Get support for Sharp CV10NH - 10,000 BTU Portable Air Conditioner

Sharp CV10NH Support Question

Sharp CV10NH Support Question

Find answers below for this question about Sharp CV10NH - 10,000 BTU Portable Air Conditioner.
Need a Sharp CV10NH manual? We have 1 online manual for this item!
Question posted by Rodriguez212076 on June 28th, 2016

Why Is My Sharp Portable A.c Lights Blinking After On For 10 Minutes?

How to connect how's to portable sharp A.C?

Current Answers

Answer #1: Posted by waelsaidani1 on June 29th, 2016 10:04 AM
This answer was accepted by the poster of the original question.
waelsaidani1

Member since:
May 12th, 2013

Points: 19,501,787
1,090
points
If the unit stops operating and the TIMER, OPERATION and MEGA COOL lamps are blinking. (This indicates that the water tank inside the unit is full.)

Related Sharp CV10NH Manual Pages

CV-10NH Operation Manual - Page 3

...E-3 • PRECAUTIONS E-4 • LOCATION E-7 • INCLUDED E-7 • PART NAMES E-8 • INSTALL WINDOW PANEL E-10 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-14 • PRE-OPERATION CHECKS E-16 • COOL MODE E-18 •... This manual explains the proper use of your new air conditioner. This manual should be kept in a safe place for handy reference.
CV-10NH Operation Manual - Page 4

... mailing address (including zip code), your Authorized Parts Distributor) ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE: For service problems, warranty information, missing items and other assistance: Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville, IL 60446-1091 TO ACCESS THE INTERNET: www.sharpusa.com Please provide the following information when...
CV-10NH Operation Manual - Page 5

... and service are not provided free of purchase for this Product: Additional Item(s) Excluded From Warranty Coverage (If any printed materials. USERS SHARP ELECTRONICS CORPORATION warrants to Obtain Service: CV-10NH Portable Air Conditioner. Be sure to the Product, and shall constitute full satisfaction of the Product, filters, or accessories, or any ): Where to Obtain Service...
CV-10NH Operation Manual - Page 6

..., under any part of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the room air conditioner and radio/TV receiver. • Connect the room air conditioner into an appropriate wall socket. Read the precautions on a circuit different from the product manufacturer and not repaired. WARNINGS FOR USE •...
CV-10NH Operation Manual - Page 7

... the tank, it may be plugged into a socket that has a grounding wire connected to a grounding plug. Extremely adverse weather may cause water to leak in any ... proper drainage, the drainage hose must not be on a differ- The plug must be performed whenever moving the air conditioner. (See Page 26) If any maintenance or cleaning. • Do not splash or pour water directly onto ...
CV-10NH Operation Manual - Page 8

...COOL lamps will blink. Setting the unit to freeze. When water tank inside the unit may cause the unit to a higher temperature will be operated within three minutes, a protective...? E-6 If you turn the air conditioner off unnecessary lights. Warm air will prevent it , allow 3 minutes before restarting the unit. If the power was off for three minutes for safety. • In...
CV-10NH Operation Manual - Page 9

... direct installation.) E-7 Do not attempt to be cut down in size because the window is too narrow for efficient air-conditioning. Screwdriver(medium size Phillips) 2. ENGLISH LOCATION • The air conditioner should only be rolled on smooth, flat least 12" (30cm) of the unit. • Allow at surfaces. Use caution...
CV-10NH Operation Manual - Page 10

... signal receiver 4 window 5 5 POWER Button 6 6 OPERATION Lamp (red) 7 7 TIMER Lamp (orange) 8 9 8 MEGA COOL Lamp (green) 9 9 Air inlet 9 REAR VIEW 0 0 Exhaust air outlet q q Window exhaust adapter w w Exhaust hose e e Remote control hook r t r Air filters y t Drainage nozzle and stopcock y Power supply cord hooks u Drainpipe nozzle and stopcock u i Power supply...
CV-10NH Operation Manual - Page 12

...window panel on each rain Insect guard guard into the holes in a sliding sash window. ) 1 Connect the rain guards to ensure that its four projections fit into the holes in windows less than ... the inner width of the window is between 22" (559mm) and 24" (609mm) inclusive. E-10 Cut Window panel Window stool Foam seal A (adhesive type) 4 Attach the window panel to the ...
CV-10NH Operation Manual - Page 14

