Hardware Maintenance Manual
Page 6
... : http://www.ibm.com/support/ The IBM Personal computing solutions page. http://www.ibm.com/pc/ iv Netfinity Server HMM IBM online addresses: The HMM manuals online address is: http://www.ibm.com/pc/us/cdt/hmm.html The IBM Support Page is : http://www.ibm.com/pc/files.html The IBM BBS can be... reached at (919) 517-0001. Lesen Sie alle Sicherheitshinweise, bevor Sie eine Anweisung ausführen. Online support Use the IBM Personal computing solutions (BBS) or the World Wide Web (WWW) to download Diagnostic, BIOS Flash, and Device Driver files. Lea atentamente todas las ...
... : http://www.ibm.com/support/ The IBM Personal computing solutions page. http://www.ibm.com/pc/ iv Netfinity Server HMM IBM online addresses: The HMM manuals online address is: http://www.ibm.com/pc/us/cdt/hmm.html The IBM Support Page is : http://www.ibm.com/pc/files.html The IBM BBS can be... reached at (919) 517-0001. Lesen Sie alle Sicherheitshinweise, bevor Sie eine Anweisung ausführen. Online support Use the IBM Personal computing solutions (BBS) or the World Wide Web (WWW) to download Diagnostic, BIOS Flash, and Device Driver files. Lea atentamente todas las ...
Hardware Maintenance Manual
Page 26
... related configuration information, by accessing the following World Wide Web address: http://www.ibm.com/pc/us/compat/ Jumpers and switches are used to define certain configuration values... with the following standards: Peripheral Component Interconnect (PCI) Industry Standard Architecture (ISA) Small Computer System Interface (SCSI) Accelerated Graphics Port (AGP) You can configure system board functions, ...that comes with the devices for drives that you install. Reading the instructions 18 Netfinity Server HMM Configuration overview You play a key role in how the server allocates ...
... related configuration information, by accessing the following World Wide Web address: http://www.ibm.com/pc/us/compat/ Jumpers and switches are used to define certain configuration values... with the following standards: Peripheral Component Interconnect (PCI) Industry Standard Architecture (ISA) Small Computer System Interface (SCSI) Accelerated Graphics Port (AGP) You can configure system board functions, ...that comes with the devices for drives that you install. Reading the instructions 18 Netfinity Server HMM Configuration overview You play a key role in how the server allocates ...
Hardware Maintenance Manual
Page 53
... the computer will not power-off, do the following for proper installation. Attention These voltages must be checked with the power supply cables connected to the system board or riser card. 1 10 11 Pin Signal 1 3.3 V 2 3.3 V 3 COM 4 5 V 5 COM 6 5 V 7 COM 8 POK 20 Function +3.3 V dc +3.3 V dc Ground +5 V dc Ground +5 V dc Ground Power Good IBM Netfinity 3000 - If...
... the computer will not power-off, do the following for proper installation. Attention These voltages must be checked with the power supply cables connected to the system board or riser card. 1 10 11 Pin Signal 1 3.3 V 2 3.3 V 3 COM 4 5 V 5 COM 6 5 V 7 COM 8 POK 20 Function +3.3 V dc +3.3 V dc Ground +5 V dc Ground +5 V dc Ground Power Good IBM Netfinity 3000 - If...
Hardware Maintenance Manual
Page 64
...following table contains the environmental specifications for the Netfinity 3000 server. Low range: - System on : 8% to 80% Heat Output Approximate heat output in your location might exceed the average values stated because of computers will be substantially below which a large number ...° to 95°F) at altitude 915-2134 m (3000-7000 ft) - Input kilovolt-amperes (kVA) (approximately): - The declared sound power levels indicate an upper limit, below the theoretical maximum. 56 Netfinity Server HMM Maximum configuration (as shipped): 0.70 kVA Power consumption...
...following table contains the environmental specifications for the Netfinity 3000 server. Low range: - System on : 8% to 80% Heat Output Approximate heat output in your location might exceed the average values stated because of computers will be substantially below which a large number ...° to 95°F) at altitude 915-2134 m (3000-7000 ft) - Input kilovolt-amperes (kVA) (approximately): - The declared sound power levels indicate an upper limit, below the theoretical maximum. 56 Netfinity Server HMM Maximum configuration (as shipped): 0.70 kVA Power consumption...
