User Manual
Page 1
User's Manual EXTENDED BATTERY MODULE (EBM) BP36V60ART2U BP72V60ART2U Cyber Power Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Phone: 877-297-6937 Fax: 952-403-0009 http://www.cyberpowersystems.com K01-0000515-03
User's Manual EXTENDED BATTERY MODULE (EBM) BP36V60ART2U BP72V60ART2U Cyber Power Systems (USA), Inc. 4241 12th Avenue East Suite 400 Shakopee, MN 55379 Phone: 877-297-6937 Fax: 952-403-0009 http://www.cyberpowersystems.com K01-0000515-03
User Manual
Page 2
.../3KVA extended battery module Tie plate (1) M5X7L black flat head screws (8) User's manual Register card M5X12L black pan head screws (12) Rackmount left rail Rackmount right rail Left hanging bracket Right hanging bracket IEC320 C14 to NEMA 5-15P power cord M5X6L ...2020 Cyber Power Systems, Inc. Additional parallel-connected EBM provide the UPS for variety of Cyber Power UPS systems. When combining with the UPS, the EBM provides extended runtime with a 36VDC/72VDC external connection. OVERVIEW The CyberPower extended battery modules (BP36V60ART2U / BP72V60ART2U) support 60A polarized...
.../3KVA extended battery module Tie plate (1) M5X7L black flat head screws (8) User's manual Register card M5X12L black pan head screws (12) Rackmount left rail Rackmount right rail Left hanging bracket Right hanging bracket IEC320 C14 to NEMA 5-15P power cord M5X6L ...2020 Cyber Power Systems, Inc. Additional parallel-connected EBM provide the UPS for variety of Cyber Power UPS systems. When combining with the UPS, the EBM provides extended runtime with a 36VDC/72VDC external connection. OVERVIEW The CyberPower extended battery modules (BP36V60ART2U / BP72V60ART2U) support 60A polarized...
User Manual
Page 3
... to position an EBM on the floor or in a rackmount system. Please follow the instructions below for positioning the EBM in place. The EBM takes up 2 rack units. Position the guide screws on the rack. This is especially important to growing organizations with the M5X6L*6pcs screws... square holes to the EBM using the provided M5X7L*8pcs screws and tighten two hanging brackets with changing needs that value having the option to attach the mounting brackets. Step 2: Rackmount ears & hanging brackets installation Attach two rackmount ears to temporarily support the rails in the rack.
... to position an EBM on the floor or in a rackmount system. Please follow the instructions below for positioning the EBM in place. The EBM takes up 2 rack units. Position the guide screws on the rack. This is especially important to growing organizations with the M5X6L*6pcs screws... square holes to the EBM using the provided M5X7L*8pcs screws and tighten two hanging brackets with changing needs that value having the option to attach the mounting brackets. Step 2: Rackmount ears & hanging brackets installation Attach two rackmount ears to temporarily support the rails in the rack.
User Manual
Page 4
...to the rear of the rack with the front of the rack. (Located in the rack with two M5X12L screws and two plastic washers. HARDWARE INSTALLATION Step 4: Adjust rackmount rails to fit your rack Adjust the rail depth to pull the EBM out. Step 5: Place and secure the EBM on...the rack. (Located in position 1 & position 4) Tighten the M5X12L screws on the EBM into the rails mounted in position 2 & position 5) 3 Copyright © 2020 Cyber Power Systems, Inc. Secure the EBM to your rack with two screws and two plastic washers at the front of the unit facing toward you. Attach...
...to the rear of the rack with the front of the rack. (Located in the rack with two M5X12L screws and two plastic washers. HARDWARE INSTALLATION Step 4: Adjust rackmount rails to fit your rack Adjust the rail depth to pull the EBM out. Step 5: Place and secure the EBM on...the rack. (Located in position 1 & position 4) Tighten the M5X12L screws on the EBM into the rails mounted in position 2 & position 5) 3 Copyright © 2020 Cyber Power Systems, Inc. Secure the EBM to your rack with two screws and two plastic washers at the front of the unit facing toward you. Attach...
