Fluke 1630-2 FC Support and Manuals

Get Help and Manuals for this Fluke item

View All Support Options Below
Free Fluke 1630-2 FC manuals!
Problems with Fluke 1630-2 FC?

Ask a Question

Most Recent Fluke 1630-2 FC Questions

Cal Er Show , How To Remove It.
In Fluke 1630-2Fc, testing of earth value it's showing CAL Erhow to remove it.?
(Posted by sudhakartripathispn 23 days ago)
Cal Err Message Is Showing While On The Clamp Meter
CAL Err message is showing while power on the clamp meter.No buttons are functioning after this erro...
(Posted by kvramesh 1 year ago)
How Do I Clear Cal Er
(Posted by mokwowe 2 years ago)

Popular Fluke 1630-2 FC Manual Pages

FE 1630 Users Manual - Page 1

® 1630 Earth Ground Clamp Users Manual PN 2729710 October 2006 © 2006 Fluke Corporation, All rights reserved. Printed in China All product names are trademarks of their respective companies.
FE 1630 Users Manual - Page 2

... authority to extend a greater or different warranty on the date of repair/replacement parts when product purchased in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by use and service. If any product which is warranted to be error free or operate without interruption. P.O. Fluke reserves the right to invoice Buyer for damage in accordance with...
FE 1630 Users Manual - Page 3

... Functions 9 Using the High and Low Alarms 9 Setting the Sampling Interval 10 Logging Data 11 Reading Data Stored in Memory 12 Clearing Memory 12 Canceling Auto-Power Off 12 Maintenance 12 Cleaning the Clamp 13 Replacing the Battery 13 Specifications 14 Electrical Specifications 14 General Specification 14 Ground Loop Resistance 15 Ground Leakage Current mA 15 Ground Leakage Current...
FE 1630 Users Manual - Page 4

1630 Users Manual ii
FE 1630 Users Manual - Page 5

Ground Resistance Measurement Principles 7 4. Alarm Functions 9 6. Display Features 5 3. Ground Leakage Current Measurement 8 5. Stored Data Display 12 iii Setting the Sampling Interval 11 7. List of Figures Figure Title Page 1. 1630 Earth Ground Clamp Features 4 2. Display Features 5 List of Tables Table Title Page 1. 1630 Earth Ground Clamp Features 4 2.
FE 1630 Users Manual - Page 7

... Earth Ground Clamp (hereafter called the "the Clamp") is a hand-held battery-operated clamp that measures the ground resistance of lightning protection systems Standard Accessories The following standard accessories are provided with the Clamp: 1 9-V alkaline battery (type IEC 6F22, NEDA 1604 installed) 1 Resistance test/check loop 1 1630 Users Manual 1 Carrying Case 1 The Clamp can be used...
FE 1630 Users Manual - Page 8

... register.fluke.com Safety Information XWRead First: Safety Information To ensure safe operation and service of the Clamp housing or output cable insulation. Individual protective equipment must be used to local and national safety codes. Also look for cracks or missing portions of the 1630 Earth Ground Clamp, follow these instructions: • Read the operating instructions before use and...
FE 1630 Users Manual - Page 9

.... Earth Ground Clamp Symbols • CAT II equipment is designed to protect against transients from energy-consuming equipment supplied from the fixed installation, such as TVs, PCs, portable tools, and other household appliances. • CAT III equipment is designed to relevant European Union directives ~ Do not dispose of this manual. , W X T M P May be used on the Clamp or...
FE 1630 Users Manual - Page 10

... to hold the displayed value. 1630 Users Manual Getting Acquainted with the Clamp Refer to Figures 1 and 2 and Tables 1 and 2 to become more familiar with the Clamp's features. 1 1630 EARTH GROUND CLAMP HOLD 2 OFF mA A 3 7 CAT 300 V 4 9 FUNC REC 5 8 6 Figure 1. 1630 Earth Ground Clamp Features Table 1. 1630 Earth Ground Clamp Features eht01f.eps Number Description A Jaws...
FE 1630 Users Manual - Page 12

...now or during self-calibration or calibration will show CAL7, CAL6,.....CAL2, CAL1. Attach the Clamp to the electrode or ground rod to finish before making measurements. Note Do not attach the Clamp to the Ω function. After power is completed. 4. Figure 3 illustrates the ground resistance measurement principles. 1630 Users Manual Using the Clamp Ground Resistance Measurements To...
FE 1630 Users Manual - Page 13

... resistance measurements principle: Earth Ground Clamp Using the Clamp 1630 OFF mA A 30C0AVT FUNC REC EARTH GROUND CLAMP HOLD Rg Equivalent circuit diagram: 1630 EARTH GROUND CLAMP R1 R2 R1 R2 R3 .....Rn .....Rn HOLD mA A OFF CA3T00 V REC FUNC Rg 1630 HOLD mA A OFF CA3T00 V EARTH GROUND CLAMP Rg REC FUNC Figure 3. Ground Resistance Measurement Principles eht03f.eps 7
FE 1630 Users Manual - Page 14

..., or any foreign substances. 2. Turn the Clamp on the display. 1630EARTH GROUND CLAMP HOLD OFF mA A CA3T00 V REC FUNC Figure 4. Ground Leakage Current Measurement eht05f.eps 8 Figure 4 shows a connection for a ground leakage current measurement. 4. 1630 Users Manual Ground Leakage Current Measurement To perform a ground leakage current measurement test: 1. Open the jaws and...
FE 1630 Users Manual - Page 16

... The values of the high and low alarm are restored when the Clamp is turned on. Setting the Sampling Interval 1. The Clamp shows the current sampling interval in the upper display. Press F until...display. 2. HI value will be adjusted to 255 seconds. 1630 Users Manual Note • If the HI value is set at OL, or the LO value is set at 0, the ALARM function will be disabled. • ...
FE 1630 Users Manual - Page 18

... lower display. Maintenance XWWarning To avoid possible electric shock or personal injury, repairs or servicing not covered in Memory 1. Press F until NO. Press E or D...Clamp on . To cancel Auto-Power Off, press F and then turn the Clamp on the display. The letters CL appear on the display and indicate that Auto-Power Off is reached. 1630 Users Manual Reading Data Stored in this manual...
FE 1630 Users Manual - Page 20

.... 40 mA (in (H) Weight 750 g (1.65 lbs) 14 1630 Users Manual Specifications Electrical Specifications Display 9999 digit liquid crystal display with special symbols Operating Humidity Less than... Non-destructive Current 100 A continuous, 200 A (< 10 sec) 50/60 Hz Accuracy of Calibration Plate 0.5% Data Logging Capacity 116 records Data Logging Interval 1 to IEC 60529/EN 60529 Category ...

Fluke 1630-2 FC Reviews

Do you have an experience with the Fluke 1630-2 FC that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 1630-2 FC Search Terms

The following terms are frequently used to search for Fluke 1630-2 FC support:

Ask a New Question
Use the box below to post a new question about Fluke 1630-2 FC.
Manuals / Documents
Download any of our Fluke 1630-2 FC manuals for free!

We have the following 1 documents available for the Fluke 1630-2 FC:
  • FE 1630 Users Manual
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 1630-2 FC manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 1630-2 FC user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.