Hardware Maintenance Manual
Page 97
To select and order the correct SCSI cable for the external device on the other computers. Serial ports transfer data asynchronously; The pin-number assignments conform to send 4 Data terminal ready 9 Ring indicator 5 Signal ground Table 2. Serial port...ports (1 and 2). The bits-per second (bps) up to the external SCSI connector, using a SCSI cable. Serial Port Connector Pin-Number Assignments IBM Netfinity 3000 - Both of the serial connectors on the duration of the pauses between characters. they can add more serial ports by installing a serial adapter in ...
To select and order the correct SCSI cable for the external device on the other computers. Serial ports transfer data asynchronously; The pin-number assignments conform to send 4 Data terminal ready 9 Ring indicator 5 Signal ground Table 2. Serial port...ports (1 and 2). The bits-per second (bps) up to the external SCSI connector, using a SCSI cable. Serial Port Connector Pin-Number Assignments IBM Netfinity 3000 - Both of the serial connectors on the duration of the pauses between characters. they can add more serial ports by installing a serial adapter in ...
Hardware Maintenance Manual
Page 112
... small computer system interface (SCSI). SCSI physical unit numbers: When more information.) If you install wide (16-bit) SCSI devices, you connect to view the SCSI IDs of the SCSI devices that comply with only one physical device is 0. Use SCSISelect to the integrated SCSI-2 connector. The Netfinity 3000 server ...SCSI bus at a time, the priority of methods to 8. The SCSI device ID is based on its LUN is connected to http://www.ibm.com/pc/us/netfinity/ on page 49 for each SCSI device that you can set the IDs to a single connector. If you install narrow (8-bit) SCSI...
... small computer system interface (SCSI). SCSI physical unit numbers: When more information.) If you install wide (16-bit) SCSI devices, you connect to view the SCSI IDs of the SCSI devices that comply with only one physical device is 0. Use SCSISelect to the integrated SCSI-2 connector. The Netfinity 3000 server ...SCSI bus at a time, the priority of methods to 8. The SCSI device ID is based on its LUN is connected to http://www.ibm.com/pc/us/netfinity/ on page 49 for each SCSI device that you can set the IDs to a single connector. If you install narrow (8-bit) SCSI...
Hardware Maintenance Manual
Page 139
...damage the microprocessor. Perform the POST/BIOS (flash) update procedure (see http://www.ibm.com/pc/us/netfinity/ on the World Wide Web. Type 8476 131 Notes Read "Safety information" on page 59. IBM Netfinity 3000 - Note If you want to update the server BIOS. For a list of ... telephone numbers. Installing or replacing microprocessors: This section gives the procedure for the server through the World Wide Web and the IBM Personal Computer Company Bulletin Board System (BBS). You can determine whether you select a setting for the frequency switch that is greater than...
...damage the microprocessor. Perform the POST/BIOS (flash) update procedure (see http://www.ibm.com/pc/us/netfinity/ on the World Wide Web. Type 8476 131 Notes Read "Safety information" on page 59. IBM Netfinity 3000 - Note If you want to update the server BIOS. For a list of ... telephone numbers. Installing or replacing microprocessors: This section gives the procedure for the server through the World Wide Web and the IBM Personal Computer Company Bulletin Board System (BBS). You can determine whether you select a setting for the frequency switch that is greater than...
Hardware Maintenance Manual
Page 168
...1. No beep symptoms No Beep/Symptom No Beeps occur after successfully completing POST (The Power-On Status is listed first. Run Setup 2. For IBM devices not supported by pauses (intervals without sound). Beeps 1-2-X 4 Description One beep A pause (or break) Two beeps A pause (or ... the Netfinity 3000 - See the following examples. System Board 160 Netfinity Server HMM Always start with "General Checkout" on page 4. System Board Beep symptoms Beep symptoms are short tones or a series of short tones separated by index, refer to have available when servicing the computer. Use...
...1. No beep symptoms No Beep/Symptom No Beeps occur after successfully completing POST (The Power-On Status is listed first. Run Setup 2. For IBM devices not supported by pauses (intervals without sound). Beeps 1-2-X 4 Description One beep A pause (or break) Two beeps A pause (or ... the Netfinity 3000 - See the following examples. System Board 160 Netfinity Server HMM Always start with "General Checkout" on page 4. System Board Beep symptoms Beep symptoms are short tones or a series of short tones separated by index, refer to have available when servicing the computer. Use...
Hardware Maintenance Manual
Page 171
... 2. Check System Summary menu for memory size change. 2. Processor IBM Netfinity 3000 - Run Setup and verify Configuration 2. Update the Flash BIOS to the latest level 2. System Board 1. System Board 1. Time and Date Set? 2. Memory Module 2. Adapter Memory 2. Power-on external devices first, then power-on computer. 4. System Board 1. Reseat adapters 2. System Board 1. If not...
