Popular HP Integrity rx8640 Manual Pages
Internal Cabling Guide for HP Smart Array Controllers - Page 3
Cabling for the HP Integrity rx7640 Server Installing the HP Smart Array 6402 or 6404 Controller Card 45 Recabling for RAID 23
3. Cabling for the HP Integrity rx8640 Server Installing the HP Smart Array Controller Card 13 Single Partition RAID Configuration 14 RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives 15 Dual Partition Configurations 17 RAID Cabling ...
Internal Cabling Guide for HP Smart Array Controllers - Page 19
... the HP Integrity rx8640 Server Single Partition RAID Configuration
RAID Cabling for IO Chassis 0 (Top Left and Top Right Hot Plug Hard Drives)
To set up the...installed.
Identify the new cables using the colored cable ties which is installed in front of one on the Mass Storage Backplane. Step 6. Verify that the HP Smart Array controller card is labeled "This Connector to the HP...
Internal Cabling Guide for HP Smart Array Controllers - Page 26
...1
8
8
3
A2
6
SEU
Bottom Left
8
0
1
8
8
3
A1
6
SEU
Bottom Right
22
Chapter 2 Table 2-2
Hard Drive Mapping for the HP Integrity rx8640 Server Insight Manager 7 Hard Disk Drive Mapping
Insight Manager 7 Hard Disk Drive Mapping
The previously described internal drive configuration produces the following mapping in IM7 when events occur on a target HDD, as shown in Table 2-2.
Internal Cabling Guide for HP Smart Array Controllers - Page 27
... for the HP Integrity rx8640 Server Configuring the Server Firmware and Software for RAID
Configuring the Server Firmware and Software for RAID
To complete the installation and set up RAID for your server's internal hot swap drives, follow the procedures given in the Smart Array Controller User Guide: • Configure your HP Smart Array controller card in an HP Integrity server (use HP Smart...
Internal Cabling Guide for HP Smart Array Controllers - Page 28
Cabling for the HP Integrity rx8640 Server Configuring the Server Firmware and Software for RAID
24
Chapter 2
HP-UX 11i v3 Dynamic nPartitions - Features and Configuration Recommendations - Page 21
...-based HP servers that support HP-UX 11i v3 Dynamic nPartitions operations:
Cell capacity Two-cell Servers
Four-cell Servers
HP 9000 Superdome Servers HP Integrity Superdome Servers
Server model
HP 9000 rp7420 Server HP 9000 rp7440 Server HP Integrity rx7620 Server HP Integrity rx7640 Server
HP 9000 rp8420 Server HP 9000 rp8440 Server HP Integrity rx8620 Server HP Integrity rx8640 Server
HP 9000...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 4
Bulk Power Supply Cooling...38 PCI/Mass Storage Section Cooling 38 Standby Cooling...38 Typical HP Integrity rx8640 Server Power Dissipation and Cooling 39 Typical HP 9000 rp8440 Server Power Dissipation and Cooling 39 Acoustic Noise Specification...40 Air Flow...40
A Templates...41
Equipment Footprint Templates...41 Computer Room Layout Plan...41
Index...45
4 Table of Contents
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 7
... 2-3 Example Weight Summary...33 2-4 Weight Summary...34 2-5 Power Cords...35 2-6 HP Integrity rx8640 and HP 9000 rp8440 AC Power Requirements 35 2-7 HP Integrity rx8640 System Power Requirements 36 2-8 HP 9000 rp8440 System Power Requirements 36 2-9 Example ASHRAE Thermal Report 37 2-10 Typical HP Integrity rx8640 Server Configurations 39 2-11 Typical HP 9000 rp8440 Server Configurations 39...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 13
1 HP Integrity rx8640 and HP 9000 rp8440 Server Overview
The HP Integrity rx8640 server and the HP 9000 rp8440 server are divided into two I/O chassis. See Chapter 2 (page 33). The server is equal to six N+1 bulk power supplies. • Two N+1 PCI-X power supplies. • N+1 hot-swappable system clock oscillators. • Sixteen PCI-X slots are members of the HP business-critical ...
Site Preparation Guide, Fourth Edition - HP Integrity rx8640, HP 9000 rp8440 Servers - Page 39
... Specifications 39 Typical HP Integrity rx8640 Server Power Dissipation and Cooling
Table 2-10 provides calculations for the rx8640 configurations as...support these devices.
Refer to determine the power and air-conditioning that will operate at full speed during initial installation or as described in the table. the resulting heat from the cabinet. Typical HP 9000 rp8440 Server...
Windows Integrity Management Agents Reference - Page 47
... fault has occurred. Recommended Action: Contact HP Support personnel to latest revision. Recommended Action: Contact HP Support personnel to troubleshoot the problem. Probable Cause: A hardware fault has occurred. SNMP Trap: hpevtPdhcSmbusReadFailed - 8136 in HPIFPTRAP.MIB.
8127 Error
Data field contains data meant for firmware debug only.
Restore the GSP. Probable Cause...
Windows Integrity Management Agents Reference - Page 51
... on the OS side to troubleshoot the problem. Recommended Action: Collect IPMI events and contact HP Support. SNMP Trap: hpevtBootMixedCpuCoreFreqInstalled - 8269 in the Dillon microstatus reg. Check fabric connection between OLA cell and cells already in HPIFPTRAP.MIB.
8269 Warning
CPUs of different maximum core frequencies are installed. Consult chassis codes from the OLA cell...
Windows Integrity Management Agents Reference - Page 61
....
9385 Error
Install PMI Handler Failed Probable Cause: Installation of code Probable Cause: Cell was awakened for the cell or CPU module. Recommended Action: Troubleshoot the fabric and replace backplane or cells. Recommended Action: Troubleshoot the cell and/or replace it was unable to a structure Probable Cause: Hardware connecting cells in the partition experienced a problem such that...
Site Preparation Guide, Third Edition - HP Integrity rx8640 Server Expansion Unit - Page 1
Site Preparation Guide, Server Expansion Unit for the HP Integrity rx8640
Server Expansion Unit for the HP Integrity rx8640
HP Part Number: AB301-9009A Published: September 2007 Edition: Third Edition
Site Preparation Guide, Third Edition - HP Integrity rx8640 Server Expansion Unit - Page 29
... 1925 1516 1345
The air conditioning data in Table 2-7 is 57.1 db (sound pressure level at bystander position) when connected to the HP Integrity rx8640 server as the host system. It is...support these devices. Care should be between 68° F and 77° F (20° C and 25° C) at full speed during initial installation or as described in standby mode. Environmental Specifications...
HP Integrity rx8640 Reviews
Do you have an experience with the HP Integrity rx8640 that you would like to share?
Earn 750 points for your review!
We have not received any reviews for HP yet.
Earn 750 points for your review!