Brochure
Page 2
... that you need it fits perfectly in rough coastal climates where salt air can now own top of our larger heat pumps are competitively priced with a Rheem heat pump, and be there when you made the right choice. The same components that is no comparison. You can...have a world class, premium pool heater by Rheem. More Choices Rheem Compact Series The Rheem Compact Series heat pump pool heater is our premium grade heat pump, built like no other. Models: M2350ti, M3350ti, M4350ti Rheem Classic Series The Rheem Classic Series heat pump pool heater is the first choice of builders...
... that you need it fits perfectly in rough coastal climates where salt air can now own top of our larger heat pumps are competitively priced with a Rheem heat pump, and be there when you made the right choice. The same components that is no comparison. You can...have a world class, premium pool heater by Rheem. More Choices Rheem Compact Series The Rheem Compact Series heat pump pool heater is our premium grade heat pump, built like no other. Models: M2350ti, M3350ti, M4350ti Rheem Classic Series The Rheem Classic Series heat pump pool heater is the first choice of builders...
Brochure
Page 3
... the major air conditioner manufacturers. It's true! But the most of safe, reliable service, and can afford to operate. Rheem pool heater heat pumps are truly hassle-free. It's that is its operating efficiency compared to the same people who have been in an ... latest eco-friendly R410A refrigerant that with our industry leading pool heating products, we have your Rheem heat pump dealer for more durable than a plastic cabinet. Rheem heat pumps are the only heat pumps manufactured by all efficiently. A Rheem heat pump is no harder than R-22. Now you can save ...
... the major air conditioner manufacturers. It's true! But the most of safe, reliable service, and can afford to operate. Rheem pool heater heat pumps are truly hassle-free. It's that is its operating efficiency compared to the same people who have been in an ... latest eco-friendly R410A refrigerant that with our industry leading pool heating products, we have your Rheem heat pump dealer for more durable than a plastic cabinet. Rheem heat pumps are the only heat pumps manufactured by all efficiently. A Rheem heat pump is no harder than R-22. Now you can save ...
Brochure
Page 4
...than reciprocating compressors. The spiral "rifled" exchanger also helps reduce deposit build-up to use in your Rheem heat pump is the same workhorse that offers a digital or analog control for its heat pump line. In fact, tests have shown that Scroll compressors are up , and increases efficiency by ... worlds together to choose between the 'blue & red swoosh' like it "wears in Rheem air conditioners all around the world! heem Titanium Heat Pumps The new degree of comfort.TM Digital or Analog Rheem is easy to use, has a pool and spa temperature setting as well as full diagnostics...
...than reciprocating compressors. The spiral "rifled" exchanger also helps reduce deposit build-up to use in your Rheem heat pump is the same workhorse that offers a digital or analog control for its heat pump line. In fact, tests have shown that Scroll compressors are up , and increases efficiency by ... worlds together to choose between the 'blue & red swoosh' like it "wears in Rheem air conditioners all around the world! heem Titanium Heat Pumps The new degree of comfort.TM Digital or Analog Rheem is easy to use, has a pool and spa temperature setting as well as full diagnostics...
Brochure
Page 5
... notice. This ensures that all manufacturers belong to AHRI and their published test data is measured for the AHRI Certified logo. Rheem heat pumps give you are third party tested and certified under the AHRI 1160 standard. One of warming your pool water in simple...and open longer. When shopping for a pool heat pump, look for heat pump pool heaters. A Rheem heat pump can possibly obtain is a very efficient way to do the work, it ! We thought you have a Rheem heat pump on the calculation above, a Rheem heat pump delivers efficiencies in Comfort... Your backyard ...
... notice. This ensures that all manufacturers belong to AHRI and their published test data is measured for the AHRI Certified logo. Rheem heat pumps give you are third party tested and certified under the AHRI 1160 standard. One of warming your pool water in simple...and open longer. When shopping for a pool heat pump, look for heat pump pool heaters. A Rheem heat pump can possibly obtain is a very efficient way to do the work, it ! We thought you have a Rheem heat pump on the calculation above, a Rheem heat pump delivers efficiencies in Comfort... Your backyard ...
Brochure
Page 6
... units extend your pool water during the hot summer months! While heating your desired swim temperature. Just the right heat pump for the heat-cool model. No matter what time of year, a Rheem Heat-Cool will achieve your pool, if the Rheem Power Defrost Heat Pump senses damaging ice buildup, the Power Defrost feature redirects a small amount...
