Get support for Campbell Scientific WINDSONIC1

Campbell Scientific WINDSONIC1 Support Question

Campbell Scientific WINDSONIC1 Support Question

Find answers below for this question about Campbell Scientific WINDSONIC1.
Need a Campbell Scientific WINDSONIC1 manual? We have 1 online manual for this item!
Question posted by bouadilasalwa on February 9th, 2017

Windsonic 1

WindSonic Option 1 This probe communicates with the PC via RS232. I want to use this probe on a CR5000 chain (on the Short Cut of this chain there is only the WindSonic Option 4 via SD1-12 output). Do you have an idea about the configuration by CRBasic of this probe is what it is possible to use.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Campbell Scientific WINDSONIC1 Manual Pages

WINDSONIC 2-D Sonic Wind Sensors - Page 5

... for SDI-12 Output 15 7.4.1 Example CR10X (Edlog) Datalogger Program for Measuring a WindSonic4 17 7.4.2 Example CR200(X) Datalogger Program for Measuring a WindSonic4 20 7.4.3 Example CR800 Datalogger Program for Windows (SCWin) to the printed version of this document. Overview 7 6. Quickstart 2 4.1 Siting ...2 4.2 Mount the Sensor 2 4.3 Use Short Cut Program Generator...
WINDSONIC 2-D Sonic Wind Sensors - Page 6

...0 to find True North A-2 A-4. WindSonic1 Output Frequencies 10 7-2. CRBasic Datalogger Operating Systems that the WindSonic1 has the newer settings..... 10 7-1. Updating an Older Program for CR1000/SDM-SIO1 Program Example 14 ii WindSonic mounted on an Edlog table-based datalogger using pn 17837 3 6-1. SDI-12 Transparent Mode on a CM202 using control port 8 and changing the SDI...
WINDSONIC 2-D Sonic Wind Sensors - Page 7

Datalogger Operating Systems that Support the SDI-12 "aRo!" Command 16 7-10. Wiring for CR800 Program Example 21 9-1. Example Datalogger Program Diagnostic Codes 27 iii WindSonic Data Format Option 15 7-9. Wiring for CR10(X) Program Example 17 7-11. Table of Contents 7-8. Wiring for CR200(X) Program Example 20 7-12. Gill WindSonic Diagnostic Codes 27 9-2.
WINDSONIC 2-D Sonic Wind Sensors - Page 9

... programs and Short Cut 3.0 or older. The SDI-12 standard specifies that can be read by Gill Instruments, Ltd. The WindSonic1 outputs an RS-232 signal that an SDI-12 sensor must be able to traditional mechanical cup and vane or propeller and vane anemometers. Introduction The WindSonic1 and WindSonic4 are acceptable. 1 Before installing the WindSonic, please study...
WINDSONIC 2-D Sonic Wind Sensors - Page 10

... 17387). start at the connection end of the obstruction. The mounting kit includes a 34.93 cm (13.75 inch) length of the WindSonic, inspect the packaging and contents for its use inside buildings. 3. However, this information against the shipping documentation (see FIGURE 4-1). 2 Thread the connector end of the cable through the tubing...
WINDSONIC 2-D Sonic Wind Sensors - Page 12

... 4.3 Use Short Cut Program Generator for Windows (SCWin) to use Campbell Scientific's SCWin. Open Short Cut and click on New Program. 2. This section provides information about using Short Cut with the WindSonic4. See Section 7, Operation, for programming the datalogger to measure the WindSonic is to Program Datalogger and Generate Wiring Diagram The simplest method for WindSonic1...
WINDSONIC 2-D Sonic Wind Sensors - Page 14

Select the outputs and then select finish. 6. WindSonic Two-Dimensional Sonic Anemometer 5. Wire according to the wiring diagram generated by SCWin Short Cut. 6
WINDSONIC 2-D Sonic Wind Sensors - Page 15

... dataloggers. This manual serves as a guide for a specific application. Option 1 WindSonic (WindSonic1) outputs data using the SDI-12 interface. Campbell Scientific does not recommend using the CR200(X)series, CR5000, or any of orthogonally oriented transducers to a PC running Gill's PC support software. SDI-12 is available in the manual published by processor-based sensors and digital...
WINDSONIC 2-D Sonic Wind Sensors - Page 16

...address factory set to 0 Output Variables: wind direction, wind speed, and diagnostic or ux, uy, and diagnostic (WindSonic4 only) Measurement Frequency: 40 Hz block averaged to a programmable output frequency, factory set to 60 m s-1 ±2% @ 12 m s-1 0.01 m s-1 6.3 General Specifications Output Signal: RS-232 (WindSonic1) SDI-12 version 1.3 (WindSonic4); WindSonic Two-Dimensional Sonic...
WINDSONIC 2-D Sonic Wind Sensors - Page 17

...bits, no parity (F1) • RS-232 interface (E3) • Analog output 0 to 30 m s-1 (S4) - WindSonic Two-Dimensional Sonic Anemometer 6.4 Campbell Scientific Factory Default Settings for the WindSonic1 The default settings for a WindSonic1 with the newer settings. 9 Sensors with older programs or Short Cut 3.0 or older. does not apply • Analog wrap around 0 to 360 degrees...
WINDSONIC 2-D Sonic Wind Sensors - Page 18

