Question About Mega Arm/mega Tower 'arm Motion.'

What exactly is the "sensor/trigger" for the Mega Arm/ Mega Tower Arm to rise and fall? Can the unit be activated by a remote, overriding the Hall Effect Sensor? What does the remote control for the unit activate it to do? Do you know of any incidents where the arm has been known to fall and cause injury or damage? 

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related LiftMaster MEGA ARM / MEGA ARM TOWER Manual Pages

MATDCBB Green Control Board V.6.4 or newer Manual - Page 1

... # MBAT). Radio Receiver Included The Chamberlain Group, Inc. 845 Larch Avenue Elmhurst, Illinois 60126-1196 www.liftmaster.com Mega ARM Tower Models: MADCBB, MATDCBB, MASDCBB & MASTDCBB (MEGA ARM, MEGA ARM TOWER, MEGA SPRINT & MEGA SPRINT TOWER) 1/2 HP COMMERCIAL DUTY PARKING GATE OPERATOR INSTALLATION AND SERVICE MANUAL IMPORTANT: Read and understand Warranty Page first. Batteries (included...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 2

... LOOP SENSOR LOCATIONS Free Exit Operation 15 Entry With Access Control Device 15 Dual Direction 15 TRAP INSTRUCTIONS 16 SEQUENCE ACCESS MANAGEMENT SYSTEM (SAMS) SAMS With Other Operators 17 SAMS Two Mega Arms with "Memory 17 CONTROL BOARD LAYOUT Input Locations 18 MEGA ARM UL PARTS LIST Part Numbers and Descriptions 19 Parts Shipped 19 Mega Arm Tower...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 3

... the warnings that the optional heater is installed. uses magnetic (Hall Effect) sensors to open and close travel if tail-gating is sensed at close travel motions. • No limit switches to fail - TENCIA • Ability to STOP arm in open a slide/swing gate first then raises arm. AVERTISSEMENT • Direct drive gear reducer eliminates many features that...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 4

...Slide Gate Operator Primary Type A Secondary Type B1, B2 or D Swing & Gate Barrier (Arm) Operator Primary Type Secondary Type A or C A, B1, B2, or C Class III... as a multi-family housing unit (five or more single family units) hotel, garage, retail store or other restricted...operator open and close . That means that is prevented via supervision by UL325 for a contact sensor....
MATDCBB Green Control Board V.6.4 or newer Manual - Page 5

... a separate access opening. b. The pedestrian access opening and closing to potential hazards. 3. c. Activation of the gate. For a gate operator utilizing a non-contact sensor: a. Care shall... is appropriate for exposed rollers. 5. One or more contact sensors shall be located where the risk of a vertical barrier (arm). 5 The gate must be located at the leading edge,...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 6

... should be installed with top of curb if one or two extra for loop sensor leads. UNIT DIMENSIONS 15-3/4" 3-1/2" 13-1/2" 20-1/4" 41-1/2" 20-1/4" 21-1/2" 41-1/2" 36-1/2" ...24" x 24") Gate Arm Bracket 7-1/8" 7-1/8" 3-1/2" 42" 10-1/4" 42" 36-1/2" 9-7/8" 8-1/4" Open Area In Base For Conduit 13-1/2" 14-1/4" 13-1/2" Side View 12-1/4" Door 14-1/4" Tower Foot Print of arm). I N S TA ...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 7

...MEGA ARM. SAMS with maintained contact. visible and clearly labeled. • Disconnecting power at the close input, the CAUTION: DO NOT CONNECT ANY DEVICE WHICH WOULD gate WILL STOP its function is OFF before arm reaches full open , pulse close loop volt rated and at low voltage terminal recommended that if gate is closing motion...to activate the following inputs: 1, 2, 3 OPEN: ...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 8

... MBAT or 29-NP712 for replacement batteries.) Replace in it must go to terminal 4 of one unit to be the master. SET switches on S2, 1-8 the same on , relay will pulse relay when arm reaches full open . Obstruction Signal Connections Terminal 1 of Master must go to terminal 4 of Second and terminal 1 of each...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 9

...Blue FIGURE 3 Arm shown in the direction of the arm and is level with mount bracket, note the small limit sensors on (Figure 1), motor wires are totally sure you have the arm, when across.... Cam Arm Output Shaft of the unit or behind the unit when viewed from the traffic flow direction (Figure 1). STEP 1: Before power up to the unit's normal operation. Now run the gate open /close switch...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 10

... time is pushed UP from closed limit, used with buzzers, counters, etc.). On the MEGA ARM the switches 1-5 on equals 1.25 seconds, etc.) CLOSE TIMER - Use safety loops, ...activate during open the gate approximately 15 seconds after the obstruction sensor has reversed and re-opened the arm or if the S2-7 timer to operate as a pulse open time. The default of power. INPUT MEMORY: Activates...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 11

..., or play with remote control transmitters. • Activate gate or door ONLY when it can be used to operate the gate. THERE ARE NO OTHER USER SERVICEABLE PARTS. Operation is factory set at NORMAL position to operate at the top of moving gate or garage door: • ALWAYS keep gate or garage door in NORMAL security mode...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 12

...allow the cam arm magnet operation will reverse to the open and close limit sensor (located on ...arm which can increase the risk of travel , then will stop when an object activates the non-contact sensors. adjustments (IF ARM...opening when obstructed, travel, however if leveling of SEVERE INJURY or DEATH: 1. Note that you have programmed the unit to attach arms...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 13

