Fluke 374, 375, 376 Users Manual - Page 1

All rights reserved. All product names are subject to change without notice. Specifications are trademarks of their respective companies. 374/375/376 Clamp Meter Users Manual PN 3608883 July 2010 © 2010 Fluke Corporation. Printed in China.
Fluke 374, 375, 376 Users Manual - Page 2

... to that Service Center with a description of liability may not apply to extend any other warranty on Fluke's behalf. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of the problem. The Netherlands 11/99 Fluke Corporation Fluke Europe B.V. P.O. Box...
Fluke 374, 375, 376 Users Manual - Page 4

374, 375, 376 Users Manual ii
Fluke 374, 375, 376 Users Manual - Page 5

... Flexible Current Probe provides increased display flexibility and allows measurements of awkward sized conductors and improved wire access. The illustrations in this manual show the 376. 1 The Fluke 374, 375, and 376 (the Meter) measure true-rms ac current and voltage, dc current and voltage, inrush current, resistance, and capacitance. The detachable iFlex (Flexible...
Fluke 374, 375, 376 Users Manual - Page 6

..., or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 2 To register your product, visit http://register.fluke.com. 374, 375, 376 Users Manual How to Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) •...
Fluke 374, 375, 376 Users Manual - Page 7

... procedures that pose hazard(s) to the user. Look for damaged insulation or exposed metal. Replace damaged test leads before the battery door is opened. • Examine the test leads ..., have the Meter serviced. 3 XWWarning To prevent possible electrical shock or personal injury, follow these guidelines: • Use the Meter only as specified in this manual are inserted into the...
Fluke 374, 375, 376 Users Manual - Page 8

...disconnect the live test lead. 374, 375, 376 Users Manual • Do not use only specified replacement parts. • Have the Meter serviced only by qualified service personnel. • Be careful around bare ... • When servicing the Meter, use the Meter around explosive gas, vapor or in damp or wet environments. • Use only type AA batteries, properly installed in an emergency....
Fluke 374, 375, 376 Users Manual - Page 10

... test: • Use the proper jacks, function, and range for recycling information. Do not use abrasives or solvents. 374, 375, 376 Users Manual WCaution To avoid possible damage to the Meter or to Fluke's website for the measurement application. • Clean the case and accessories with a damp cloth and mild detergent only. X Hazardous...
Fluke 374, 375, 376 Users Manual - Page 11

Examined and licensed by TÜV Product Services. - Double insulated Conforms to or remove from HAZARDOUS LIVE conductors is permitted. 7 Clamp Meters Safety Information Symbol Meaning W  ® Risk of Danger. See Manual. Battery. Low battery when shown on display. Do not apply to relevant Australian standards. Symbol ) T ; , Meaning Conforms to relevant North ...
Fluke 374, 375, 376 Users Manual - Page 12

... in fixed-equipment installations, such as an electricity Meter or an overhead or underground utility service. Note The Measurement Category (CAT) and voltage rating of any combination of test probe, test probe accessory, current clamp accessory, and the Meter is the LOWEST rating of any individual component. 8 374, 375, 376 Users Manual Symbol Meaning...
Fluke 374, 375, 376 Users Manual - Page 16

374, 375, 376 Users Manual Flexible Current Probe 1 2 0.5 A 12 3 fig06.eps
Fluke 374, 375, 376 Users Manual - Page 18

374, 375, 376 Users Manual 3 1
Fluke 374, 375, 376 Users Manual - Page 20

374, 375, 376 Users Manual e e 16 R ON
Fluke 374, 375, 376 Users Manual - Page 24

374, 375, 376 Users Manual AC Current via Flexible Current Probe Range 2500 A Resolution 374 and 375 0.1 A (≤ 600 A) 1 A (≤ 2500 A) 376 0.1 A (≤ 999.9 A) 1 A (≤ 2500 A) Accuracy 3 % ±5 digits (5 - 500 Hz) Crest Factor (50/60Hz 3.0 at 1100 A (375 and 376 only) 2.5 at 1400 A 1.42 at 2500 A Add 2 % for C.F. > 2 20
Fluke 374, 375, 376 Users Manual - Page 26

374, 375, 376 Users Manual Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ± 0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ± 1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ± 2.0 % Measurement uncertainty assumes centralized ...

Fluke 376 FC-NIST Reviews

Do you have an experience with the Fluke 376 FC-NIST that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Ask a New Question
Use the box below to post a new question about Fluke 376 FC-NIST.
Manuals / Documents
Download any of our Fluke 376 FC-NIST manuals for free!

We have the following 1 documents available for the Fluke 376 FC-NIST:
  • Fluke 374, 375, 376 Users Manual

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 376 FC-NIST manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 376 FC-NIST user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.