... FIGURE 6-1. The factory setting for example, 1 output per second. WindSonic1 Output Frequencies Output Seconds Frequency (Hz) Per Output (s) 4 0.25 2 0.5 1 1 0.5 2 0.25 4 10 The data output frequency of the WindSonic4 cannot be set to five discrete values (see TABLE 7-1) using Gill's PC support software and the RS-232 WindSonic to best mimic a mechanical anemometer, the...
WINDSONIC 2-D Sonic Wind Sensors - Page 19

... uses four wires as a single communications (COMn) port. TABLE 7-3 describes the connections between a WindSonic1 and SDM-SIO1. WindSonic Two-Dimensional Sonic Anemometer 7.2 Wiring 7.2.1 Serial Wiring (COMn) CRBasic dataloggers (CR800 series, CR1000, and CR3000) support serial communications with a RS-232 interface depends on the datalogger control ports. WindSonic1 to the Electronic...
WINDSONIC 2-D Sonic Wind Sensors - Page 20

... recorders (TABLE 7-4). The datalogger and WindSonic1 each other and will occur if the WindSonic is 0. A no power, or the datalogger and WindSonic clocks have drifted out of the datalogger operating system (OS) did not support serial communication using SDI-12. The CRBasic dataloggers (CR800-series, CR1000, and CR3000) use by the WindSonic1 at the scan interval. TABLE 7-5 lists...
WINDSONIC 2-D Sonic Wind Sensors - Page 21

...Communications and SerialInRecord() Datalogger Model CR800-series CR1000 CR3000 Operating System 4.0 or later 13.0 or later 6.0 or later 7.3.1 Example CR1000 Datalogger Program for CR1000 Example Program Description WindSonic RxD WindSonic...") Totalize (1,n,IEEE4,diag10) 13 WindSonic Two-Dimensional Sonic Anemometer TABLE 7-5. Wiring for Measuring a WindSonic1 using COMn Port TABLE 7-6.
WINDSONIC 2-D Sonic Wind Sensors - Page 22

...Sec,3,0) 'Get data from WindSonic. Wiring for Measuring a WindSonic1 using an SDM-SIO1 TABLE 7-7. wind_direction = windsonic(1) wind_speed = windsonic(2) diag = windsonic(4) checksum_flg = ( (...WindSonic RxD WindSonic TxD Power RS-232/Power reference Shield Color Green White Red Black Clear CR1000 TX-Z RX-A +12 Vdc G G 'CR1000 Series Datalogger Dim in_bytes_str As String * 21 Dim windsonic...
WINDSONIC 2-D Sonic Wind Sensors - Page 23

... SDM address set To 8. Section 4.3, Use Short Cut Program Generator for the WindSonic4. WindSonic Data Format Option Option (o) 0 1 Output wind direction wind speed diagnostic ux wind...SDI-12 Output A program for the WindSonic4 can be written using SCWin to create a datalogger program and wiring diagram for Windows (SCWin) to floats. TABLE 7-8. The WindSonic4 updates the SDI-12 output ...
WINDSONIC 2-D Sonic Wind Sensors - Page 34

...output data, or send a nonzero diagnostic, return it for repair 26 The WindSonic4 will respond with a cloth and mild detergent. Do no user-serviceable parts on the WindSonic. The WindSonic4 will respond with the current SDI-12... are no use solvents and avoid scratching or damaging the matching layers. Keep the transducer paths clear of the transducers. Should the WindSonic be gently ...
WINDSONIC 2-D Sonic Wind Sensors - Page 41

...; older sensor cables had two white heat shrink labels. Old CR1000 Program (Section 6.1 of the WindSonic1 sensor were changed from the old and new WindSonic manuals. The communication baud rate has been changed to 38,400 baud or Short Cut version 3.0 or older. CAUTION Sensors with newer settings will NOT work with the new settings...
WINDSONIC 2-D Sonic Wind Sensors - Page 42

... a WindSonic1 With the New Settings New CR1000 Program (Section 7.3.1) (Public variables change . Scan (1,Sec,3,0) 'Get data from WindSonic. SerialInRecord (Com1,in_bytes_str,&h02,0,&h0D0A,nmbr_bytes_rtrnd,01) SplitStr (windsonic(),in_bytes_str,",",4,4) 'Split the string and convert to 8. Data table structure stays the same.) Public windsonic(4) Alias windsonic(1) = wind_direction...
WINDSONIC 2-D Sonic Wind Sensors - Page 43

...(),in_bytes_str,",",4,4) 'Split the string and convert to floats. Updating an Older Program for Measuring a WindSonic1 With the New Settings New CR1000 SDM-SIO1 Program (from WindSonic. Data table structure stays the same.) Dim windsonic(4) As String Public wind_direction Public wind_speed Public diag Public nmbr_bytes_rtrnd Units wind_direction = degrees Units wind_speed = m/s Units diag...
Ask a New Question
Use the box below to post a new question about this Campbell Scientific product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific WINDSONIC1 manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.