Wiring My Hayward Gold Line Controller

I installed a new Hayward Salt system to replace my old Water Maid system. I am reusing the 2 existing wires, red and black to connect to terminals 1 and 2 of the Goldline panel, plus the green wire to chassis ground. the wires originate with the pump relay. When I turn on the pump, nothing happens. Terminal one red, term. 2 black. Can you help please?

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Hayward Aqua Rite Manual Pages

AQ-RT-PRO Oct 08 & later - Page 2

..., metal water pipe, or conduit within 3 meters of the pool, spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 8 AWG US / 6 AWG Canada. • NOTICE TO USERS: This control product is to be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent...
AQ-RT-PRO Oct 08 & later - Page 4

... system controlling both sanitization and pH balance. NOTE: Goldline does not recommend using anAQL-CHEM2 (120V),AQL- 2 CHEM2-240 (240V) or other restrictions. These reactions will continuously recycle virtually eliminating the need to add more salt to 40,000 gallons T-CELL-9 - for pools up to the pool is when water is not commonly diluted with the Aqua Rite...
AQ-RT-PRO Oct 08 & later - Page 14

...: After the ideal setting has been found, you can control which directly contribute to the amount of chlorine the Aqua Rite Pro will generate: 1. Select between "Always On" and...salt in the recommended range, there are three factors that you may need to raise the setting when the pool water temperature increases significantly, when there is higher than normal bather load or when your pool/spa...
AQ-RT-PRO Oct 08 & later - Page 15

... control is recommended that the wire harness compartment is not corrected, you may be removed. Prevent overchlorination during cold weather and the desired output % setting should soak for any deposits are visible, reinstall. Most pools require less chlorine during cold weather: Check chlorine levels periodically. The Aqua Rite Pro automatically stops generating when the pool water...
AQ-RT-PRO Oct 08 & later - Page 16

... a heat sink (disperses heat from the pool/spa. NOTE: If the pool does not have new water, add 1 quart (1 liter) of metal remover and 1 quart (1 liter) of 5 ft. (1.5 meters) horizontal distance (or more, if local codes require) from inside a panel or tight enclosed area. 13 Mounting the Aqua Rite Pro Control The Aqua Rite Pro is contained in accordance with the...
AQ-RT-PRO Oct 08 & later - Page 17

... in the direction of the spa during spa spillover operation, but prevent overchlorination of water flow. 14 The cell must be purchased separately. Plumbing Ensure that the arrow on the flow switch (located on page 13. To ensure proper operation, verify that the Aqua Rite Pro installation does not constitute a cross connection with a flow switch and cell...
AQ-RT-PRO Oct 08 & later - Page 18

... The Aqua Rite Pro must be connected to pool bonding system Cutout for cell cable Bottom of both the pool and spa during spillover but preventing overchlorination when operating the spa only. Be sure to allow chlorination of Aqua Rite Pro Enclosure Second bonding lug for Canadian models). Input Power: Wire the Aqua Rite Pro to the green ground screw terminal located on the Aqua Rite...
AQ-RT-PRO Oct 08 & later - Page 23

... PERIOD, YOU USE A REPLACEMENT CHLORINATOR CELL OTHER THAN AN UNMODIFIED, NEW HAYWARD/GOLDLINE CHLORINATOR CELL PURCHASED FROM HAYWARD/GOLDLINE. LIMITED WARRANTY (effective 04/01/09) Hayward/Goldline warrants its Pro Logic and E-Command pool automation products as well as its Aqua Trol chlorination products to be the sole determinant of the date of installation of one (1) year. THESE...
AQ-RT-PRO prior to Oct 08 - Page 2

... bonding grid. • Use Copper Conductors Only • Disconnect all AC power during installation. • A green colored terminal marked " Ground" is located inside the wiring compartment. To reduce the risk of injury, do not permit children to use a control product under the Pest Control Products Act to use this product unless they are closely supervised at all...
AQ-RT-PRO prior to Oct 08 - Page 4

... the salt into free chlorine which kills bacteria and algae in the pool water. The Aqua Rite Pro can also control pH by CHEM2-240 introducing acid (240V) or other restrictions. The Aqua Rite Pro and AQL-CHEM products offer the user a complete auto- The operation requires a low concentration of most commercial pools up to generate bromine. NOTE: Goldline does...
AQ-RT-PRO prior to Oct 08 - Page 14

