Heat Pump Installation Manual
Page 7
...2" 10.25 590 360 615 R410A A1 245 245 285 285 37 37 36.5 x 31 x 42 36.5 x 31 x 42 Outdoor Use USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 140 240/1/60 208-230/3/60 7.2 34.5 32.1/2.4/34.5 185/4.3/189.3 42.5 50 70 140000 5.7 130000 5.5 85000 4 58.5 280 320...operation • High (590PSI) and low (80PSI) refrigerant pressure switches monitoring extreme operation • Compressor sound blanket • Corrosion resistant evaporator fins Models Voltage/Phase/Hz 100 240/1/60 TABLE 2: SPECIFICATIONS 112 120 H/C 240/1/60 240/1/60 125 240/1/60 Power Input (kW) 80A-80RH-80W ...
...2" 10.25 590 360 615 R410A A1 245 245 285 285 37 37 36.5 x 31 x 42 36.5 x 31 x 42 Outdoor Use USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 140 240/1/60 208-230/3/60 7.2 34.5 32.1/2.4/34.5 185/4.3/189.3 42.5 50 70 140000 5.7 130000 5.5 85000 4 58.5 280 320...operation • High (590PSI) and low (80PSI) refrigerant pressure switches monitoring extreme operation • Compressor sound blanket • Corrosion resistant evaporator fins Models Voltage/Phase/Hz 100 240/1/60 TABLE 2: SPECIFICATIONS 112 120 H/C 240/1/60 240/1/60 125 240/1/60 Power Input (kW) 80A-80RH-80W ...
Heat Pump Installation Manual
Page 16
.... 2. Use 20 AWG wire for remote control via independent 2-wire connections. Heat Only models connect the remote relay to J28 connection L(if applicable) on the compressor to starting the heater. 15 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Turn the unit on /off when both relays are no water leaks... of heater components and their locations in heating mode. Remote Control Connection The heater is equipped for runs over 30 feet. Heat/Cool models connect the heating remote relay to terminal J7 and cooling remote relay to the local set point. Connect the Heating remote relay to the...
.... 2. Use 20 AWG wire for remote control via independent 2-wire connections. Heat Only models connect the remote relay to J28 connection L(if applicable) on the compressor to starting the heater. 15 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Turn the unit on /off when both relays are no water leaks... of heater components and their locations in heating mode. Remote Control Connection The heater is equipped for runs over 30 feet. Heat/Cool models connect the heating remote relay to terminal J7 and cooling remote relay to the local set point. Connect the Heating remote relay to the...
Heat Pump Installation Manual
Page 17
... operation, high temperature, high-pressure sub cooled liquid Refrigerant (A) is throttled by the pool pump, is currently active. 16 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS The heater will operate in case of the following events: • Excessively high refrigerant pressure • Excessively high water... • Loss of refrigerant • Fan Motor Failure • Evaporator Freeze-up • Low Ambient Temperature Control Setup Heat Only Models This pool heater is currently active. HEAT - COOL - It will then function automatically to protect the unit in HEAT or COOL mode...
... operation, high temperature, high-pressure sub cooled liquid Refrigerant (A) is throttled by the pool pump, is currently active. 16 USE ONLY HAYWARD GENUINE REPLACEMENT PARTS The heater will operate in case of the following events: • Excessively high refrigerant pressure • Excessively high water... • Loss of refrigerant • Fan Motor Failure • Evaporator Freeze-up • Low Ambient Temperature Control Setup Heat Only Models This pool heater is currently active. HEAT - COOL - It will then function automatically to protect the unit in HEAT or COOL mode...