... ready to go . ENGLISH Table of contents VisionPRO® TH8000 Series About your new thermostat Thermostat features 2 Programming at a glance 3 Quick reference to controls 4 Quick reference to status display......... 5 Programming & Operation Clock setting 6 Fan setting 7 System setting 8 Using program schedules 9 Program schedule overrides 12 Vacation hold 14 Special features 15 Screen lock 16 Screen cleaning 17...
... ready to go . ENGLISH Table of contents VisionPRO® TH8000 Series About your new thermostat Thermostat features 2 Programming at a glance 3 Quick reference to controls 4 Quick reference to status display......... 5 Programming & Operation Clock setting 6 Fan setting 7 System setting 8 Using program schedules 9 Program schedule overrides 12 Vacation hold 14 Special features 15 Screen lock 16 Screen cleaning 17...
Owner's Manual
Page 4
... components. • Large touchscreen display with backlight is easy to read-even in the dark. • Select models display and control summer humidity. • Select models accommodate optional outdoor or indoor remote sensors. 69-1894EFS-01 2 Features • 7-day program schedules maximize comfort and economy. • Armchair programming: Just pull thermostat from the wall...
... components. • Large touchscreen display with backlight is easy to read-even in the dark. • Select models display and control summer humidity. • Select models accommodate optional outdoor or indoor remote sensors. 69-1894EFS-01 2 Features • 7-day program schedules maximize comfort and economy. • Armchair programming: Just pull thermostat from the wall...
Owner's Manual
Page 5
... the time and day. Set clock...See page 6 2. Select fan setting: Preset to Heat See page 8 4. Then check the settings below and change if needed: 1. Program schedules: Preset to energy-saving levels while you're at work or asleep (assumes you wake at 6 am, leave at 8 am, return at any time..., and manually adjust the temperature (see pages 12-14). 3 69-1894EFS-01 VisionPRO® TH8000 Series Your new thermostat is pre-programmed and ready to bed at 10 pm See pages 10-13 ENGLISH ONE-TOUCH TEMP CONTROL: You can override the...
... the time and day. Set clock...See page 6 2. Select fan setting: Preset to Heat See page 8 4. Then check the settings below and change if needed: 1. Program schedules: Preset to energy-saving levels while you're at work or asleep (assumes you wake at 6 am, leave at 8 am, return at any time..., and manually adjust the temperature (see pages 12-14). 3 69-1894EFS-01 VisionPRO® TH8000 Series Your new thermostat is pre-programmed and ready to bed at 10 pm See pages 10-13 ENGLISH ONE-TOUCH TEMP CONTROL: You can override the...
Owner's Manual
Page 6
... (see page 11) Press to select fan operation (see page 7) Press to select system type (see page 8) Press to set program schedule (see page 11) MON TUE WED THU FRI SAT SUN OK TO PICK MULTIPLE DAYS 70 FAN AUTO Inside 70 Set To SYSTEM HEAT 6:... Schedule Press to adjust temperature settings (see pages 11-14) Press for more options (select models only) SCHED HOLD CLOCK SCREEN MORE Press to override program schedule (see pages 12-14) Press to set clock (see page 6) M29344 Press to lock keypad for 30 seconds to clean screen (see page 17...
... (see page 11) Press to select fan operation (see page 7) Press to select system type (see page 8) Press to set program schedule (see page 11) MON TUE WED THU FRI SAT SUN OK TO PICK MULTIPLE DAYS 70 FAN AUTO Inside 70 Set To SYSTEM HEAT 6:... Schedule Press to adjust temperature settings (see pages 11-14) Press for more options (select models only) SCHED HOLD CLOCK SCREEN MORE Press to override program schedule (see pages 12-14) Press to set clock (see page 6) M29344 Press to lock keypad for 30 seconds to clean screen (see page 17...
Owner's Manual
Page 7
... Series Temperature setting ENGLISH Fan setting System setting Current time WED 70 FAN AUTO Inside SYSTEM HEAT 6:01 AM 70 Set To Following Schedule Recovery Program schedule on (does not display when off) SCHED HOLD CLOCK SCREEN MORE M29345 Adaptive Intelligent Recovery in effect (see page 15) Other display messages: •...
... Series Temperature setting ENGLISH Fan setting System setting Current time WED 70 FAN AUTO Inside SYSTEM HEAT 6:01 AM 70 Set To Following Schedule Recovery Program schedule on (does not display when off) SCHED HOLD CLOCK SCREEN MORE M29345 Adaptive Intelligent Recovery in effect (see page 15) Other display messages: •...