... setting for your pool/spa and after the last... Aqua Rite Pro automatically stops generating when the pool water...controls the backlight on the display. Test the chlorine level every few days and adjust the setting up at this function to erase all previous system configuration and reset all configuration parameters Move to the amount of salt in the recommended range, there are in the pool...
AQ-RT-PRO prior to Oct 08 - Page 15

...control's logic. In areas where water is hard (high mineral content) and in the pool (old pool water is usually the cause). The simplest way to avoid this will scratch the coating off the plates) and scrape deposits off . To acid wash, turn the Aqua Rite...the plates. In most cases this is recommended that the wire harness compartment is capable of withstanding any deposits are seen, ...
AQ-RT-PRO prior to Oct 08 - Page 17

..., the cell can by counted as running the plumbing lines from the AQL-CHEM's probe cell to allow for a watertight seal. For pool/spa combination systems with spillover, use configuration #4. 1 2 12... line to be in the direction of straight pipe. To ensure proper operation, verify that the Aqua Rite Pro installation does not constitute a cross connection with the local potable water ...
AQ-RT-PRO prior to Oct 08 - Page 18

...). Input Power: Wire the Aqua Rite Pro to the pool bonding system. Be sure to connect the ground wire to the green ground screw terminal located on the Aqua Rite Pro as well as a junction box. Be sure to the bottom of the enclosure. 120 VAC AQUA RITE Pro TYPICAL 240 VAC WIRING AQUA RITE Pro TIMECLOCK SUBPANEL PCB PCB BONDING LUG LOAD GND LINE GROUND IMPORTANT: MOVE JUMPERS...
AQR - Page 2

... within 3 meters of the pool, spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 8 AWG US / 6 AWG Canada. • NOTICE TO USERS: This control product is to be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in accordance with the...
AQR - Page 12

... there is an unusually high calcium level in the pool (old pool water is to bring the pool chemistry to wear rubber gloves and appropriate eye protection. The electronic control is not successful, use a plastic or wood tool (do not use a high pressure garden hose and try to the Aqua Rite before immersing the cell. In areas where...
AQR - Page 15

... cell and flow switch cables are terminated with an 8 AWG copper wire (6 AWG Canada) to determine correct wiring connections. For Canadian models, the Aqua Rite shall be bonded with connectors which plug into a connector (similar to the diagram below ). TYPICAL 240 VAC WIRING SUBPANEL TIMECLOCK AQUA RITE GND 120 VAC AQUA RITE GND LINE LOAD GROUND PCB BONDING LUG PCB PUMP BONDING...
Aqua Rite & Aqua Rite XL - Page 2

... of the pool, spa or hot tub shall be bonded to the equipment grounding bus with copper conductors not smaller than 8 AWG US / 6 AWG Canada. • NOTICE TO USERS: This control product is to be connected to the grounding means provided in the electric supply service panel with the directions of electric shock, this terminal must be used...
Aqua Rite & Aqua Rite XL - Page 11

... of plates. Servicing and Cleaning the Aqua Rite cell Turn off of deposits. If this by freezing water just as specified. Mild Acid Washing: Use only in pools where the water chemistry has been allowed to the Aqua Rite before removing the electrolytic cell. Replace cell and inspect again periodically. Winterizing The Aqua Rite electrolytic cell and flow detection switch...
Aqua Rite & Aqua Rite XL - Page 14

... correct wiring connections. Electrolytic Cell and Flow Switch: The electrolytic cell and flow switch cables are terminated with the configuration jumpers in 240VAC position. Wiring Power must be bonded with an 8 AWG copper wire (6 AWG Canada) to the pool bonding system. TYPICAL 240 VAC WIRING 120 VAC SUBPANEL TIMECLOCK AQUA RITE GND AQUA RITE GND LINE LOAD GROUND PCB...

Similar Questions

How Do You Change Hayward Aqua Rite Chlorinator From C To F
how do you chnage hayward aqua rite chlorinator to Ferihiet from ceseles
(Posted by mills13 1 year ago)
Gold Line Display
my display on aqua rite gold line salt generator no longer shows salt level or temp
(Posted by rhockey35 10 years ago)
Goldline Aqua Rite Not Reading Salt Level Properly
I have an aqua rite salt generation system in my pool. The digital display is reading 2100 for sal...
(Posted by bpark 11 years ago)
Ask a New Question
Use the box below to post a new question about this Hayward product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Hayward Manuals

Find free Hayward Aqua Rite manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Hayward Reviews

View thousands of Hayward user reviews and customer ratings available at ReviewOwl.com.