Fujitsu MAX3073NC - SCSI,80, Dell DC961,Hard Drive Support and Manuals

Get Help and Manuals for this Fujitsu item

View All Support Options Below
Free Fujitsu MAX3073NC manuals!
Problems with Fujitsu MAX3073NC?

Ask a Question

Popular Fujitsu MAX3073NC Manual Pages

Specifications - Page 6

... capacity and data format at the time it was shipped, but in this manual, except in cases where models need to the reader's understanding when reading this manual. Preface Glossary The glossary explains technical terms which are called Intelligent Disk Drive (IDD), "drive" or "device" in this manual. The model name of the SCSI interface used . ii C141-C010
Specifications - Page 8

... your opinions or requests on the Comment at the back of this manual comply with the following standards. iv C141-C010 Small Computer System Interface (SCSI) American National Standard for Information Systems --- Preface Related Standards Specifications and functions of products covered by this manual and forward it to understand, opinions from readers are needed.
Specifications - Page 17

...25 Outline of SCSI Bus Error Recovery Processing 1-27 Outline of disk drive error recovery processing 1-27 Reset processing during write...1-29 Table 3.1 Table 3.2 Table 3.3 Table 3.4 Table 3.5 Table 3.6 MODE SENSE Data Type Specifications 3-33 Persistent reservation type codes...3-61 PERSISTENT RESERVE OUT command service action codes 3-64 PERSISTENT RESERVE OUT service actions and valid...
Specifications - Page 68

... (Hierarchical support): Defined the hierarchical addressing model to assign LUN [0/1] [Byte 5] - EncServ (Enclosure service): Enclosure service [0] - RelAdr (Relative addressing): Relative logical block addressing [0] - WBus16 (16-bit wide data transfer): Data transfer on the synchronous mode [1] - When the CHANGE DEFINITION command is set so that the SCSI-2 or SCSI-3 mode...
Specifications - Page 72

... all or part of the CDB. Page Code Page (Hex) 00 80 C0 Function Page code list of supported VPD information Device serial number Operation mode Furthermore, if page codes other than... command for the operation code being queried. a. Command Specifications c. CDB size This field contains the number of bytes in the CDB for a device server that implements command support data but not vital ...
Specifications - Page 79

... CONDITION status (Standard SCSI specification) in response to establish synchronous mode data transfer, no SDTR message is sent from the INIT, the IDD responds normally. * Set at shipping time c)...status which causes a UNIT ATTENTION condition is not reported.) * Set at shipping time d) RSRTY (reselection retry) This specifies the number of a BUS DEVICE RESET message, if a SYNCHRONOUS DATA ...
Specifications - Page 80

... this specification and operates with the settings specified at shipping time i) Spindle motor start delay time This specifies the time after the power is specified in the IDD. If X '00' is specified in this parameter) x (IDD's SCSI ID x 0.1)] seconds from the power is switched on , no matter what value is switched on . "1" (Permitted...
Specifications - Page 92

... of "Page descriptor" supported by the IDD and their page codes and lengths are configured from a "Header," "Block Descriptor" and one or more "Page descriptors" which describe each type of parameter, each type of parameter related to the disk drive's physical attributes, data format, timing for SCSI bus disconnect and reconnect processing, error recovery procedures, etc...
Specifications - Page 122

... describes the handling required for the supporting drive. Support of Element Scope is defined with the SCSI-3 Medium Changer Commands (SMC) standard. Table 3.2 shows the code value for each Type and requirements for write operations. 3-60 C141-C010 The first paragraph describes the handling required for four Type values. Command Specifications Code 0h 1h 2h 3h-Fh...
Specifications - Page 162

.... Therefore, the specification in the following special cases. The INIT can specify the type of self-diagnosis test to the disk drive are executed are in accordance with the "UnitOfl (unit off -line)" bit. The user should present the value displayed in this sense data as repair information to the Fujitsu representative.) Furthermore, error recovery processing...
Specifications - Page 210

... multiple blocks. If the number is specified, the IDD performs rounding processing and sets max value. FSW (force sequential write) (not supported) This bit specifies how ...disk media in the order in the fastest time. q. Non cache buffer size If this field is specified, the IDD performs rounding processing and set 4. This parameter is valid when the SIZE bit specification is not supported...
Specifications - Page 219

...code. C141-C010 4-35 Margin control subpage Supported Saved training configuration value subpage Supported Negotiated setting subpage Supported Report transfer capabilities subpage Supported Reserved ------ Subpage Code This shows the page code...Page Supported Note: For the most recent information, see SPI-4 of a subpage used during Long Page Format specification. Subpage Code ...
Specifications - Page 227

... or disabled and the reporting method when a drive failure is predicted. The log errors bit (LogErr) of zero indicates that the logging of this MODE SELECT parameter is shown in Figure 4.9. 4.1 Mode Parameters 4.1.10 Informational exceptions control page (page code = 1C) The page descriptor format of informational exception conditions within a target is vendor specific.
Specifications - Page 281

...is specified (ARRE = "1"), the EER flag's specification in the "Number of the recovered data and a verify check (...setting terminal, the auto alternate block allocation processing specification is disabled. (2) Auto alternate block allocation processing during WRITE/WRITE EXTENDED command detects any Servo error (e.g. When errors in the MODE SELECT parameters. 5.3 Disk Drive Error...
Specifications - Page 282

...setting terminal, the auto alternate block allocation processing specification is disabled. 5.3.3 Error recovery processing control The INIT can, by specifying the MODE SELECT parameters, can specify the number of retries, normally, it is recommended that the default value or a greater number of error related to the disk drive...for those errors. Read/Write Error Recovery Parameters (Page Code = ...

Fujitsu MAX3073NC Reviews

Do you have an experience with the Fujitsu MAX3073NC that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Fujitsu yet.

Popular Fujitsu MAX3073NC Search Terms

The following terms are frequently used to search for Fujitsu MAX3073NC support:

Ask a New Question
Use the box below to post a new question about Fujitsu MAX3073NC.
Manuals / Documents
Download any of our Fujitsu MAX3073NC manuals for free!

We have the following 1 documents available for the Fujitsu MAX3073NC:
  • Specifications

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Fujitsu Manuals

Find free Fujitsu MAX3073NC - SCSI,80, Dell DC961,Hard Drive manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Fujitsu Reviews

View thousands of Fujitsu MAX3073NC - SCSI,80, Dell DC961,Hard Drive user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Fujitsu customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Fujitsu customer service rankings, employee comments and much more from our sister site.

Fujitsu Recalls

Find comprehensive Fujitsu recall information updated hourly on RecallOwl.com.