User Manual
Page 5
... of this user manual for instructions. Step 2: Rackmount ears installation Attach the included rackmount ears to the battery replacement section in this unit, it at the front of the rack (square holes 2 and 5 as shown below) Step 1: Remove side dust covers Remove seven dust covers from screw holes as shown below . 4 Copyright © 2020 Cyber Power Systems...
... of this user manual for instructions. Step 2: Rackmount ears installation Attach the included rackmount ears to the battery replacement section in this unit, it at the front of the rack (square holes 2 and 5 as shown below) Step 1: Remove side dust covers Remove seven dust covers from screw holes as shown below . 4 Copyright © 2020 Cyber Power Systems...
User Manual
Page 6
... range). Insert dust covers into the screw holes that are not being used. CAUTION! CAUTION! The battery can energize hazardous live parts inside even when the AC input power is present (Please see specifications for a tower configuration. Gently lift the LCD module out. Step 2: Attach the base stands and ... indoor area free of electric shock, do not remove the top cover. In case of the risk of conductive contaminants. HARDWARE INSTALLATION VERTICAL/TOWER INSTALLATION Step 1: Adhere the rubber feet on the bottom side of base stands Adhere the protective rubber feet on the bottom side of...
... range). Insert dust covers into the screw holes that are not being used. CAUTION! CAUTION! The battery can energize hazardous live parts inside even when the AC input power is present (Please see specifications for a tower configuration. Gently lift the LCD module out. Step 2: Attach the base stands and ... indoor area free of electric shock, do not remove the top cover. In case of the risk of conductive contaminants. HARDWARE INSTALLATION VERTICAL/TOWER INSTALLATION Step 1: Adhere the rubber feet on the bottom side of base stands Adhere the protective rubber feet on the bottom side of...
User Manual
Page 7
Service to daisy chain the next EBM. Input ...the UPS. BP36V60ART2U / BP72V60ART2U CONNECTION #1 : UPS WITH ONE EXTENDED BATTERY MODULE Step 1: Turn off the DC breaker of a downstream EBM. 4. On-board Replaceable Fuse Cover Replaceable fuse is accessible from EBM upstream 5. Step 4: Rotate the battery cable retention...cover for optional Fast Charge function) AC power connectivity to disconnect battery output. Step 3: Use the output cable of the EBM. 6 Copyright © 2020 Cyber Power Systems, Inc. BASIC OPERATION EXTENDED BATTERY MODULE FRONT/REAR PANEL DESCRIPTION 1. DC...
Service to daisy chain the next EBM. Input ...the UPS. BP36V60ART2U / BP72V60ART2U CONNECTION #1 : UPS WITH ONE EXTENDED BATTERY MODULE Step 1: Turn off the DC breaker of a downstream EBM. 4. On-board Replaceable Fuse Cover Replaceable fuse is accessible from EBM upstream 5. Step 4: Rotate the battery cable retention...cover for optional Fast Charge function) AC power connectivity to disconnect battery output. Step 3: Use the output cable of the EBM. 6 Copyright © 2020 Cyber Power Systems, Inc. BASIC OPERATION EXTENDED BATTERY MODULE FRONT/REAR PANEL DESCRIPTION 1. DC...
User Manual
Page 8
...setting to fix battery cable. Please see their respective User Manuals for instructions. 7 Copyright © 2020 Cyber Power Systems, Inc. To do this via PowerPanel® Business Edition Agent. Step 5: Rotate the battery cable retention bracket and tighten the two screws to match the number of the 1st EBM. Step 2: Turn... off the DC breaker of the 2nd Battery module. Step 6: Use a power cord to remove the battery cable retention bracket of installed units. This operation can also be done if there is an RMCARD installed in the UPS, or via the LCD...
...setting to fix battery cable. Please see their respective User Manuals for instructions. 7 Copyright © 2020 Cyber Power Systems, Inc. To do this via PowerPanel® Business Edition Agent. Step 5: Rotate the battery cable retention bracket and tighten the two screws to match the number of the 1st EBM. Step 2: Turn... off the DC breaker of the 2nd Battery module. Step 6: Use a power cord to remove the battery cable retention bracket of installed units. This operation can also be done if there is an RMCARD installed in the UPS, or via the LCD...