... section for contact information). Charge voltage for battery replacement. SHEAR PIN REPLACEMENT If gate arm is recommended that support motor to allow 1/4" play. 2. Turn on AC power and... light ones) 5. Battery testing is a 2" pin with the right pin type. Reinstall the arm if required 9. Batteries are better than the small hole size of in accordance with 4 bolts ...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 15

SUGGESTED LOOP SENSOR LOCATIONS FREE EXIT ON VEHICLE APPROACH Gate will open inputs. Terminal #7 is close the gate, use ONLY on a dedicated free exit. When vehicle passes and clears close loop, gate will close (Figure 1). FIGURE 2 Mega Arm Close Loop Mega Arm Card Reader Tele-entry Radio Control DO NOT ALLOW CONTROL DEVICES TO BE WITHIN 10...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 16

... operator. c. WIRE THE CONNECTIONS BETWEEN THE OPERATORS 1. Connect the Normally open output (NO) of the trap unit (J5 - To test, activate the following sequence of the second unit. 2. When the second gate is down . 2. TRAP INSTRUCTIONS INSTALL THE K1 AUXILIARY RELAY AND CONNECTOR AT MEGA ARM CONNECTED TO THE ACCESS DEVICE 1. term#12). 3. SET THE DIP...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 17

... memory) to the MEGA ARM J5#8 and one tripped. NOTE: A separate open signal, it without raising the gate arm. Tampering with the other operator's safety loops, safety edges and reverse sensors WILL NOT cause the arm to raise again if it to store input counts via a car crossing the MEGA ARM's close loop. SAMS TWO MEGA ARMS WITH "MEMORY" REQUIRES...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 18

...opened or closed during service of unit. CONTROL BOARD LAYOUT Open Limit Sensor Open Drivers On Motor Brake On Close Drivers On Close Limit Sensor Obstruction Sense (IRD and MRT) Relay Indicator Relay (Optional) Open... OF FUSE D26 D25 - D12: Battery status. Reader, Push Button Aux Open / Reset (Pulse Open/Close) Safety Loop Input Close Gate Input - D14: AC power indicator. Shows...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 19

... Suppressor Collar Nylon Washer PARTS SHIPPED ITEM MEGA ARM Operator Controller Unit Cover Installation and Service Manual Arm Bolts with Washers Nylon Nuts 7AH Batteries MEGA ARM TOWER UNIQUE PARTS LIST QTY ITEM PART NUMBER DESCRIPTION 1 * MA020T Unit Cover for Mega Arm Tower 1 * MA020D Unit Door for Mega Arm Tower 1 1 MEGA ARM OPTIONS PARTS LIST 2 ITEM PART NUMBER DESCRIPTION...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 20

...12' x 3" diameter with warning labels. 373LM SECURITY✚® 3-Button Remote Control: Includes visor clip. CPT43 A24 PassportTM 4-Button Remote Control: Includes visor clip. 24Vdc Loop Detector MA028 MA029 MA030 MA117 Round Padded Arm: 14' x 4" diameter, yellow (requires MA031). Slip Clutch Option: For Mega Arm Gear Box. MA116 MA116R MA034 (Highly Recommended) MA033 MA035 MA024...
MATDCBB Green Control Board V.6.4 or newer Manual - Page 23

... ALLOW CHILDREN TO PLAY NEAR OR OPERATE AUTOMATIC GATES. IN ORDER TO INSTALL AND USE THE MEGA ARM, YOU MUST UNDERSTAND AND BE IN FULL UNCONDITIONAL AGREEMENT WITH ALL STIPULATIONS OUTLINED ABOVE. Materials,...! YOU MUST PROVIDE APPROPRIATE SIGNAGE BEFORE ACTIVATING THE UNIT. The warranty will be suitable for a particular purpose. MEGA ARM NOT FOR USE WITH BICYCLES OR PEDESTRIANS.

Similar Questions

I Have Installed A Chamberlan Garage Door Opener And The Remote I Was Using Is
I have been using a Chamberlan garage door opener and its remote has been defective since of late.Pl...
(Posted by donweera42 8 months ago)
Garage Door Opens After Shutting.
My Lift master 8550 inside keypad is Inside wall pad is model #880LM. outside keypad Model # is 877M...
(Posted by BONNIECA92 2 years ago)
Remote Control For Liftmaster /chamberlain 3850 Garage Door Opener
what is the correct remote control for the chamberlain/liftmaster 3850 garage door opener
(Posted by sendtoalice 9 years ago)
Exit Gate Arm On Mega Arm System Stays Up. The Back Light Is On & Will Not Clea
The exit arm would only operate part of the time and could be made to go down by simply pushing on t...
(Posted by batch40 10 years ago)
Installing Loop Detector On Control Board Of Liftmaster
Model: MAT-DC-BB3 Serienr: 0911N8156 Mega Arm Tower We are having problems with installing our ne...
(Posted by maintenance38060 11 years ago)
Ask a New Question
Use the box below to post a new question about this LiftMaster product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

LiftMaster Manuals

Find free LiftMaster MEGA ARM / MEGA ARM TOWER manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

LiftMaster Reviews

View thousands of LiftMaster user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete LiftMaster customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed LiftMaster customer service rankings, employee comments and much more from our sister site.