User Manual - Page 1

All product names are subject to change without notice. 374 FC/375 FC/376 FC Clamp Meter PN 4705494 September 2015 © 2015 Fluke Corporation. Specifications are trademarks of their respective companies. All rights reserved.
User Manual - Page 5

Introduction The Fluke 374 FC/375 FC/376 FC (the Product) measures true-rms ac current and voltage, dc current and voltage, inrush current, resistance, and capacitance. The illustrations in this manual show the 376 FC. 1 The Flexible Current Probe provides increased display flexibility and allows measurements of awkward sized conductors and improved wire access. The 375 FC and 376 FC also...
User Manual - Page 6

... print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 2 374 FC/375 FC/376 FC Users Manual Contact Fluke To contact Fluke, call one of the following telephone numbers: • Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) • Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) • Canada: 1-800-36-FLUKE (1-800-363-5853) • Europe...
User Manual - Page 8

... exposed. • Before each terminal and earth ground. • De-energize the circuit or wear personal protective equipment in compliance with local and national safety codes. 374 FC/375 FC/376 FC Users Manual • Do not exceed the Measurement Category (CAT) rating of the lowest rated individual component of the...
User Manual - Page 10

... if the battery leaks. • Have an approved technician repair the Product. 374 FC/375 FC/376 FC Users Manual For safe operation and maintenance of any individual component. 6 Note The Measurement Category (CAT) and voltage rating of any combination of test probe, test probe accessory, current clamp accessory, and the Product is the LOWEST rating of...
User Manual - Page 11

...; Earth Meaning X WARNING. Certified by TÜV SÜD Product Service. HAZARDOUS LIVE conductors. RISK OF DANGER.   Battery. Do not apply to European Union directives.  Consult user documentation. Do not apply around and removal from - HAZARDOUS VOLTAGE. W WARNING. Clamp Meters Safety Information Table 1. Risk of electric shock. additional...
User Manual - Page 12

374 FC/375 FC/376 FC Users Manual Table 1. Product Category: With reference to the equipment types in the WEEE... Do not dispose of the building's low-voltage MAINS installation.  Conforms to relevant Australian EMC standards. ) Certified by CSA Group to the distribution part of the building's low-voltage MAINS installation.  Measurement Category IV is classed as unsorted ...
User Manual - Page 13

Table 2. Replacement Parts Item Qty. Fluke Part or Model Number Battery, AA 1.5 V Battery Door Assembly Test lead set Flexible current probe i2500-10 Flexible current probe i2500-18 Magnet strap STRAP 9 INCHES Soft Case 2 376756 1 4696918 1 TL75 1 3676410 1 3798105 1 669952 1 669960 1 3752958 9 Clamp Meters Replacement Part List Replacement Part List Table 2 lists the ...
User Manual - Page 14

374 FC/375 FC/376 FC Users Manual The Product Clamp Meter 10 fig01.eps
User Manual - Page 17

LOG (375 FC and 376 FC) 2 sec = LOG Clamp Meters The Product Clear Memory (375 FC and 376 FC) + ON + x1 x2 5 sec fig_16.eps 13
User Manual - Page 19

Jaw 0.5 A Clamp Meters The Product Hz (375 FC & 376 FC) > 5 A > 20 A 1 2 fig07.eps 15
User Manual - Page 21

Clamp Meters The Product mV dc (375 FC & 376 FC) fig09_10.eps 17
User Manual - Page 25

Fluke ConnectTM Bluetooth® Connection to FC Tools 1 Fluke Connect TM 2 Connect 3 4 CAPTURE SAVE 5 6 Clamp Meters The Product FC Module SAVE Go to www.flukeconnect.com flukeconnect.eps 21
User Manual - Page 31

Clamp Meters Specifications Distance from Optimum i2500-10 Flex i2500-18 Flex Error A 0.5 in (12.7 mm) 1.4 in (35.6 mm) ±0.5 % B 0.8 in (20.3 mm) 2.0 in (50.8 mm) ±1.0 % C 1.4 in (35.6 mm) 2.5 in (63.5 mm) ±2.0 % Measurement uncertainty assumes centralized ...
User Manual - Page 33

... 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A Frequency via Flexible Current Probe Range 375 FC and 376 FC 5.0 Hz to 500.0 Hz Resolution 0.1 Hz Accuracy 0.5 % ±5 digits Trigger Level 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A Clamp Meters Specifications 29

Fluke 376 FC Reviews

Do you have an experience with the Fluke 376 FC that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fluke yet.

Popular Fluke 376 FC Search Terms

The following terms are frequently used to search for Fluke 376 FC support:

Ask a New Question
Use the box below to post a new question about Fluke 376 FC.
Manuals / Documents
Download any of our Fluke 376 FC manuals for free!

We have the following 1 documents available for the Fluke 376 FC:
  • User Manual
Related Items

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fluke Manuals

Find free Fluke 376 FC manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fluke Reviews

View thousands of Fluke 376 FC user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fluke customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fluke customer service rankings, employee comments and much more from our sister site.

Fluke Recalls

Find comprehensive Fluke recall information updated hourly on RecallOwl.com.