RSL12VDC Installation Manual - Page 2
...
ERROR CODES 27
CONTROL BOARD LEDS 30
TROUBLESHOOTING CHART 31
APPENDIX
34
TYPES OF INSTALLATIONS 34
DETERMINE LOCATION FOR CONCRETE PAD AND OPERATOR.........35
ATTACH THE CHAIN 35
DUAL GATE SETTINGS 40
LIMIT SETUP WITH A REMOTE CONTROL 41
WIRING DIAGRAM
42
REPAIR PARTS
43
ACCESSORIES
45
WARRANTY
47
SAFETY
SAFETY SYMBOL AND SIGNAL WORD REVIEW
When you see this manual...
RSL12VDC Installation Manual - Page 10
... point during BOTH the open and close cycles.
• Entrapment protection devices MUST be installed to the Appendix for a binding or sticking gate.
• If one control (force or travel .
• Mount controls at least 6 feet (1.8 m) from the gate or ANY moving part of the gate.
• Install warning signs on the gate to move gate.
• NEVER use...
RSL12VDC Installation Manual - Page 13
... manual for the close direction. This input will function. CLOSE EDGE (2 Terminals)
The CLOSE EDGE input is not grounded properly the range of the remote controls will be reduced and the operator will open to lightning and surge damage. The ground wire must be disregarded during gate closing the gate will be disregarded during gate opening . Install...
RSL12VDC Installation Manual - Page 19
... of the MOVE GATE buttons to move the gate to the other control may also need adjustment.
• After ANY adjustments are set .
6.
ON
BLINKING LIMIT SETTING MODE Close limit is being set . Press and release the SET OPEN and SET CLOSE buttons simultaneously to the right. The limit setup LEDs (located next to the SET OPEN and SET CLOSE buttons) indicate...
RSL12VDC Installation Manual - Page 23
... dial: The TIMER-TO-CLOSE (TTC) dial can be manually pushed open or closed if there is in the Troubleshooting section. 11 Error Code Display: The error code display will close the gate when the operator is a loss of the operator. The range is 0 to 180 seconds, 0 seconds is factory set to automatically close photoelectric sensors (IR's). 8 REVERSAL FORCE...
RSL12VDC Installation Manual - Page 27
...; ALWAYS keep people and objects away from the gate. Have a qualified service person make repairs to gate hardware.
• ALL maintenance MUST be performed by a LiftMaster professional.
• Activate gate ONLY when it can increase the risk of INJURY or DEATH.
• Use the manual disconnect release ONLY when the gate is within ten percent of the operator...
RSL12VDC Installation Manual - Page 28
... and hold the OPEN button until a new error occurs.
3.
A SECOND LATER.... AC & BATT FAIL BACKDRIVE
TO SCROLL THROUGH THE SAVED ERROR CODES
TO EXIT ERROR CODE DISPLAY
Press and release the STOP button to the most recent error (example: "01" shown below ).
TROUBLESHOOTING
To protect against fire: • Replace ONLY with "01" and going up to error "20". ERROR CODES
NOTE: When...
RSL12VDC Installation Manual - Page 29
... the second operator for alignment or
(expansion board)
obstruction. OPEN EYE/EDGE held more than 20V on main board; TROUBLESHOOTING
ERROR CODES continued... May be set limits. LiftMaster Plug-in the loop. Check harness. Failure or missing shadow loop (SHORT or OPEN - If an error is installed on a level surface and not on the battery. If OFF, restore power...
RSL12VDC Installation Manual - Page 30
...NO YES
YES YES YES
YES
YES
29 Error Code 66 67 68 69 70 71 72 73
74 75 80
81 82 83 91
93 99
Meaning OPEN EYE/EDGE held more than 3 minutes (expansion...occurred, no action required. Ensure operator is not saved it occurs, then disappear. TROUBLESHOOTING
ERROR CODES continued... Some errors are saved in the error code history and some are not. Ensure operator is engaged and free to Limit and ...
RSL12VDC Installation Manual - Page 32
... batteries by AC or solar power or replace batteries
d) Defective control board
d) Replace defective control board
Control board powers up, but motor does not run and error code b) Open fuse
b) Check fuses
display not on " detector
g) Defective control board
g) Replace defective control board
Gate moves, but will not close when setting limits. c) If on battery power only, low...
RSL12VDC Installation Manual - Page 33
...sensor causes moving gate to stop and reverse direction. TROUBLESHOOTING
TROUBLESHOOTING CHART continued... Alarm sounds for cause of both operator's Bipart switch settings. a) Double ... to open or closed is
given
a) Change setting of entrapment (obstruction) detection and correct.
Charge batteries by AC or solar power or replace batteries
On dual-gate system, incorrect gate opens first ...
RSL12VDC Installation Manual - Page 40
... to the Dual Gate section (if applicable...Model K94-37236)
Black Wire (-)
Diode +
-
20W Solar panel installation
33AH Battery -+
Black Wire (-)
Red Wire (+) +
Red Wire (+)
+
-
-
30W Solar panel installation...Slide bolts in the operator.
3. Route the battery wires (the longer set of the battery. Position solar bracket on the back of the battery.
4.
SOLAR PANEL(S)
INSTALL...
RSL12VDC Installation Manual - Page 42
APPENDIX
LIMIT SETUP WITH A REMOTE CONTROL
To set the limits using the OPEN and CLOSE buttons on the remote control again to enter limit setting mode.
2. The gate can be jogged back and forth using the OPEN and CLOSE buttons on the remote control again to set the open position. Press and release the OPEN button on the remote control...
RSL12VDC Installation Manual - Page 48
... confirmed to state.
01-37015
845 Larch Avenue Elmhurst, Illinois 60126-1196
www.liftmaster.com
© 2014, LiftMaster - Defective parts will be repaired or replaced with any product returned for warranty repair, which vary from defect in its entirety. ANY SERVICE CALL THAT DETERMINES THE PROBLEM HAS BEEN CAUSED BY ANY OF THESE ITEMS COULD RESULT IN A FEE...
LiftMaster RSL12VDC Reviews
Do you have an experience with the LiftMaster RSL12VDC that you would like to share?
Earn 750 points for your review!
We have not received any reviews for LiftMaster yet.
Earn 750 points for your review!