Popular Campbell Scientific CS210 Manual Pages
ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures - Page 3
... to modification, misuse, neglect, improper service, accidents of all other locations, Campbell will return such products by Campbell, and product specific training, is limited to Campbell. Campbell will return such products best way CIP (Port of removing, reinstalling, and shipping defective products to repairing or replacing (at Campbell's option) defective products, which have...
ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures - Page 4
... Campbell Scientific company serves your country. Campbell Scientific reserves the right to refuse service on the outside of the problem, an RMA number will be returned without prior authorization. directly. Campbell Scientific's shipping address is available from our web site at the customer's expense. Campbell Scientific is incomplete, the product will be either emailed to repair...
ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures - Page 7
.../12 and ENC10/12R have the flexibility to choose their system components, but installation is also applicable to the prewired enclosures. Multiple cables can use . Customers ... manual pertains to our prewired enclosures. General Description
Environmental enclosures protect our dataloggers and peripherals from water and most pollutants. Besides our standard enclosures, Campbell Scientific ...
ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures - Page 26
... solution of the erosion is inexpensive, Campbell Scientific recommends replacing desiccant packets once they become apparent. ...replaced. When to Replace Desiccant
The humidity indicator card or optional CS210 Humidity Sensor indicate when the desiccant needs to be replaced with fresh packets when the upper dot on the indicator begins to the CS210 manual for sensor specifications, installation...
ENC10/12, ENC12/14, ENC14/16, ENC16/18 Enclosures - Page 45
...contain moth balls or crystals should be hazardous. Keeping Insects Out Of the Enclosure
Campbell Scientific has published an application note regarding how to prevent fire ants, wasps, spiders, and other insects... from the application note on the Campbell Scientific website (www.campbellsci.com/app-notes) and is called "Keeping Pests Away from ...
CS210 (10162) Enclosure Humidity Sensor - Page 1
CS210 Enclosure Relative Humidity Sensor
Revision: 10/07
Copyright © 1996-2007 Campbell Scientific, Inc.
CS210 (10162) Enclosure Humidity Sensor - Page 2
... SENSOR is limited to repairing or replacing (at CAMPBELL SCIENTIFIC, INC.'s option) defective products. to determine which have no warranty. This warranty shall not apply to CAMPBELL SCIENTIFIC, INC. products which Campbell Scientific company serves your country. does not accept collect calls. CAMPBELL SCIENTIFIC, INC.'s obligation under normal use and service for special, indirect...
CS210 (10162) Enclosure Humidity Sensor - Page 3
... on a CR1000 2 2. Datalogger Connections 2 2. Wiring for Relative Humidity 3 3. Specifications 1 3. Installation 1 4. Calibration for Examples 3 and 4 5
i Programming 3
5.1 CRBasic Examples 3 5.2 Edlog Examples 5
6. CS210 Table of this document. Enclosure Humidity 7 7. CS210 Wiring 2
Tables
1. General 1 2. Maintenance 7 Figures
1. Use the Adobe Acrobat...
CS210 (10162) Enclosure Humidity Sensor - Page 5
... in.) Probe Cross Section Area: 0.6 cm x 1.1 cm (0.23 in the field. Specifications
Sensor: Elan HM2000 series precision bulk-polymer Relative Humidity Measurement Range: 0 to 100% non...in . x 0.43 in.) Current Consumption: The CS210 was once known as the 10162.
2. CS210 Enclosure Humidity Sensor
1. General
NOTE
The CS210 Enclosure Humidity sensor contains an Elan HM2000 series precision bulk...
CS210 (10162) Enclosure Humidity Sensor - Page 6
TABLE 1. Wiring
Connections to Campbell Scientific dataloggers are given in Table 1 and Figure 2. CS210 Enclosure Humidity Sensor
FIGURE 1. CS210 Installed on a CR1000
4. Datalogger Connections
Description Color Relative Humidity White
CR200-series Single-Ended
CR800, CR850, CR1000, CR3000, CR5000, CR9000(X), CR10(X), CR500, CR510, CR23X
Single-Ended ...
CS210 (10162) Enclosure Humidity Sensor - Page 7
...CS210 approximately 10 seconds for users who write their own datalogger programs. A datalogger program to be created using a single-ended analog measurement (CRBasic instruction SEVolt or Edlog Instruction 1). Depending on .
Notice that the scan rate is measured using Campbell Scientific...first few measurements from the CS210 is set at 10 seconds. Example 2 is a sample CRBasic...
CS210 (10162) Enclosure Humidity Sensor - Page 8
...,0.1,0) 'Set the sensor to 100% if it exceeds 100%. If Enc_RH > 100 Then Enc_RH = 100
CallTable Daily NextScan EndProg
Example 2. Don't need a delay. Sample CR200 Program
'CR200 Series Datalogger 'To create a different opening program template, type in new 'instructions and select Template | Save as Default Template 'date: 'program author:
'SENSOR WIRING 'CS210 'Black...
CS210 (10162) Enclosure Humidity Sensor - Page 9
....
;
01: Volt (SE) (P1)
1: 1
Reps
2: 5
2500 mV Slow Range
3: 6
SE Channel
4: 3
Loc [ RH_enc ]
5: .1
Mult
6: 0
Offset
;CR510 (2500 mV); PortSet (C2,1 ) VoltSe (Enc_RH,1,1,0.1,0) 'Set the sensor to power the CS210. The 21X program turns on control port 1 to 100% if it on.
Wiring for a 21X Micrologger;
The sensor won't give a good reading until...
CS210 (10162) Enclosure Humidity Sensor - Page 10
...
Execution Interval (seconds)
1: Batt Voltage (P10)
1: 1
Loc [ Batt_Volt ]
2: Panel Temperature (P17)
1: 2
Loc [ PnlTempC ]
;Turn the CS210 on and leave it on. ;The CS210 needs approximately 10 seconds to stabilize. First scan will be low.
3: Do (P86) 1: 41
Set Port 1 High
4: Volt (SE) (P1) 1: 1 2: 15 3: 1 4: 3 5: 0.1 6: 0
Reps 5000 mV Fast Range SE Channel Loc [ Enc_RH...
CS210 (10162) Enclosure Humidity Sensor - Page 11
Replace the CS210 probe every three to four hours.
7. Campbell Scientific recommends that all cable entry ports, that desiccant packs be sealed with a new one.
7 If the probe fails, replace...
Maintenance
The CS210 does not have any user serviceable parts nor does it with plumbers putty and that do not use . Enclosure Humidity
Change the enclosure desiccant packs (model number 4905)...