43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 1
43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields
Revision: 11/13
Copyright © 1994-2013 Campbell Scientific, Inc.
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 3
...warranties, expressed or implied. This warranty is in materials and workmanship under this warranty is part of America. The customer shall assume all other locations, Campbell will return such products by Campbell Scientific, Inc. ("Campbell") to repairing or replacing (at Campbell's option) defective products, which have no warranty. Products not manufactured, but that are re-sold...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 4
... application engineer determines the nature of the problem, an RMA number will be either emailed to repair@campbellsci.com or faxed to (435)...service on the outside of the shipping container. If the form is not received within their territories. Affiliate companies handle repairs for our employees. The form is available from our web site at the customer's expense. Campbell Scientific...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 7
... for the 43347 and 43502 is specified when the probe/shield is ordered.
The 43347 is included with an uncertainty of the data to reduce radiation errors. The blower... the model 43347 RTD Temperature Probe (43347-L), and the 43502 Aspirated Radiation Shield (43502-L) indicates that is a 1000 ohm Resistance Temperature Device (RTD) used with :
(1) Instruction Manual
1 The 43347 probe ...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 8
43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields
2. Specifications
43502 ASPIRATED RADIATION SHIELD
Sensor Types:
Accommodates sensors up to 24 mm (0.9 in) diameter
Radiation Error:
Ambient Temp:
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 9
...to the other set of any ...Installation
±0.3°C at 0° C ±0.1°C with datalogger • small Phillips screw driver...installation and cable connections. The surface should be covered by short grass, or where grass does not grow, the natural earth surface. The CM204 crossarm includes the CM210 Mounting Kit for a secure hold without distorting the plastic v-block. 43347...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 11
... on the bottom plate of holes to attach the shield it to a crossarm. 43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields 43502 Shield
CM200-series Crossarm
FIGURE 3-2. 43502 Radiation Shield mounted to a CM200-series Crossarm
3.4 41003-5 Radiation Shield Installation
The 41003-5 Radiation Shield has a U-bolt for attaching the shield to the...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 13
... 4-1. The "IX" version connects to the CR3000 or CR5000 dataloggers as described in Section 6, 43347-IX Measurement using Current Excitation.
4.1 43347-VX Temperature Probe Wiring
The 43347-VX probe is used to create the datalogger program, wire the sensor to Campbell Scientific dataloggers are wired to dataloggers that only have voltage excitation (e.g., CR10(X), CR800, CR1000...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 14
43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields
NOTE
TABLE 4-1. Datalogger Connections...this by using a 4WPB1K terminal input module (refer to Datalogger
Datalogger Connections: White - Ground
User-Provided Cable to the 4WPB1K manual for shield connections.)
Transformer Connections: Red - 12V Black - RTD Orange RTD Signal Ref Purple Excitation Reference Clear Shield G
...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 15
...an excitation voltage and makes two differential voltage measurements. The program examples include instructions to use Short Cut. Storing the output frequency is a way to measure ... 4-wire half bridge measurement using Campbell Scientific's Short Cut Program Builder software. The 43347 temperature is made across the RTD (Rs).
Datalogger Programming for the 43347-VX Probe
This section is for...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 18
... accordance with DIN Standard 43760. The RTD temperature instruction converts Rs/Ro to Rs/Ro (assuming Rf and Ro both equal 1000 ohms). 43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields
7: 1 8: 1 9: 0
Loc [ RTD_C ] Mult Offset
;Apply calibration coefficients (probe specific) ;43347 Calibration T = -250.052585,+(R*2.375187e-1)+(R^2*1.258482e-5)
2: Polynomial (P55)
1: 1
Reps...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 19
...3: Pulse (P3) 1: 1 2: 6 3: 20 4: 2 5: 1.0 6: 0.0
Reps Control Port 6 High Frequency, Output Hz Loc [ Tach_Hz ] Multiplier Offset
6. 43347-IX Measurement using Current Excitation
The 43347-IX probe is measured with the Resistance measurement instruction with the CR3000 and CR5000 dataloggers. 43347 RTD Temperature Probe, 43502 and 41003-5 Radiation Shields
5.2.2 CR10X Example for Uncalibrated...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 20
...manual for users who write their own programs. A datalogger program to measure this sensor can be created using Campbell Scientifics' Short Cut Program Builder software. The customer can do not need to connect an "IX" version of the sensor to a datalogger that has voltage excitation only (e.g., CR10(X), CR800, CR1000). 43347...Return/- RTD
FIGURE 6-1. 43347-IX Temperature Probe schematic
...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 25
...(higher) contiguous channel. The white and green wires connect to the RM Young 43502 Instruction Manual for Instruction 16. For uncalibrated temperature probes (Section 6.2, Datalogger Programming), make sure the coefficients have been properly entered for additional information such as replacement parts, assembly drawings, and electrical schematics.
10. Also, check that the black and orange...
43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield - Page 33
... tee at least 24 inches.
PN 7515 10 m Aspirated Shield Mounting Bracket
C-3 Appendix C. 43347 Aspirated Radiation Shield
C.2 Installation
Refer to the General Assembly drawing in the RM Young 43408 Instruction Manual (included) for a secure hold without distorting the plastic v-blocks. Campbell Scientific pn 7515 10 m Aspirated Shield Mounting Bracket can be horizontal with the vent...