TD Operating System Addendum for CR510, CR10X, and CR23X
Page 34
... Rf[X/(1-X)] Reps Loc [:SOIL_M_1 ] Multiplier (Rf) Data Table Seconds into interval Seconds interval Records (0=auto; -=redirect) Average Reps Loc REF_TEMP End Table 1 AD-8-4 AM416 Wiring Diagram For Thermocouple and Soil Moisture Block Measurements EXAMPLE PROGRAM MULTIPLEXING THERMOCOUPLES AND SOIL MOISTURE BLOCK * 1 01: 600 Table 1 Programs Sec. PROCESSING AND PROGRAM CONTROL EXAMPLES FIGURE 8.3-1.
... Rf[X/(1-X)] Reps Loc [:SOIL_M_1 ] Multiplier (Rf) Data Table Seconds into interval Seconds interval Records (0=auto; -=redirect) Average Reps Loc REF_TEMP End Table 1 AD-8-4 AM416 Wiring Diagram For Thermocouple and Soil Moisture Block Measurements EXAMPLE PROGRAM MULTIPLEXING THERMOCOUPLES AND SOIL MOISTURE BLOCK * 1 01: 600 Table 1 Programs Sec. PROCESSING AND PROGRAM CONTROL EXAMPLES FIGURE 8.3-1.
CR10X Specifications
Page 1
..., Campbell Scientific recommends...common mode errors. RESISTANCE MEASUREMENTS MEASUREMENT TYPES: The CR10X provides ratiometric bridge measurements of the switched outputs eliminates dc errors. PERIOD... 50% duty cycle RESOLUTION: 35 ns divided by AM16/32 or AM416 Relay Multiplexers and AM25T Thermocouple Multiplexers. RANGE: ±2.5 V RESOLUTION: 0.67 mV ACCURACY: ±5 mV; ...25° to 64 Hz. e.g., ±0.1% FSR = ±5.0 mV for exciting vibrating wire transducers. Fast single-ended voltage: Fast differential voltage: Slow single-ended voltage: Slow differential ...
..., Campbell Scientific recommends...common mode errors. RESISTANCE MEASUREMENTS MEASUREMENT TYPES: The CR10X provides ratiometric bridge measurements of the switched outputs eliminates dc errors. PERIOD... 50% duty cycle RESOLUTION: 35 ns divided by AM16/32 or AM416 Relay Multiplexers and AM25T Thermocouple Multiplexers. RANGE: ±2.5 V RESOLUTION: 0.67 mV ACCURACY: ±5 mV; ...25° to 64 Hz. e.g., ±0.1% FSR = ±5.0 mV for exciting vibrating wire transducers. Fast single-ended voltage: Fast differential voltage: Slow single-ended voltage: Slow differential ...
CR10X Measurement and Control System
Page 7
... Switch Closures on Control Ports (Rain Gage 8-5 8.6 SDM-AO4 Analog Output Multiplexer to Strip Chart 8-6 8.7 Converting 0-360 Wind Direction Output to Measure the ... CONTROL EXAMPLES 8.1 Computation of 2 Final Storage Areas - OUTPUT PROCESSING INSTRUCTIONS 11-1 12. Geokon's Vibrating Wire Pressure Sensor 7-16 7.17 Paroscientific "T" Series Pressure Transducer 7-20 7.18 4 to Power Sensors 8-22... 9-1 10. PROGRAM CONTROL INSTRUCTIONS 12-1 iii CR10X TABLE OF CONTENTS PROGRAM EXAMPLES 7. MEASUREMENT PROGRAMMING EXAMPLES 7.1 Single-Ended Voltage/Switched 12 V ...
... Switch Closures on Control Ports (Rain Gage 8-5 8.6 SDM-AO4 Analog Output Multiplexer to Strip Chart 8-6 8.7 Converting 0-360 Wind Direction Output to Measure the ... CONTROL EXAMPLES 8.1 Computation of 2 Final Storage Areas - OUTPUT PROCESSING INSTRUCTIONS 11-1 12. Geokon's Vibrating Wire Pressure Sensor 7-16 7.17 Paroscientific "T" Series Pressure Transducer 7-20 7.18 4 to Power Sensors 8-22... 9-1 10. PROGRAM CONTROL INSTRUCTIONS 12-1 iii CR10X TABLE OF CONTENTS PROGRAM EXAMPLES 7. MEASUREMENT PROGRAMMING EXAMPLES 7.1 Single-Ended Voltage/Switched 12 V ...
CR10X Measurement and Control System
Page 35
...;5 mV; ±2.5 mV (0° to -peak1 Min. and 6-wire full bridge, and 2-, 3-, and 4-wire half bridges. Any of the 12 single-ended analog input channels can ...time and conversion to 750 Hz are scanned at low frequencies. RESISTANCE MEASUREMENTS MEASUREMENT TYPES: The CR10X provides ratiometric bridge measurements of FSR plus 1.5 cycles + 2 ms PULSE COUNTERS NUMBER OF ...input filter with data transfer is determined by AM16/32 or AM416 Relay Multiplexers and AM25T Thermocouple Multiplexers. Larger input transitions are valid over short intervals. software selectable as ...
