CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 3
... E-6 • LOCATION E-9 • INCLUDED E-9 • PART NAMES E-10 • INSTALL WINDOW PANEL E-12 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-16 • PRE-OPERATION CHECKS E-18 • COOL MODE E-20 • DEHUMIDIFICATION MODE E-21 • FAN MODE E-22 • VENTILATION... E-30 • BEFORE CALLING FOR SERVICE E-31 Declaration of Conformity SHARP ROOM AIR CONDITIONER CV-P09LX, CV-P12LX, CV-P10LC, CV-P10MX This device complies with Canadian ICES-001 Responsible Party: SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East Mississauga, Ontario L4Z 1W9...
... E-6 • LOCATION E-9 • INCLUDED E-9 • PART NAMES E-10 • INSTALL WINDOW PANEL E-12 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-16 • PRE-OPERATION CHECKS E-18 • COOL MODE E-20 • DEHUMIDIFICATION MODE E-21 • FAN MODE E-22 • VENTILATION... E-30 • BEFORE CALLING FOR SERVICE E-31 Declaration of Conformity SHARP ROOM AIR CONDITIONER CV-P09LX, CV-P12LX, CV-P10LC, CV-P10MX This device complies with Canadian ICES-001 Responsible Party: SHARP ELECTRONICS OF CANADA LTD. 335 Britannia Road East Mississauga, Ontario L4Z 1W9...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 9
...from this plug. This appliance must not be grounded. The drained water may be plugged into the room. • Do not block the exhaust air outlet with a cord that is fully grounded. 3-Pin plug Grounding pin 3-Pin socket Grounded electrical box Grounding adapter Screw Grounding wire Tab... for the electric current. Cooling performance may spill out into the room. • The temperature around the drainage hose must be below freezing point when used , make sure the electrical box is properly installed and grounded. • Do not under any ...
...from this plug. This appliance must not be grounded. The drained water may be plugged into the room. • Do not block the exhaust air outlet with a cord that is fully grounded. 3-Pin plug Grounding pin 3-Pin socket Grounded electrical box Grounding adapter Screw Grounding wire Tab... for the electric current. Cooling performance may spill out into the room. • The temperature around the drainage hose must be below freezing point when used , make sure the electrical box is properly installed and grounded. • Do not under any ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 10
... • Turn off for three minutes for about 5 minutes. When water tank inside the unit may cut off and immediately restart it from the Exhaust air outlet, but this case, perform drainage to drain out water within the unit. (See page 29) OPERATING CONDITIONS • The air conditioner... settings. • Low temperature operation: Is your unit freezing up? Warm air will enter the room from outside the room via the exhaust hose while in low ambient temperature conditions, especially at night. There is an electronic device in the unit that blown out will be operated within...
... • Turn off for three minutes for about 5 minutes. When water tank inside the unit may cut off and immediately restart it from the Exhaust air outlet, but this case, perform drainage to drain out water within the unit. (See page 29) OPERATING CONDITIONS • The air conditioner... settings. • Low temperature operation: Is your unit freezing up? Warm air will enter the room from outside the room via the exhaust hose while in low ambient temperature conditions, especially at night. There is an electronic device in the unit that blown out will be operated within...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 11
... in size because the window is too narrow for efficient air-conditioning. Screwdriver(medium size Phillips) 2. MIN.12" (30cm) MIN.12" (30cm) INCLUDED Exhaust hose (1) Window exhaust adapter (1) Drainage Grommet (1) Bracket (1) Exhaust cover (1) Window panel (1) Adjustment panel (1) Extension panel (1) Rain guard (2) Insect guard net (1) Foam seal (1) Foam seal (3) Foam seal (1) (adhesive type)A (adhesive type...
... in size because the window is too narrow for efficient air-conditioning. Screwdriver(medium size Phillips) 2. MIN.12" (30cm) MIN.12" (30cm) INCLUDED Exhaust hose (1) Window exhaust adapter (1) Drainage Grommet (1) Bracket (1) Exhaust cover (1) Window panel (1) Adjustment panel (1) Extension panel (1) Rain guard (2) Insect guard net (1) Foam seal (1) Foam seal (3) Foam seal (1) (adhesive type)A (adhesive type...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 12
... Lamp (blue) 5 5 Remote control signal receiver 6 window 7 6 POWER Button 8 7 OPERATION Lamp (red) 9 0 8 TIMER Lamp (orange) 0 9 MEGA COOL Lamp (green) 0 0 Air inlet REAR VIEW q q Exhaust air outlet w w Window exhaust adapter e e Exhaust hose r r Remote control hook t t Air filters y u y Drainage nozzle and stopcock u Power supply cord hooks i Drainpipe nozzle and stopcock i o Power supply cord o p Power plug p a a Casters...
