Get support for Sharp CV10NH - 10,000 BTU Portable Air Conditioner

Sharp CV10NH Support Question

Sharp CV10NH Support Question

Find answers below for this question about Sharp CV10NH - 10,000 BTU Portable Air Conditioner.
Need a Sharp CV10NH manual? We have 1 online manual for this item!
Question posted by yemFANTO on October 29th, 2013

Sharp Cv-10nh Portable Air Conditioner How To Remove Front

The person who posted this question about this Sharp product did not include a detailed explanation. Please use the "Request More Information" button to the right if more details would help you to answer this question.

Current Answers

There are currently no answers that have been posted for this question.
Be the first to post an answer!

Remember that you can earn up to 1,100 points for every answer you submit. The better the quality of your answer, the better chance it has to be accepted.

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

...WARRANTY E-3 • PRECAUTIONS E-4 • LOCATION E-7 • INCLUDED E-7 • PART NAMES E-8 • INSTALL WINDOW PANEL E-10 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-14 • PRE-OPERATION CHECKS E-16 • COOL MODE E-18 • DEHUMIDIFICATION MODE E-19 • ...product. ENGLISH ENGLISH This manual explains the proper use of your new air conditioner.
CV-10NH Operation Manual - Page 4

... Authorized Servicer) PARTS (for your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 TO ACCESS THE INTERNET: www.sharpusa.com Please provide the following information when ...
CV-10NH Operation Manual - Page 5

...CV-10NH Portable Air Conditioner. Correction of defects, in addition to whatever implied warranties may be granted to the purchaser for parts or labor for the Sealed Cooling System parts; One (1) year parts and labor from date of Sharp... of Purchase available. The limited warranty described herein is necessary to remove the Product, the Servicer will reinstall it will be liable or ...
CV-10NH Operation Manual - Page 6

... appropriate wall socket. Replacement must be performed by one or more as shown on the right. WARNING FOR POWER SUPPLY CORD • This air conditioner uses a plug with the air conditioner (ex. E-4 Only use a three-pin grounded electrical AC socket rated 125V, 60Hz, and 15 amps or more of a power supply with an improper...
CV-10NH Operation Manual - Page 7

...spill out while being moved. • Remove the window panel in the event of ...remove the round grounding pin from this plug. ent level during use of the grounding plug can cause electrical shock or equipment damage. • Drainage should be below freezing point when used , make sure the electrical box is fully grounded. E-5 The plug must not be performed whenever moving the air conditioner...
CV-10NH Operation Manual - Page 8

... be blown out from freezing. • Dehumidification mode increases room temperature. If you restart the air conditioner within the unit. (See page 26) OPERATING CONDITIONS • The air conditioner must remove the heat produced by the unit outside through any openings into the room. • When cooling operation is full, the unit stops...
CV-10NH Operation Manual - Page 9

...placed within reach of a properly rated grounded socket. • Never place any obstacles around the air inlet or outlet of space from the wall for direct installation.) E-7 MIN.12" (30cm) INCLUDED...needs to aid placement, but it should be placed on carpet surfaces. ENGLISH LOCATION • The air conditioner should only be rolled on smooth, flat least 12" (30cm) of the unit. ...
CV-10NH Operation Manual - Page 10

... signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power supply...
CV-10NH Operation Manual - Page 12

...in the insect guard net. net Side "A" will be unable to shut the exhaust cover. (1) Remove the adjustment panel from the window panel, and cut the window panel to the insect guard net..... Foam seal A (adhesive type) 4 Attach the window panel to the window stool. E-10 Cut Window panel Window stool INSTALL WINDOW PANEL Installation in a double-hung sash window (See page 12...
CV-10NH Operation Manual - Page 14

...into the holes in the diagram. INSTALL WINDOW PANEL Installation in a sliding sash window (See page 10 for installation in the insect guard net. If the inner height of the window is installed in ...less than 22" (559mm) high, as you will be unable to shut the exhaust cover. (1) Remove the adjustment panel from the window panel, and cut the window panel to the same height as ...
CV-10NH Operation Manual - Page 16

... the exhaust hose adapter into the window exhaust adapter, and turn it must be installed or removed in a double-hung sash window. Extend one end of window exhaust adapter marked "TOP" ... times) until it is installed in accordance with container(minimum capacity 31/2 gallons) Remove Installation of window exhaust adapter marked "TOP" should be as short as possible for operational ...
CV-10NH Operation Manual - Page 17

... by pushing down two "PUSH" markings, and slide and close the exhaust cover in the window panel. 2 Remove the exhaust hose adapter from the unit by pushing down on the two projections. ENGLISH Removal of the exhaust hose 1 Remove the window exhaust adapter. Lift up and remove the exhaust hose adapter from the unit.
CV-10NH Operation Manual - Page 18

... NOTES: • The battery should last approximately one year under normal use the air conditioner if the above procedure cannot be using the unit for a prolonged period, remove the batteries from the remote control. PRE-OPERATION CHECKS POWER PLUG CHECK This air conditioner uses a fused power plug. Always check the power plug before use . Disconnect...
CV-10NH Operation Manual - Page 19

... to direct sunlight or near a heater. evisions, VCRs or other remote controllers for tel- To prevent the remote control from being misplaced, hook it to remove the remote control from moisture and shock which can discolor or damage it out. A beep will sound when the unit receives the signal. • Make...
CV-10NH Operation Manual - Page 21

..., do not bend the hose at a time. CAUTION When operating dehumidification with container 1 Remove the exhaust hose (See Page 15) 2 Turn the drainage nozzle to the OPEN position. 3 Pull...than when operating dehumidification with the unit turned off . In this mode, the air conditioner dehumidifies the room. Do not operate in dehumidify mode for easier drainage. Drain ...
CV-10NH Operation Manual - Page 22

...FAN button to set the desired fan speed. • Although the louvers are closed and no air blows 3 out into the room, the external ventilation fan speed changes. QUIET LOW HIGH TO TURN...20 VENTILATION MODE In this mode, the air conditioner simply circulates the air without cooling it. FAN MODE In this mode, the air conditioner ventilates the air to outdoors. Ensure that the stopcock is...
CV-10NH Operation Manual - Page 23

... COOL or DEHUMIDIFI- Condensation may result. NOTE • During VENTILATION mode, UP/DOWN air flow direction cannot be set to malfunction when the remote control is used for ...8226; When the horizontal louvers are positioned at the lowest position in the diagram and adjust the air flow direction. E-21 CATION mode for an extended period of time, condensation may form ...
CV-10NH Operation Manual - Page 24

...; The orange TIMER lamp on the unit will light. • The unit will stop operating after one hour. MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set condition. • If you wish to protect the unit. Alternatively, turn the unit off by pressing the POWER button...
CV-10NH Operation Manual - Page 29

...CLEANING THE INSECT GUARD NET The cooling performance may result in poor cooling performance. Periodically remove the window exhaust adapter from the wall socket before reinstalling them with a soft, dry ... Never operate the unit without the filter. Insect guard net MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Perform drainage to thoroughy dry inside the unit. 3 Clean the filters...
CV-10NH Operation Manual - Page 30

...The exhaust hose must be drained. (See page26) • Check the power plug. (See page16) AIR CONDITIONER DOES NOT COOL PROPERLY • Is it set properly? • Is the window exposed to direct sunlight...calling for about 5 minutes. • Are the OPERATION, TIMER and MEGA COOL lamps blinking? AIR CONDITIONER DOES NOT OPERATE AT ALL • Is the unit plugged in FAN mode with the fan speed...

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.