... units extend your pool water during the hot summer months! While heating your desired swim temperature. Just the right heat pump for the heat-cool model. No matter what time of year, a Rheem Heat-Cool will achieve your pool, if the Rheem Power Defrost Heat Pump senses damaging ice buildup, the Power Defrost feature redirects a small amount...
Installation Instructions
Page 1
.... Persons not qualified shall not attempt to be maintained in legible condition and kept adjacent to the heat pump pool heater or in an explosion or fire. This manual should be licensed. INSTALLATION & OPERATING INSTRUCTIONS Heat Pump Pool & Spa Heater Model Series 5350, 6350, 6350HC & 8350 NewPrRo-d4u1c0tA R C LIS T E D US FOR YOUR...
.... Persons not qualified shall not attempt to be maintained in legible condition and kept adjacent to the heat pump pool heater or in an explosion or fire. This manual should be licensed. INSTALLATION & OPERATING INSTRUCTIONS Heat Pump Pool & Spa Heater Model Series 5350, 6350, 6350HC & 8350 NewPrRo-d4u1c0tA R C LIS T E D US FOR YOUR...
Installation Instructions
Page 3
...! • Occasional chemical shock dosing of your pool equipment, it is balanced. • Automatic chemical dosing devices and salt chlorinators are usually more efficient in heated water. F) pH Total Alkalinity (PPM) Calcium Hardness (PPM) Fiberglass Pools 68 to 88 7.3 to 7.4 120 to 150 200 to 300 Fiberglass Spas 89 to 104...
...! • Occasional chemical shock dosing of your pool equipment, it is balanced. • Automatic chemical dosing devices and salt chlorinators are usually more efficient in heated water. F) pH Total Alkalinity (PPM) Calcium Hardness (PPM) Fiberglass Pools 68 to 88 7.3 to 7.4 120 to 150 200 to 300 Fiberglass Spas 89 to 104...
Installation Instructions
Page 4
... To Lower Desired Water Temperature Device 26 (Pool or Spa Mode) 12 Wiring 26 To Select Temperature in °C or °F 12 Heater Settings 26 Heat/Cool Operation (Model 6350HC Only) 12 System Start-Up 13 Seasonal Start-Up or Annual Check 13 Summer Shutdown 13 Freeze Protection 13 System Drain...
... To Lower Desired Water Temperature Device 26 (Pool or Spa Mode) 12 Wiring 26 To Select Temperature in °C or °F 12 Heater Settings 26 Heat/Cool Operation (Model 6350HC Only) 12 System Start-Up 13 Seasonal Start-Up or Annual Check 13 Summer Shutdown 13 Freeze Protection 13 System Drain...
Installation Instructions
Page 5
... problems, diabetes, or blood pressure problems should never exceed 104°F (40°C). Persons taking medications which could void the heat pump pool heater warranty. This will cause severe personal injury, death or substantial property damage if ignored. Indicates special instructions on ...installation, operation, or maintenance which will damage the heat pump pool heater and could cause minor personal injury or product or property damage if ignored. Special caution is considered safe...
... problems, diabetes, or blood pressure problems should never exceed 104°F (40°C). Persons taking medications which could void the heat pump pool heater warranty. This will cause severe personal injury, death or substantial property damage if ignored. Indicates special instructions on ...installation, operation, or maintenance which will damage the heat pump pool heater and could cause minor personal injury or product or property damage if ignored. Special caution is considered safe...
Installation Instructions
Page 6
... access, position each 2 inches square) that incorporates a pressurized refrigerant gas in an enclosed area such as gas or oil-fired, this heat pump pool heater could disturb the combustion process of fossil fuel heaters. DO NOT install the unit under the 4 corners of the unit...equipment. The pads are authorized to the circulating pool water. It may operate continuously for quiet operation. This will greatly reduce the unit's heating capacity and efficiency. • This unit features an 'up through the evaporator coil and discharged through the top grill. As with the unions...
... access, position each 2 inches square) that incorporates a pressurized refrigerant gas in an enclosed area such as gas or oil-fired, this heat pump pool heater could disturb the combustion process of fossil fuel heaters. DO NOT install the unit under the 4 corners of the unit...equipment. The pads are authorized to the circulating pool water. It may operate continuously for quiet operation. This will greatly reduce the unit's heating capacity and efficiency. • This unit features an 'up through the evaporator coil and discharged through the top grill. As with the unions...
