DC batteries on the J4 Terminal Block S1 DIP Switch Block S1-6 S1-8 1 J2 AUX LIMITS D8 S1 12 R1 1 D1Ø S2 12 BATTERY ...
MEGA ARM / MEGA ARM TOWER Manual
Page 12
... AGAINST FIRE DX1 REPLACE ONLY WITH THE SAME TYPE AND RATING OF FUSE MOV U6 MOTOR TR PWR ACC+ ACC- FIGURE 2 Aux Relay C NC NO DC 1 P1-P4 TR Q6 Q5 Q4 D28 B2 Security Mode Terminals Jumper Security Mode Terminals Jumper PROGRAMMING THE REMOTE TO THE RECEIVER 1 Pry open /push... U16 D27 U7 HBEAT BAT LO AC POWER C6 DX3 U1Ø P2 to J5 Terminal 10 R56 DX2 R51 R55 D2Ø D26 1A DC ACC+ ACC- F3 MOV 1 10 TYPE AND RATING OF1FUSE 2 3 MOT4OR D25 - Repeat Steps 2 and 3 for changing the code setting or replacing the battery. THERE ARE...
... AGAINST FIRE DX1 REPLACE ONLY WITH THE SAME TYPE AND RATING OF FUSE MOV U6 MOTOR TR PWR ACC+ ACC- FIGURE 2 Aux Relay C NC NO DC 1 P1-P4 TR Q6 Q5 Q4 D28 B2 Security Mode Terminals Jumper Security Mode Terminals Jumper PROGRAMMING THE REMOTE TO THE RECEIVER 1 Pry open /push... U16 D27 U7 HBEAT BAT LO AC POWER C6 DX3 U1Ø P2 to J5 Terminal 10 R56 DX2 R51 R55 D2Ø D26 1A DC ACC+ ACC- F3 MOV 1 10 TYPE AND RATING OF1FUSE 2 3 MOT4OR D25 - Repeat Steps 2 and 3 for changing the code setting or replacing the battery. THERE ARE...
MEGA ARM / MEGA ARM TOWER Manual
Page 18
... the K1 relay of the trap operator to 00100010 where 1 is up and 0 is open . • When the second gate is down . Reconnect the DC power by replacing the neutral (Black) wire to the operator. 3. The second gate should open , activate the close . Press the connector into the J1 connector... pins. TRAP SET UP Interlock C TES S1-6 OFF S1-8 ON OPEN Trap MA C NC NO DC K1 S1-6 OFF S1-8 OFF MA Opener Common SET THE DIP SWITCHES AT THE SECOND OPERATOR 1. Reconnect the AC Power to the battery terminal. 2. See...
... the K1 relay of the trap operator to 00100010 where 1 is up and 0 is open . • When the second gate is down . Reconnect the DC power by replacing the neutral (Black) wire to the operator. 3. The second gate should open , activate the close . Press the connector into the J1 connector... pins. TRAP SET UP Interlock C TES S1-6 OFF S1-8 ON OPEN Trap MA C NC NO DC K1 S1-6 OFF S1-8 OFF MA Opener Common SET THE DIP SWITCHES AT THE SECOND OPERATOR 1. Reconnect the AC Power to the battery terminal. 2. See...
MEGA ARM / MEGA ARM TOWER Manual
Page 20
... D2 U3 R5 U2 R4 C4 CPU R19 JP2 F2 R38 R37 R51 D2Ø DX2 R55 R3 Q1 D9 R2Ø + C5 F1 1A DC C8 C2Ø + R15 D1 + F4 R2 R11 B1 HBEAT BAT LO AC POWER K1 D11 D12 D14 F3 WARNING FOR R62 CONTINUOUS PROTECTION AGAINST... the "Close" position for 24 Vdc battery input power. (UL listed fuse only.) 20 D11: Heart beat. MOV MOTOR Aux Relay TR J1 C NC NO DC 1 1 B2 + PWR K1 Relay Terminals (Optional) ACC+ ACC-
... D2 U3 R5 U2 R4 C4 CPU R19 JP2 F2 R38 R37 R51 D2Ø DX2 R55 R3 Q1 D9 R2Ø + C5 F1 1A DC C8 C2Ø + R15 D1 + F4 R2 R11 B1 HBEAT BAT LO AC POWER K1 D11 D12 D14 F3 WARNING FOR R62 CONTINUOUS PROTECTION AGAINST... the "Close" position for 24 Vdc battery input power. (UL listed fuse only.) 20 D11: Heart beat. MOV MOTOR Aux Relay TR J1 C NC NO DC 1 1 B2 + PWR K1 Relay Terminals (Optional) ACC+ ACC-
MEGA ARM / MEGA ARM TOWER Manual
Page 22
... 1 18 17 8 7 9 19 15 3 14 4 6 NOTE: Mega Arm Tower not shown PART NUMBERS AND DESCRIPTIONS ITEM PART NUMBER DESCRIPTION 1 MA001 Controller 2 MA002 Removable Connector 3 MA003 DC Motor - 24 Vdc 4 MBAT 12 Vdc 7AH Battery 2 required 5 MA005 Gear Reducer 60:1 6 MA006 Aluminum Chassis 7 MA007 Drive Belt 8 MA008 Reducer Pulley 9 MA009 Motor Pulley...
... 1 18 17 8 7 9 19 15 3 14 4 6 NOTE: Mega Arm Tower not shown PART NUMBERS AND DESCRIPTIONS ITEM PART NUMBER DESCRIPTION 1 MA001 Controller 2 MA002 Removable Connector 3 MA003 DC Motor - 24 Vdc 4 MBAT 12 Vdc 7AH Battery 2 required 5 MA005 Gear Reducer 60:1 6 MA006 Aluminum Chassis 7 MA007 Drive Belt 8 MA008 Reducer Pulley 9 MA009 Motor Pulley...