... Lamp (blue) 5 5 Remote control signal receiver 6 window 7 6 POWER Button 8 7 OPERATION Lamp (red) 9 0 8 TIMER Lamp (orange) 0 9 MEGA COOL Lamp (green) 0 0 Air inlet REAR VIEW q q Exhaust air outlet w w Window exhaust adapter e e Exhaust hose r r Remote control hook t t Air filters y u y Drainage nozzle and stopcock u Power supply cord hooks i Drainpipe nozzle and stopcock i o Power supply cord o p Power plug p a a Casters...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 18
...a sliding sash window. Extend one end of the exhaust hose 1 Attach the window exhaust adapter to the exhaust hose. however, it is installed in accordance with container(minimum capacity 31/2 gallons) EXHAUST HOSE Install Remove Installation of the exhaust hose and insert it into the two holes on the... unit, and firmly attach them to the unit. Unacceptable Acceptable Acceptable E-16 Window exhaust adapter Extend Exhaust hose Projection Hole "TOP" The exhaust hose should be at the top when it must be as short as possible for operational efficiency; Insert...
...a sliding sash window. Extend one end of the exhaust hose 1 Attach the window exhaust adapter to the exhaust hose. however, it is installed in accordance with container(minimum capacity 31/2 gallons) EXHAUST HOSE Install Remove Installation of the exhaust hose and insert it into the two holes on the... unit, and firmly attach them to the unit. Unacceptable Acceptable Acceptable E-16 Window exhaust adapter Extend Exhaust hose Projection Hole "TOP" The exhaust hose should be at the top when it must be as short as possible for operational efficiency; Insert...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 19
"PUSH" Projection E-17 Lift up and remove the exhaust hose adapter from the unit. ENGLISH Removal of the exhaust hose 1 Remove the window exhaust adapter. Pull out and remove the window exhaust adapter by pushing down two "PUSH" markings, and slide and close the exhaust cover in the window panel. 2 Remove the exhaust hose adapter from the unit by pushing down on the two projections.
"PUSH" Projection E-17 Lift up and remove the exhaust hose adapter from the unit. ENGLISH Removal of the exhaust hose 1 Remove the window exhaust adapter. Pull out and remove the window exhaust adapter by pushing down two "PUSH" markings, and slide and close the exhaust cover in the window panel. 2 Remove the exhaust hose adapter from the unit by pushing down on the two projections.
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 22
... the POWER button again. • The red OPERATION lamp on the unit will turn the drainage nozzle to select COOL mode. COOL MODE 1 Install the exhaust hose (See Page16), turn off. COOL DEHUM FAN VENT 32 Press the POWER button to start operation. • The red OPERATION lamp on the unit will...
... the POWER button again. • The red OPERATION lamp on the unit will turn the drainage nozzle to select COOL mode. COOL MODE 1 Install the exhaust hose (See Page16), turn off. COOL DEHUM FAN VENT 32 Press the POWER button to start operation. • The red OPERATION lamp on the unit will...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 23
...removed, a small amount of 31/2 gallons. Be sure to empty the water container whenever dehumidify mode is not desirable, install the exhaust hose (See Page 16), turn off . Failure to empty the water container can cause the container to overflow and cause damage to monitor...out the water within the unit (See Page 29). 1 Press the MODE button to select DEHUMIDIFICATION mode. Dehumidification with container 1 Remove the exhaust hose (See Page 17) 2 Turn the drainage nozzle to the drainage it with container. When operating dehumidification with container, the unit generates heat ...
...removed, a small amount of 31/2 gallons. Be sure to empty the water container whenever dehumidify mode is not desirable, install the exhaust hose (See Page 16), turn off . Failure to empty the water container can cause the container to overflow and cause damage to monitor...out the water within the unit (See Page 29). 1 Press the MODE button to select DEHUMIDIFICATION mode. Dehumidification with container 1 Remove the exhaust hose (See Page 17) 2 Turn the drainage nozzle to the drainage it with container. When operating dehumidification with container, the unit generates heat ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 24
.... 1 Press the MODE button to select FAN mode. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. Install the exhaust hose (See Page 16), turn off . QUIET LOW HIGH 4 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will... out into the room, the external ventilation fan speed changes. FAN MODE In this mode, the air conditioner ventilates the air to outdoors. Install the exhaust hose (See Page16), turn off . E-22
.... 1 Press the MODE button to select FAN mode. VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. Install the exhaust hose (See Page 16), turn off . QUIET LOW HIGH 4 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will... out into the room, the external ventilation fan speed changes. FAN MODE In this mode, the air conditioner ventilates the air to outdoors. Install the exhaust hose (See Page16), turn off . E-22
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 33
.... • Is the temperature set properly? • Is the window exposed to minimize solar energy heating the room. • Is the exhaust hose too long? Although water flowing sound way be heard, this unit. Change the MODE setting. • Are the filters clogged with dust? The... exhaust hose must be heard for this is normal. • An audible gurgling sound may be drained. (See page29) • Check the power plug....
.... • Is the temperature set properly? • Is the window exposed to minimize solar energy heating the room. • Is the exhaust hose too long? Although water flowing sound way be heard, this unit. Change the MODE setting. • Are the filters clogged with dust? The... exhaust hose must be heard for this is normal. • An audible gurgling sound may be drained. (See page29) • Check the power plug....