INSTALL WINDOW PANEL Installation in a sliding sash window (See page 10 for installation in a double-hung window.) 1 Connect the rain guards to ensure that its four projections fit into the holes in the window panel. Push the insect guard net firmly to ...
CV-10NH Operation Manual - Page 20

... with the stopcock. E-18 AUTO QUIET LOW HIGH TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will light. 3 3 Press the TEMPERATURE button to set the desired temperature. • The temperature can be set within the range of 64°F to 86°F. 1 4 4 Press...
CV-10NH Operation Manual - Page 21

...that the nozzle has not been damaged. In this mode, the air conditioner dehumidifies the room. DEHUMIDIFICATION MODE ENGLISH In this case,... out if attempted during dehumidification mode and the room temperature will light. • The temperature cannot be set. • The fan speed ...blink. In this procedure with the stopcock. Ensure that the stopcock is started.
CV-10NH Operation Manual - Page 22

...light. • The temperature cannot be set. 1 3 Press the FAN button to set the desired fan speed. • Although the louvers are closed and no air blows 3 out into the room, the external ventilation fan speed changes. VENTILATION MODE In this mode, the air conditioner simply circulates the air... mode. E-20 FAN MODE In this mode, the air conditioner ventilates the air to outdoors.
CV-10NH Operation Manual - Page 24

...COOL operation is also cancelled when the mode is changed, or when the unit is set, the unit will light. NOTES: • You cannot set the temperature or fan speed during cooling mode. • The remote ...MEGA COOL OPERATION In this operation, the air conditioner fan works at the formerly set condition. • If you wish to operate the unit for 30 minutes in MEGA COOL mode. • The ...
CV-10NH Operation Manual - Page 25

...set in half-hour (30-minute) increments and from a minimum of half an hour (30 minutes) to 12 hours, in the... display for 5 seconds and then return to the time display. • If you set from 10 to a maximum of 12 hours. Up to 9.5 hours, you can be set the unit to your setting. ENGLISH TIMER OPERATION ON TIMER The unit will turn on the unit will light...
CV-10NH Operation Manual - Page 26

... down to speed through the settings. • The orange TIMER lamp on the unit will light. 1 • The unit will emit a beep when it receives the signal. •...even after the power is restored. Up to 9.5 hours, you can be set from 10 to turn off 2.5 hours later. NOTES ON TIMER SETTING AND OPERATION • The ...in half-hour (30-minutes) increments and from a minimum of half an hour (30...
CV-10NH Operation Manual - Page 27

... 68˚F. TO TURN OFF NOTES: Press the POWER button again. • The red OPERATION lamp on the unit will 1 light. • If the unit has not been unplugged since it was last operated, it will resume operation at its last settings. ... off. • Upon starting MAIN UNIT operation, the drainage pump inside the unit runs for about a minute, which may produce an audible gurgling sound.
CV-10NH Operation Manual - Page 28

... water will light. 3 When drainage water stops running out from the hose, turn the unit off by pressing POWER button. Hose band • This will take about one minute. 4 Remove...the drainage nozzle. • When the stopcock is removed, a small amount of water that may be blinking. 7 When drainage water stops running out from the drainage nozzle. 4 Attach the drain grommet to a...
CV-10NH Operation Manual - Page 30

...or off, and also during cooling operation within 3 minutes of the refrigerant flowing inside the unit. • This air conditioner evaporates water condensed during operation. TIMER DOES NOT WORK...malfunctioning, check the following points before calling for about 5 minutes. • Are the OPERATION, TIMER and MEGA COOL lamps blinking? If the power was off , preventing cooling for the...
CV-10NH Operation Manual - Page 60

TH 1 ESPAÑOL SHARP ELECTRONICS CORPORATION Sharp Plaza, Mahwah, New Jersey 07430-2135 U.S.A SHARP CORPORATION S-31 Printed in Thailand TINSEA541JBRZ 07M-

Similar Questions

Ask a New Question
Use the box below to post a new question about this Sharp product .
Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Sharp Manuals

Find free Sharp CV10NH - 10,000 BTU Portable Air Conditioner manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Sharp Reviews

View thousands of Sharp user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Sharp customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Sharp customer service rankings, employee comments and much more from our sister site.