Installation Instructions
Page 9
...case, should be installed at the unit inlet and outlet to the pool/spa. Unit inlet/outlet connection fittings are NOT interchangeable. Connect the heat pump pool heater in - Fig. 2: Water Connections 4. Model No. 5350 6350/6350HC 8350 VAC in the return water line between the...Table A: Typical System Electrical Power Requirements This unit is pre-wired to the main pool/spa circulation piping. Water Connections CAUTION: The heat pump pool heater inlet and outlet connections are 2-inch PVC unions. See the Plumbing Diagrams beginning on -demand options and other external time...
...case, should be installed at the unit inlet and outlet to the pool/spa. Unit inlet/outlet connection fittings are NOT interchangeable. Connect the heat pump pool heater in - Fig. 2: Water Connections 4. Model No. 5350 6350/6350HC 8350 VAC in the return water line between the...Table A: Typical System Electrical Power Requirements This unit is pre-wired to the main pool/spa circulation piping. Water Connections CAUTION: The heat pump pool heater inlet and outlet connections are 2-inch PVC unions. See the Plumbing Diagrams beginning on -demand options and other external time...
Installation Instructions
Page 10
... position is no remote control system attached. • Water Flow (green lamp): When lit, indicates normal water flow. • Heat Demand (green lamp): When lit, indicates the actual water temperature is applied to , or premature failure of charge or extreme cold ... which could damage or destroy the hermetic motor/compressor. Fig. 3: Indicator Lamps - Controls & Indicator Lamps (Analog Models) Your analog heat pump pool heater incorporates safety controls and indicators to ensure its safe, reliable operation (for a swimming pool temperature. Water Temperature Control: Pool...
... position is no remote control system attached. • Water Flow (green lamp): When lit, indicates normal water flow. • Heat Demand (green lamp): When lit, indicates the actual water temperature is applied to , or premature failure of charge or extreme cold ... which could damage or destroy the hermetic motor/compressor. Fig. 3: Indicator Lamps - Controls & Indicator Lamps (Analog Models) Your analog heat pump pool heater incorporates safety controls and indicators to ensure its safe, reliable operation (for a swimming pool temperature. Water Temperature Control: Pool...
Installation Instructions
Page 11
...If not, see page 10). Turn the control switch to either Pool or Spa to form on humidity). Controls (Digital Models) Your heat pump pool heater incorporates digital safety controls and indicators to 8 minutes. The fan and compressor should illuminate. Fig. 5: Digital Water Temperature ...run but the compressor will run simultaneously. 5. Water Pressure Switch: Prevents operation when the pump is required. The fan will stay OFF (not heating) until weather conditions improve. • Low Pressure (red lamp): When lit, indicates failure in defrost mode. see Fig. 4 below a ...
...If not, see page 10). Turn the control switch to either Pool or Spa to form on humidity). Controls (Digital Models) Your heat pump pool heater incorporates digital safety controls and indicators to 8 minutes. The fan and compressor should illuminate. Fig. 5: Digital Water Temperature ...run but the compressor will run simultaneously. 5. Water Pressure Switch: Prevents operation when the pump is required. The fan will stay OFF (not heating) until weather conditions improve. • Low Pressure (red lamp): When lit, indicates failure in defrost mode. see Fig. 4 below a ...
Installation Instructions
Page 12
... to Fig. 5): • For a pool, maximum 95°F (35°C) • For a spa, maximum 104°F (40°C) The heat/cool model is designed to the desired pool water temperature, the programmed temperature will be displayed for approximately 5 seconds. Then the digital display will then... degree at a time. Once the temperature display mode has been programmed it will return to the actual pool water temperature in the heating mode for a few minutes, the discharge air temperature should be displayed for instructions. The digital display will display the actual pool water...
... to Fig. 5): • For a pool, maximum 95°F (35°C) • For a spa, maximum 104°F (40°C) The heat/cool model is designed to the desired pool water temperature, the programmed temperature will be displayed for approximately 5 seconds. Then the digital display will then... degree at a time. Once the temperature display mode has been programmed it will return to the actual pool water temperature in the heating mode for a few minutes, the discharge air temperature should be displayed for instructions. The digital display will display the actual pool water...
Installation Instructions
Page 13
...Start-Up or Annual Check NOTE: At the beginning of both greater at all. 1. Backwash or otherwise clean the pool filter. Since the heat pump pool heater capacity and efficiency are unless additional circulation is approximately 8°-10°F cooler than the displayed current water temperature. 3. .... Verify that the Board is programmed so that the Digital Board is displaying a temperature and the pool pump is running time of the heating season, or whenever the pool water temperature is generally warmer. If you must lengthen the running and water is circulating properly. 2. DO...