Owner's Manual
Page 9
..., then press DONE. • On: Fan is always on. • Auto: Fan runs only when the heating or cooling system is programmed, "Auto" will remain active until you 've programmed for different time periods (see page 27 for more information). 7 69-1894EFS-01 ENGLISH Fan setting VisionPRO® TH8000 Series WED 70...
..., then press DONE. • On: Fan is always on. • Auto: Fan runs only when the heating or cooling system is programmed, "Auto" will remain active until you 've programmed for different time periods (see page 27 for more information). 7 69-1894EFS-01 ENGLISH Fan setting VisionPRO® TH8000 Series WED 70...
Owner's Manual
Page 11
You can program four time periods each day, with different settings for maximum energy savings. Set to the time you go to bed and the temperature you are ..., until bedtime. Set to the time you awaken and the temperature you leave for the day. ENGLISH VisionPRO® TH8000 Series Save money by setting program schedules It's easy to the time you leave home and the temperature you want while you want during the evening, until you want overnight (usually...
You can program four time periods each day, with different settings for maximum energy savings. Set to the time you go to bed and the temperature you are ..., until bedtime. Set to the time you awaken and the temperature you leave for the day. ENGLISH VisionPRO® TH8000 Series Save money by setting program schedules It's easy to the time you leave home and the temperature you want while you want during the evening, until you want overnight (usually...
Owner's Manual
Page 12
ENGLISH Operating Manual EnergyStar® settings for maximum cost savings This thermostat is pre-set to adjust times and temperatures of each time period.) Wake (6:00 am) Leave (8:00 am) Return (6:00 pm) Sleep (10:00 pm) ... 10 We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to use EnergyStar® program settings.
ENGLISH Operating Manual EnergyStar® settings for maximum cost savings This thermostat is pre-set to adjust times and temperatures of each time period.) Wake (6:00 am) Leave (8:00 am) Return (6:00 pm) Sleep (10:00 pm) ... 10 We recommend these settings, since they can reduce your heating/cooling expenses by as much as 33%. (See next page to use EnergyStar® program settings.
Owner's Manual
Page 13
... for any unwanted time period. Note: Press FAN to set Wake time for selected day(s). 4. Press day buttons (MON-SUN) to start M29352 1. To adjust program schedules VisionPRO® TH8000 Series ENGLISH Press SCHED SCHED HOLD CLOCK SCREEN MORE Press EDIT M29350 DONE EDIT WAKE LEAVE RETURN SLEEP CANCEL Select day... SUN OK TO PICK MULTIPLE DAYS FAN AUTO 70 HEAT CANCEL PERIOD 6:00 AM 78 COOL DONE WAKE LEAVE RETURN SLEEP CANCEL Set time for program period to select day(s). 3.
... for any unwanted time period. Note: Press FAN to set Wake time for selected day(s). 4. Press day buttons (MON-SUN) to start M29352 1. To adjust program schedules VisionPRO® TH8000 Series ENGLISH Press SCHED SCHED HOLD CLOCK SCREEN MORE Press EDIT M29350 DONE EDIT WAKE LEAVE RETURN SLEEP CANCEL Select day... SUN OK TO PICK MULTIPLE DAYS FAN AUTO 70 HEAT CANCEL PERIOD 6:00 AM 78 COOL DONE WAKE LEAVE RETURN SLEEP CANCEL Set time for program period to select day(s). 3.
Owner's Manual
Page 14
... 69-1894EFS-01 12 To cancel the temporary setting at any time, press CANCEL (or SCHED). ENGLISH Operating Manual Program schedule override (temporary) Adjust temperature WED 70 FAN Inside AUTO SYSTEM HEAT Hold Temperature Until 8:00 AM 73 Set To Heat On SCHED ...HOLD CLOCK SCREEN MORE CANCEL M29353 Press to set . When the timer expires, the program schedule will temporarily override the temperature setting for the current time period. The new temperature will resume. Press CANCEL (or SCHED) to immediately adjust ...
... 69-1894EFS-01 12 To cancel the temporary setting at any time, press CANCEL (or SCHED). ENGLISH Operating Manual Program schedule override (temporary) Adjust temperature WED 70 FAN Inside AUTO SYSTEM HEAT Hold Temperature Until 8:00 AM 73 Set To Heat On SCHED ...HOLD CLOCK SCREEN MORE CANCEL M29353 Press to set . When the timer expires, the program schedule will temporarily override the temperature setting for the current time period. The new temperature will resume. Press CANCEL (or SCHED) to immediately adjust ...
