Get support for Fluke 1550B

Fluke 1550B Support Question

Fluke 1550B Support Question

Find answers below for this question about Fluke 1550B.
Need a Fluke 1550B manual? We have 3 online manuals for this item!
Question posted by richardbossert on March 16th, 2017

Battery Replacement

How do you get into this thing?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Fluke 1550B Manual Pages

Fluke 1550B MegOhmMeter Datasheet - Page 1

... tests. It can name for quick recall later • High-capacity rechargeable batteries • Includes Quicklink 1550B Software and Optical Interface cable for down- tive maintenance. Heavy-duty leads,... soft- Fluke 1550B MegOhmMeter Digital insulation testing up to 1 Tera-Ohm • Warning voltage function alerts the user that user can be used for tester and accessories • Includes...
Fluke 1550B MegOhmMeter Datasheet - Page 2

... running Windows® 95, 98, Me, 2000, NT4.0 Two-year warranty Included accessories Test leads and low leakage probes Alligator clips Interface adapter and cable Quicklink 1550B PC software Line cord Soft carrying case with waterproof bottom User's manual CD with battery) 170 mm x 242 mm x 330 mm (6.7 in x 9.5 in x 13.0 in) 4 kg...
FE 1550B Users Manual - Page 1

All product names are trademarks of their respective companies. All rights reserved. ® 1550B MegOhmMeter Users Manual PN 3001289 August 2003, Rev. 1, 6/05 © 2003, 2005 Fluke Corporation.
FE 1550B Users Manual - Page 2

...site at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of this warranty may not apply to a Fluke authorized service center within the warranty period....buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to extend a greater or different warranty on the date of any provision of a defective ...
FE 1550B Users Manual - Page 4

1550B Users Manual ii
FE 1550B Users Manual - Page 5

... Under Test 10 9. Pushbuttons 5 3. Standard Items Provided 2 2. Surface Leakage Current 8 6. Guard Terminal Connection 9 7. IR Port on 1550B MegOhmMeter 18 iii Display Features 6 4. List of Figures Figure Title Page 1. Improved Guard Terminal Connection 9 8. List of Replacable Parts 21 3. 1550B Accessories 21 List of Tables Table Title Page 1. Symbols 4 2.
FE 1550B Users Manual - Page 6

1550B Users Manual Cover Terminals Display (LCD) Pushbuttons Safety Shutter IR Port PIRODRAT UP FUNCTION OONF/F SCROLL DOWN ENTER TEST Latch Handle Fluke 1550B MegOhmMeter asw16F.EPS iv
FE 1550B Users Manual - Page 7

... with user settable ID tag ⇒ Breakdown voltage indication ⇒ Rechargeable lead-acid battery ⇒ Auto shutoff after 30 minutes of inactivity ⇒ Infrared (IR) port for... V Pollution Degree 2 standards. Register your Meter at : www.fluke.com. 1550B MegOhmMeter Introduction The Fluke 1550B MegOhmMeter (hereafter "the Meter") is designed to get the location of the nearest...
FE 1550B Users Manual - Page 8

The supplied test leads are for use with this instrument only. Do not use with other equipment 2 1550B Users Manual Unpacking the Meter The Meter comes with interface cable G CD containing Users Manual H CD containing FlukeView Forms Basic I Software License Agreement J Registration Card K ...
FE 1550B Users Manual - Page 9

...shock or personal injury: • Use the Meter only as specified in this manual. Replace damaged leads. MegOhmMeter Safety Information Safety Information XW Warning Before and after testing, confirm that...use the Meter with any parts or cover removed. • Use only Fluke approved replacement parts, and accessories as specified in this manual. • Do not use the Meter if the ...
FE 1550B Users Manual - Page 10

... version, and starts in distribution systems with UL3111-1, CAN/CAS C22.2 No.1010.1 for Test and Measurement Equipment Risk of specified accuracy. Interference is present. 1550B Users Manual Symbols Symbols on the Meter. Do not use in the Test Voltage mode. Symbols P Conforms to turn the Meter on and off the...
FE 1550B Users Manual - Page 12