User Manual
Page 9
BASIC OPERATION EXTENDED BATTERY MODULES CONFIGURATION The UPS can be configured to reflect the correct estimated run-times for the number of EBM installed by using the LCD Control Panel to select the number of LCD display. 6. Press the "...on the second column of EBM installed. 1. The first configuration number will be prompted to save the selection, if so press the "ENTER" button to save the setting. 8. Configure Submenu Available Settings EBM Number = [0] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] Default Settings 0 8 Copyright © 2020 Cyber Power Systems, Inc. Press the ...
BASIC OPERATION EXTENDED BATTERY MODULES CONFIGURATION The UPS can be configured to reflect the correct estimated run-times for the number of EBM installed by using the LCD Control Panel to select the number of LCD display. 6. Press the "...on the second column of EBM installed. 1. The first configuration number will be prompted to save the selection, if so press the "ENTER" button to save the setting. 8. Configure Submenu Available Settings EBM Number = [0] [1] [2] [3] [4] [5] [6] [7] [8] [9] [10] Default Settings 0 8 Copyright © 2020 Cyber Power Systems, Inc. Press the ...
User Manual
Page 10
... metal parts on the battery retaining cover. Step 1: Remove the front panels Step 2: Remove the retaining screws from the wall receptacle before servicing the battery. This operation can cause severe burns. Battery replacement should be performed by Cyber Power Systems. Use of batteries. Cyber Power Systems encourages environmentally sound methods for detailed instructions. 9 Copyright © 2020 Cyber Power Systems, Inc. Battery Replacement Please...
... metal parts on the battery retaining cover. Step 1: Remove the front panels Step 2: Remove the retaining screws from the wall receptacle before servicing the battery. This operation can cause severe burns. Battery replacement should be performed by Cyber Power Systems. Use of batteries. Cyber Power Systems encourages environmentally sound methods for detailed instructions. 9 Copyright © 2020 Cyber Power Systems, Inc. Battery Replacement Please...
User Manual
Page 11
... TECHNICAL SPECIFICATIONS BP36V60ART2U BP72V60ART2U 36Vdc 100~125Vac 60A 72Vdc 16.9 x 17 x 3.5in. (430 x 433 x 88mm) 50.6lbs(23.0Kg) 23.6 x 17 x 3.5in. (600 x 433 x 88mm) 96.8lbs(44.0Kg) (6) (12V9AH) (2 x Banks of 3 Batteries) (12) (12V9AH) (2 x Banks of Connected Equipment, a repair cost estimate for instructions. 2. Contact technical support to insufficient runtime. Pack and ship the product to CyberPower...
... TECHNICAL SPECIFICATIONS BP36V60ART2U BP72V60ART2U 36Vdc 100~125Vac 60A 72Vdc 16.9 x 17 x 3.5in. (430 x 433 x 88mm) 50.6lbs(23.0Kg) 23.6 x 17 x 3.5in. (600 x 433 x 88mm) 96.8lbs(44.0Kg) (6) (12V9AH) (2 x Banks of 3 Batteries) (12) (12V9AH) (2 x Banks of Connected Equipment, a repair cost estimate for instructions. 2. Contact technical support to insufficient runtime. Pack and ship the product to CyberPower...
User Manual
Page 12
...the Cyber Power unit. 4. This warranty only covers the original purchaser. How Do You Get Warranty Service? 1. Before contacting CyberPower, identify Your Product model number, and the Purchase Date. 2. Email us at [email protected] or Call us at (877) 297-6937 or write to repair or replace the ...Product (if defective) within 10 days of your purchase, you will be required to provide proof of purchase.) LIMITED WARRANTY Read the following terms and conditions carefully before using the CyberPower BP36V60ART2U / BP72V60ART2U.By using it with...
...the Cyber Power unit. 4. This warranty only covers the original purchaser. How Do You Get Warranty Service? 1. Before contacting CyberPower, identify Your Product model number, and the Purchase Date. 2. Email us at [email protected] or Call us at (877) 297-6937 or write to repair or replace the ...Product (if defective) within 10 days of your purchase, you will be required to provide proof of purchase.) LIMITED WARRANTY Read the following terms and conditions carefully before using the CyberPower BP36V60ART2U / BP72V60ART2U.By using it with...