Owner's Manual
Page 15
Whatever temperature you set will turn off the program schedule. Press CANCEL (or SCHED) to cancel "Hold" and resume the program schedule. This will be maintained 24 hours a day until you manually change it or press CANCEL (or SCHED) to resume program schedule 13 69-1894EFS-01 ENGLISH VisionPRO® TH8000 Series Program schedule override (permanent) Press HOLD Adjust temperature WED 70 FAN Inside AUTO SYSTEM 73 Set To Heat On HEAT 8:00 AM Permanent Hold SCHED HOLD CLOCK SCREEN MORE CANCEL M29354 Press HOLD to permanently adjust the temperature.
Whatever temperature you set will turn off the program schedule. Press CANCEL (or SCHED) to cancel "Hold" and resume the program schedule. This will be maintained 24 hours a day until you manually change it or press CANCEL (or SCHED) to resume program schedule 13 69-1894EFS-01 ENGLISH VisionPRO® TH8000 Series Program schedule override (permanent) Press HOLD Adjust temperature WED 70 FAN Inside AUTO SYSTEM 73 Set To Heat On HEAT 8:00 AM Permanent Hold SCHED HOLD CLOCK SCREEN MORE CANCEL M29354 Press HOLD to permanently adjust the temperature.
Owner's Manual
Page 16
... hold ENGLISH 1. Press s or t to set the temperature you want the schedule to select number of days 69-1894EFS-01 This feature can suspend the program schedule for the number of days. Whatever temperature you set will be maintained 24 hours a day for extended periods of days have elapsed, the previously... will resume at the time you select. After this number of time. Press HOLD twice, then press s or t to cancel "Hold" and resume the program schedule. 14 If you want , then press s or t to set the time of day you return earlier than expected, press CANCEL (or SCHED) to select ...
... hold ENGLISH 1. Press s or t to set the temperature you want the schedule to select number of days 69-1894EFS-01 This feature can suspend the program schedule for the number of days. Whatever temperature you set will be maintained 24 hours a day for extended periods of days have elapsed, the previously... will resume at the time you select. After this number of time. Press HOLD twice, then press s or t to cancel "Hold" and resume the program schedule. 14 If you want , then press s or t to set the time of day you return earlier than expected, press CANCEL (or SCHED) to select ...
Owner's Manual
Page 17
... "learn" how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is 70° by the time you wake at the time you set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. For example: Set the Wake time to 70...
... "learn" how long the furnace and air conditioner take to reach programmed temperature settings, so the temperature is 70° by the time you wake at the time you set to Auto, the thermostat automatically selects heating or cooling depending on the indoor temperature. For example: Set the Wake time to 70...
Owner's Manual
Page 25
ENGLISH Advanced functions VisionPRO® TH8000 Series Program schedule on/off Function 0160 Press s/t to turn the program schedule on or off: Options: 0 Program schedule is off Function 0330 The thermostat is on /off . Thermostat is non-programmable. 4 Program schedule is pre-programmed to automatically adjust to daylight savings time. Temperature format (°F/°C) Function 0320 Press s/t to...
ENGLISH Advanced functions VisionPRO® TH8000 Series Program schedule on/off Function 0160 Press s/t to turn the program schedule on or off: Options: 0 Program schedule is off Function 0330 The thermostat is on /off . Thermostat is non-programmable. 4 Program schedule is pre-programmed to automatically adjust to daylight savings time. Temperature format (°F/°C) Function 0320 Press s/t to...
Owner's Manual
Page 27
... (no reminder to change UV lamp) Note: Press RESET 1 Reminder after 1 year to cancel the alert Program schedule periods Function 0540 Press s/t to set the number of program periods: Options: 2 Two program periods (Wake, Sleep) 4 Four program periods (Wake, Leave, Return, Sleep) Clock format Function 0640 Press s/t to set the clock display format: Options...
... (no reminder to change UV lamp) Note: Press RESET 1 Reminder after 1 year to cancel the alert Program schedule periods Function 0540 Press s/t to set the number of program periods: Options: 2 Two program periods (Wake, Sleep) 4 Four program periods (Wake, Leave, Return, Sleep) Clock format Function 0640 Press s/t to set the clock display format: Options...
Owner's Manual
Page 29
.... • Check circuit breaker and reset if necessary. • Make sure power switch at the same time • This is following the programmed fan setting. does not respond • Press SYSTEM to set system to Heat. Make sure the temperature is set cooling system higher than the ...Inside temperature. Auto indicates the thermostat is normal operation. Display shows Fan Auto and On or Auto and Circ at heating & cooling system is on . If Auto and On ...
.... • Check circuit breaker and reset if necessary. • Make sure power switch at the same time • This is following the programmed fan setting. does not respond • Press SYSTEM to set system to Heat. Make sure the temperature is set cooling system higher than the ...Inside temperature. Auto indicates the thermostat is normal operation. Display shows Fan Auto and On or Auto and Circ at heating & cooling system is on . If Auto and On ...