...;5 mV; ±2.5 mV (0° to -peak1 Min. and 6-wire full bridge, and 2-, 3-, and 4-wire half bridges. Any of the 12 single-ended analog input channels can ...time and conversion to 750 Hz are scanned at low frequencies. RESISTANCE MEASUREMENTS MEASUREMENT TYPES: The CR10X provides ratiometric bridge measurements of FSR plus 1.5 cycles + 2 ms PULSE COUNTERS NUMBER OF ...input filter with data transfer is determined by AM16/32 or AM416 Relay Multiplexers and AM25T Thermocouple Multiplexers. Larger input transitions are valid over short intervals. software selectable as ...
CR10X Measurement and Control System
Page 195
... at 2.8 V and the low input is at its correct value. 2. If a differential measurement is used in cases where rapid sampling is outside of wire used on the +2.5 V range would indicate a signal of the multiplexed analog inputs must be encountered when the CR10X is desired (Section 7.2). SECTION 13. CR10X MEASUREMENTS In order to be made : 1.
... at 2.8 V and the low input is at its correct value. 2. If a differential measurement is used in cases where rapid sampling is outside of wire used on the +2.5 V range would indicate a signal of the multiplexed analog inputs must be encountered when the CR10X is desired (Section 7.2). SECTION 13. CR10X MEASUREMENTS In order to be made : 1.
CR10X Measurement and Control System
Page 218
SECTION 14. INSTALLATION AND MAINTENANCE TABLE 14.2-1. Typical Current Drain for Common CR10X Peripherals Peripheral Equipment AM16/32 Multiplexer AM25T Multiplexer AM416 Multiplexer COM100 Cellular Phone COM210 Phone Modem COM300 Voice Synthesizer Modem HDR GOES Satellite Transmitter RAD Modem and SC932 Interface RF300-RF304 Radios RF95(A) RF Modem SAT Argos Satellite Transmitter SDM-AO4 SDM-CD16AC SDM-INT8 SDM-SIO4 SDM-SW8A SM4M/SM16M Storage Module Typical Current Drain (mA) Quiescent Active
SECTION 14. INSTALLATION AND MAINTENANCE TABLE 14.2-1. Typical Current Drain for Common CR10X Peripherals Peripheral Equipment AM16/32 Multiplexer AM25T Multiplexer AM416 Multiplexer COM100 Cellular Phone COM210 Phone Modem COM300 Voice Synthesizer Modem HDR GOES Satellite Transmitter RAD Modem and SC932 Interface RF300-RF304 Radios RF95(A) RF Modem SAT Argos Satellite Transmitter SDM-AO4 SDM-CD16AC SDM-INT8 SDM-SIO4 SDM-SW8A SM4M/SM16M Storage Module Typical Current Drain (mA) Quiescent Active
CR10X Measurement and Control System
Page 316
AM416 Wiring Diagram For Thermocouple and Soil Moisture Block Measurements EXAMPLE PROGRAM MULTIPLEXING THERMOCOUPLES AND SOIL MOISTURE BLOCK * 1 01: 600 Table 1 Programs Sec. Execution Interval 01: P11 01: 1 02: 4 03: 1 04: 1 05: 1 06: 0 Temp 107 Probe Rep IN ...
AM416 Wiring Diagram For Thermocouple and Soil Moisture Block Measurements EXAMPLE PROGRAM MULTIPLEXING THERMOCOUPLES AND SOIL MOISTURE BLOCK * 1 01: 600 Table 1 Programs Sec. Execution Interval 01: P11 01: 1 02: 4 03: 1 04: 1 05: 1 06: 0 Temp 107 Probe Rep IN ...
CR10X Measurement and Control System
Page 353
...16, 8-9 Using Storage Module with 4-5 Alkaline power supply 14-2 AM25T Solid State Thermocouple Multiplier 7-5 Programming example 8-11 AM416 Multiplexer 8-3 Analog ground definition OV-4 Analog inputs OV-4 Analog output, see SDM-AO4 Analog to computer/printer 1-11 Table E-1 Terminal or computer... with Single Diff. CR10X INDEX ∗ Modes, see Modes 1/X - [Instruction 42] 10-2 3 Wire Half Bridge - [Instruction 7] 9-5, 13-18, 13-19, 13-20 Programming Example 7-9 3WHB10K - 10 K ohm 3-Wire Half Bridge Module 7-9 4 Wire Full Bridge, see Full Bridge with terminal ...
...16, 8-9 Using Storage Module with 4-5 Alkaline power supply 14-2 AM25T Solid State Thermocouple Multiplier 7-5 Programming example 8-11 AM416 Multiplexer 8-3 Analog ground definition OV-4 Analog inputs OV-4 Analog output, see SDM-AO4 Analog to computer/printer 1-11 Table E-1 Terminal or computer... with Single Diff. CR10X INDEX ∗ Modes, see Modes 1/X - [Instruction 42] 10-2 3 Wire Half Bridge - [Instruction 7] 9-5, 13-18, 13-19, 13-20 Programming Example 7-9 3WHB10K - 10 K ohm 3-Wire Half Bridge Module 7-9 4 Wire Full Bridge, see Full Bridge with terminal ...