User Manual
Page 13
...EXCEPT FOR (AND ONLY FOR) the specific limited agreement of CyberPower to the Product. 4. transients, surges... AC Power Line Transients, spikes, or surges on properly installed, grounded and code-compliant 120 volt power lines ...instruction manual, or warnings provided with the Product, such as excluded above limitation may not apply to the Product, surge suppressor, or power tap. For further information please feel free to contact CyberPower...replaced due to properly wired and grounded outlets (including compliance with electrical and safety codes of software. 2. LIMITED WARRANTY Who ...
...EXCEPT FOR (AND ONLY FOR) the specific limited agreement of CyberPower to the Product. 4. transients, surges... AC Power Line Transients, spikes, or surges on properly installed, grounded and code-compliant 120 volt power lines ...instruction manual, or warnings provided with the Product, such as excluded above limitation may not apply to the Product, surge suppressor, or power tap. For further information please feel free to contact CyberPower...replaced due to properly wired and grounded outlets (including compliance with electrical and safety codes of software. 2. LIMITED WARRANTY Who ...
User Manual
Page 14
... Tech Support department with installation, troubleshooting, or general product questions. The Class B digital apparatus meets all requirements of the FCC Rules. Need Additional Help? Reproduction in whole or in part without permission is likely to radio communications. Shielded signal cables must be required to Part 15 of the Canadian Interference-Causing Equipment Regulation. For BP36V60ART2U Online...
... Tech Support department with installation, troubleshooting, or general product questions. The Class B digital apparatus meets all requirements of the FCC Rules. Need Additional Help? Reproduction in whole or in part without permission is likely to radio communications. Shielded signal cables must be required to Part 15 of the Canadian Interference-Causing Equipment Regulation. For BP36V60ART2U Online...
Datasheet
Page 1
... to match the UPS form factor. Replacement Battery Cartridge (1) RB1290X3R & (1) RB1290X3L Typical Recharge Time Expansion Ready (Daisy-Chain) Battery Size 4 Hours (0-90%) Yes 12 V / 9 Ah Hot Swappable Yes User Replaceable Battery Yes This EBM takes 2U of whether one or ten EBMS are installed, and comes with a three-year warranty. ELIGIBLE MODELS • OL1000RTXL2U • OL1000RTXL2UN • OL1500RTXL2U...
... to match the UPS form factor. Replacement Battery Cartridge (1) RB1290X3R & (1) RB1290X3L Typical Recharge Time Expansion Ready (Daisy-Chain) Battery Size 4 Hours (0-90%) Yes 12 V / 9 Ah Hot Swappable Yes User Replaceable Battery Yes This EBM takes 2U of whether one or ten EBMS are installed, and comes with a three-year warranty. ELIGIBLE MODELS • OL1000RTXL2U • OL1000RTXL2UN • OL1500RTXL2U...
Datasheet
Page 2
All rights reserved. CyberPower is a registered trademark and brand of their respective owners. All other trademarks are the property of Cyber Power Systems (USA), Inc. PHYSICAL Rack Size Mounting Hardware Enclosure Construction Dimensions (...FCC Part 15 Class B Product Warranty 3 Year Limited Warranty Extended 2-Year Warranty WEXT5YR-BP1 ©2020 Cyber Power Systems (USA), Inc. CyberPower reserves the right to change, without notice, marketing programs, product offerings and specifications. www.cyberpowersystems.com BP36V60ART2U | EXTENDED BATTERY MODULE SPECIFICATIONS ...
All rights reserved. CyberPower is a registered trademark and brand of their respective owners. All other trademarks are the property of Cyber Power Systems (USA), Inc. PHYSICAL Rack Size Mounting Hardware Enclosure Construction Dimensions (...FCC Part 15 Class B Product Warranty 3 Year Limited Warranty Extended 2-Year Warranty WEXT5YR-BP1 ©2020 Cyber Power Systems (USA), Inc. CyberPower reserves the right to change, without notice, marketing programs, product offerings and specifications. www.cyberpowersystems.com BP36V60ART2U | EXTENDED BATTERY MODULE SPECIFICATIONS ...