CS11-L Current Transformer - Page 1
CS11-L Current Transformer
12/13
Copyright © 2001-2013 Campbell Scientific, Inc.
CS11-L Current Transformer - Page 3
... this warranty is in the corresponding Campbell pricelist or product manual. Campbell will return such products best way CIP (Port of America. Campbell is not liable for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by Campbell Scientific, Inc. ("Campbell") to any special, indirect, incidental...
CS11-L Current Transformer - Page 4
... unable to contaminants that were exposed to process any returns until we receive this form. Campbell Scientific reserves the right to refuse service on the outside of product receipt or is :
CAMPBELL SCIENTIFIC, INC. Affiliate companies handle repairs for customers within three days of the shipping container. If the form is not received within their territories...
CS11-L Current Transformer - Page 7
...models past and present, including the CR200(X). Specifications
Example Applications: • Motor or generator load conditions • Efficiency studies • Intermittent fault detection • Submetering
1 The CS11-L does not have direct electrical connection to 125 amps. The CS11... to 200 A. General Description
Campbell Scientific's CS11-L (FIGURE 1-1) detects and measures...
CS11-L Current Transformer - Page 12
FIGURE 5-2.
See FIGURE 5-2. ACPower Configuration 2 6 CS11-L Current Transformer
Option 2
Description
Split-phase with one voltage measurement and two current measurements. Split-phase configurations have two line (or "hot") conductors plus a neutral conductor. This configuration is typical of residential service-entry panels, as well as residential and commercial distribution panels.
CS11-L Current Transformer - Page 16
...SCWin users: This manual was written primarily for each of the three line conductors.
The cosine of SCWin. VHarmRatio is the power factor. In CRBasic, the VoltSE instruction is used to...many samples from the CS11-L sensor to do this, depending on the range code.
10 CS11-L Current Transformer
Current(3). Your procedure is much simpler: just add the CS11-L (in the ...
CS11-L Current Transformer - Page 18
...) is to the rms value;
The recommended programming method for the CS11-L (200Amps/1000mV=0.2)
Scan (500,mSec,0,0)
Battery (Batt_volt)
ACPower (Array1(),1,60,1,0.345345,120,2,.2,200,1)
CallTable (AmpTable)
NextScan
EndProg
6.2 CR200X-series Dataloggers
The CS11-L is applied to place the VoltSE instruction within a loop. In the program, a multiplier of 0.2 is compatible with the...
CS11-L Current Transformer - Page 19
...
6.2.1 CR200(X) Program for 60 Hz
'CR200 Series Datalogger ' Program name: CS11-LManual60Hz.cr2 'date: Jun 2013
Const Samples = 25 'Const Samples = 30 Public Crnt_A Public mV(Samples) Dim Counter
' 25 samples for 2 waves of 0.2 is calculated using the RMSSpa instruction. CS11-L Current Transformer
samples 25 times, and the second CR200X example program has...
CS11-L Current Transformer - Page 20
..., the entry for parameter 4 needs to make millivolt burst measurements using Instruction 23 and then calculate rms using Instruction 82. The multiplier for the CS11-L is important to measure complete cycles. For Instruction 23, if parameters 5 and 6 are 2.0 and 0.05, respectively, you get five complete cycles for a 50 Hz waveform, and six complete cycles...
CS11-L Current Transformer - Page 21
... 5 & 6 are required to program this part of the code works mathematically the same ; Change according to expected Amperage
3: 1
In Chan
; Must be 2500 mV for 0-4.9 amps
; First location of CS11-L waveform using burst mode
The following CR10X program... 2.0 msec = 100 mS)
7: 0
Samples before Trigger
;
The instructions listed below do not store data in thousands)
;
CS11-L Current Transformer - Page 23
... (P89)
1: 4
X Loc [ Counter ]
2: 1
=
3: 90
F
4: 10
Set Output Flag High
8: Z=X (P31)
1: 57
-- CS11-L Current Transformer
NOTE
The instructions listed below do not store data in final storage. Use F4 to store the data permanently.... periods. However, if the datalogger's Burst Measurement Instruction is used with specific settings, the program will make more than two measurements ...
CS11-L Current Transformer - Page 25
This part of the code works mathematically the same ; The rms ; Clock multiplexer to next channel
4: Do (P86) 1: ...and stored back into an input location for CS11-L
;
; and AM1632 Multiplexer.
;
*Table 1 Program
01: 30
Execution Interval (seconds)
; value is easier to test the CS11-L sensor on the multiplexer
1: Do (P86) 1: 41
Set Port 1 High
2: Excitation with Delay (P22...
CS11-L Current Transformer - Page 26
...Set Active Storage Area (P80)^17815
1: 1
Final Storage Area 1
2: 60
Array ID
16: Real Time (P77)^10331
1: 1220
Year,Day,Hour/Minute (midnight = 2400)
17: Average (P71)^5143
1: 64
Reps
2: 4
Loc [ CS11_1 ]
*Table 2 Program
02: 0.0000
Execution Interval (seconds)
*Table 3 Subroutines
;
; This part... 0.05 thousand scans for 0-4.9 amps
; CS11-L Current Transformer
10: Do (P86) 1:...
CS11-L Current Transformer - Page 27
... 1
Z Loc [ Counter ]
9: If (XF) (P89)
1: 1
X Loc [ Counter ]
2: 1
=
3: 50
F
4: 10
Set Output Flag High (Flag 0)
10: Set Active Storage Area (P80)
1: 3
Input Storage Area
2: 2
Loc [ BurstAmps ]
11: Standard Deviation (P82)^13110
1: 1
Reps
2: 71
... 00
n, Exponent of 10
3: 1
Z Loc [ Counter ]
7: Beginning of Subroutine (P85)
1: 3
Subroutine 3
CS11-L Current Transformer
21
CS11-L Current Transformer - Page 28
...(P95)
22: End (P95)
End Program
22 CS11-L Current Transformer
15: Z=F x 10^n (P30)
1: 0.0
F
2: 00
n, Exponent of 10
3: 1
Z Loc [ Counter ]
16: Beginning of Loop (P87)
1: 0
Delay
2: 50
Loop Count
17: Z=Z+1 (P32)
1: 1
Z Loc [ Counter ]
18: If (XF) (P89)
1: 1
X Loc [ Counter ]
2: 1
=
3: 50
F
4: 10
Set Output Flag High (Flag 0)
19: Set Active Storage Area (P80)
1: 3
Input...