...Displayed readings may be outside the specified accuracy range. Display Features Charging the Battery XW Warning To avoid possible electric shock or personal injury, disconnect the ...Digital display of insulation resistance. Potentially hazardous voltage is present at the test terminals. 1550B Users Manual Understanding the Display Display annunciators are shown and described in Ramp mode. ...
FE 1550B Users Manual - Page 14

... Meter to read a lower resistance than it should. In this case, there is measured between the + and − output connections. Shield ( ) ( ) Surface Leakage Current Figure 5. 1550B Users Manual Using the Guard Terminal Note Insulation resistance is a leakage current along the surface of the inner insulation near the end of the insulation...
FE 1550B Users Manual - Page 16

1550B Users Manual Making Measurements Connecting to the Circuit Under Test XW Warning To avoid possible electric shock or ...test, results in the terminals shown (Figure 8), and connect the test leads to the Circuit Under Test ASW09F.EPS Note The 1550B is shown on the display, disconnect test leads and remove power from the circuit under test and discharge circuit capacitance before testing a...
FE 1550B Users Manual - Page 18

... next function. Instead press the H button to go to increment and decrement the voltage. TV=xxxxV appears flashing in the upper-right of the display. 4. 1550B Users Manual Programming a Test Voltage To set a test voltage in between the pre-set voltage selection. V 500V 0M 00M G 0G M 00G 00k T 0 GT kM Test...
FE 1550B Users Manual - Page 20

1550B Users Manual Polarization Index (PI) As part of the insulation test, the Meter measures and stores capacitance when appropriate. Since, by storing the test results ...
FE 1550B Users Manual - Page 22

... future use . as described in the next procedure. The Meter includes enough memory to charged-circuit capacitance or from the presence of an external voltage. 4. 1550B Users Manual Following termination of an insulation test the Meter beeps when a potentially hazardous voltage remains on the display. Storing the Test Results Upon completion...
FE 1550B Users Manual - Page 26

...or personal injury, do not attempt to repair or service your stored test results. There are no user-replaceable parts inside the Meter. Cleaning XW Warning To avoid possible electric shock or personal injury, remove excess ...Principle of your Meter beyond what is described in this manual. 1550B Users Manual Note Individual test locations cannot be deleted, however, they can be overwritten.
FE 1550B Users Manual - Page 27

...Infrared Cable Assembly Users Manual CD English Users Manual Quick Reference Card Table 3. 1550B Accessories Accessories Extended Test Lead Set, 25 feet (7.6 meters) Part No. 1642584 1642591 1642600...21 MegOhmMeter Maintaining the Meter Replaceable Parts and Accessories Table 2 lists the replaceable parts that are available for use with the Meter. List of Replaceable Parts Parts Test Lead -...
FE 1550B Users Manual - Page 28

... NP2.8-12 85 V to be charged more frequently. 75 mm x 105 mm 12 V lead-acid rechargeable battery. The protective earth terminal (ground pin) is for added plug retention only. 170 mm x 242 mm x 330 mm (6.7 in. 1550B Users Manual Specifications General Specifications Display Power Charger Input (AC) Dimensions (H x W x L) Weight Temperature (operating) Temperature...

Similar Questions

1550b 2016 Model
Wouldn't charge, so I replaced the battery with a correct new one. Let it properly charge and now th...
(Posted by brianrobcox3 1 year ago)
Fluke 787 Battery Replaced.
When I switch the instrument on it just displays "uncal"... What can I do...?
(Posted by allatseaagain 2 years ago)
Operation
We have 2 fluke 1550B that ran out of batteries and were not placed on charge for about 2 weeks and ...
(Posted by johnnyt3000 7 years ago)
Suitable Replacement Battery For My Fluke 744
I have the old Fluke BP7217 ni-cad battery. What is an acceptable replacement batttery for my Fluke ...
(Posted by cwoodard 8 years ago)
Battery
we have a 1550B megohmmeter but the battery does not hold a charge, how can we get a new battery for...
(Posted by lxblack 9 years ago)
Ask a New Question
Use the box below to post a new question about this Fluke product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1550B manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.