...Start-Up or Annual Check NOTE: At the beginning of both greater at all. 1. Backwash or otherwise clean the pool filter. Since the heat pump pool heater capacity and efficiency are unless additional circulation is approximately 8°-10°F cooler than the displayed current water temperature. 3. .... Verify that the Board is programmed so that the Digital Board is displaying a temperature and the pool pump is running time of the heating season, or whenever the pool water temperature is generally warmer. If you must lengthen the running and water is circulating properly. 2. DO...
Installation Instructions
Page 14
... time should be performed on the evaporator and internal copper pipes? If your unit does not operate, or simply does not heat your heat pump pool heater distributor or pool dealer. • Is water condensing on a periodic basis to solve the problem without the...before calling a service representative. If condensation becomes a problem, optional drain pans are designed to the pool. Maintenance Troubleshooting NOTE: The heat pump pool heater MANUFACTURER IS NOT RESPONSIBLE for the longer running . The following maintenance procedures are available from the unit 8°-10°...
... time should be performed on the evaporator and internal copper pipes? If your unit does not operate, or simply does not heat your heat pump pool heater distributor or pool dealer. • Is water condensing on a periodic basis to solve the problem without the...before calling a service representative. If condensation becomes a problem, optional drain pans are designed to the pool. Maintenance Troubleshooting NOTE: The heat pump pool heater MANUFACTURER IS NOT RESPONSIBLE for the longer running . The following maintenance procedures are available from the unit 8°-10°...
Installation Instructions
Page 15
...on the thermostat, and that it is not leaking. 15 B. Verify that the breaker is set to permit the unit to run long enough to heat properly. C. Use a pool chemistry test kit to confirm there is no chlorine in the condensation. Or, b. On analog units, all 3 lamps ... power problem requiring an electrician. the temperature of condensation (water) during the day can be lost overnight. • Warranty Service • Are rapid heat losses occurring in the pool, verify that all circuit breakers are setting. coils, or any reason, there is a delay • Verify that valves ...
...on the thermostat, and that it is not leaking. 15 B. Verify that the breaker is set to permit the unit to run long enough to heat properly. C. Use a pool chemistry test kit to confirm there is no chlorine in the condensation. Or, b. On analog units, all 3 lamps ... power problem requiring an electrician. the temperature of condensation (water) during the day can be lost overnight. • Warranty Service • Are rapid heat losses occurring in the pool, verify that all circuit breakers are setting. coils, or any reason, there is a delay • Verify that valves ...
Installation Instructions
Page 17
Connections are 2-inch unions. WATER OUT (TO POOL OR SPA) CHEMICAL INTRODUCTION CHECK VALVE Plumbing Diagrams Fig. 6: For systems with pumps of less than 2 HP (under 80 gpm), no external bypass is required. Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators. 17 FILTER WATER IN (FROM POOL OR SPA)
Connections are 2-inch unions. WATER OUT (TO POOL OR SPA) CHEMICAL INTRODUCTION CHECK VALVE Plumbing Diagrams Fig. 6: For systems with pumps of less than 2 HP (under 80 gpm), no external bypass is required. Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators. 17 FILTER WATER IN (FROM POOL OR SPA)
Installation Instructions
Page 18
Adjust the bypass valve to divert a minimum of 2 HP or greater (over 80 gpm), an external bypass is required. Connections are 2-inch unions. Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators. 18 WATER OUT (TO POOL OR SPA) CHEMICAL INTRODUCTION CHECK VALVE FILTER WATER IN (FROM POOL OR SPA) Fig. 7: For systems with pumps of 40 gpm through the heat pump pool heater.
Adjust the bypass valve to divert a minimum of 2 HP or greater (over 80 gpm), an external bypass is required. Connections are 2-inch unions. Plumb the heat pump pool heater AFTER the filter and BEFORE any chlorinators. 18 WATER OUT (TO POOL OR SPA) CHEMICAL INTRODUCTION CHECK VALVE FILTER WATER IN (FROM POOL OR SPA) Fig. 7: For systems with pumps of 40 gpm through the heat pump pool heater.
Installation Instructions
Page 19
Fig. 8: Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 19
Fig. 8: Pool Piping for Heat Pump Pool Heater and Gas Pool Heater 19