... 2. Check System Summary menu for memory size change. 2. Processor IBM Netfinity 3000 - Run Setup and verify Configuration 2. Update the Flash BIOS to the latest level 2. System Board 1. System Board 1. Time and Date Set? 2. Memory Module 2. Adapter Memory 2. Power-on external devices first, then power-on computer. 4. System Board 1. Reseat adapters 2. System Board 1. If not...
Hardware Maintenance Manual
Page 172
... Module 3. System Board 1. System Board 3. C2 Security 1. Enter the administrator password 1. Keyboard Cable 4. Keyboard Cable 3. Covers were removed from the computer. 1. Clear Administration password 2. Run Enhanced Diag. Keyboard 2. System Board 164 Netfinity Server HMM POST Error Code/Symptom 168 Alert on LAN are disabled in Configuration/Setup. Run Setup. System Board 1. System...
... Module 3. System Board 1. System Board 3. C2 Security 1. Enter the administrator password 1. Keyboard Cable 4. Keyboard Cable 3. Covers were removed from the computer. 1. Clear Administration password 2. Run Enhanced Diag. Keyboard 2. System Board 164 Netfinity Server HMM POST Error Code/Symptom 168 Alert on LAN are disabled in Configuration/Setup. Run Setup. System Board 1. System...
Hardware Maintenance Manual
Page 199
... 8476 191 M32 TFTP open TFTP connection. M41 BOOTP timeout. M42 No client or server Internet protocol (IP) address. Press Ctrl+Alt+Del to another computer, an error message generated by keystroke. M95 MTFTP timeout. M96 Cannot ARP MTFTP address. Miscellaneous symptoms Symptom CD-ROM drive not working . CD-ROM Drive... TFTP parameter (operation code). M40 BOOTP canceled by keystroke. M91 MTFTP canceled by keystroke. CD-ROM drive tray is locked. FRU/Action 1. CD-ROM Drive IBM Netfinity 3000 -
... 8476 191 M32 TFTP open TFTP connection. M41 BOOTP timeout. M42 No client or server Internet protocol (IP) address. Press Ctrl+Alt+Del to another computer, an error message generated by keystroke. M95 MTFTP timeout. M96 Cannot ARP MTFTP address. Miscellaneous symptoms Symptom CD-ROM drive not working . CD-ROM Drive... TFTP parameter (operation code). M40 BOOTP canceled by keystroke. M91 MTFTP canceled by keystroke. CD-ROM drive tray is locked. FRU/Action 1. CD-ROM Drive IBM Netfinity 3000 -
Hardware Maintenance Manual
Page 203
... Utility as 0 or 255. The server stops running when loading device drivers. Run Diagnostics 2. Check for interrupt conflicts with ISA devices. IBM Netfinity 3000 - Symptom The Ethernet Controller cannot connect to the network. The PCI BIOS is securely attached. 2. The diagnostics completed successfully, but the network...Mbps. Make sure that does not have any PCI slots. Type 8476 195 Make sure that the PCI BIOS will assign another computer that the network cable is not configuring the Ethernet controller or adapter correctly. FRU/Action 1. The PCI BIOS interrupt settings are ...
... Utility as 0 or 255. The server stops running when loading device drivers. Run Diagnostics 2. Check for interrupt conflicts with ISA devices. IBM Netfinity 3000 - Symptom The Ethernet Controller cannot connect to the network. The PCI BIOS is securely attached. 2. The diagnostics completed successfully, but the network...Mbps. Make sure that does not have any PCI slots. Type 8476 195 Make sure that the PCI BIOS will assign another computer that the network cable is not configuring the Ethernet controller or adapter correctly. FRU/Action 1. The PCI BIOS interrupt settings are ...
Hardware Maintenance Manual
Page 206
Power-on the computer) Modem, printer, mouse, or non-IBM devices Each adapter Drives Memory-Module Kits (Minimum requirement = 1 bank of 64 MB DIMMs) Note Minimum operating requirements vary for each time). Remove or disconnect ... the system, and replacing that adapter does not correct the problem, suspect the system board then the processor board(s). 198 Netfinity Server HMM Any external devices Surge suppressor device (on the computer. Undetermined problems You are working correctly, return here and do the following FRUs in the drive startup sequence (IML systems...
Power-on the computer) Modem, printer, mouse, or non-IBM devices Each adapter Drives Memory-Module Kits (Minimum requirement = 1 bank of 64 MB DIMMs) Note Minimum operating requirements vary for each time). Remove or disconnect ... the system, and replacing that adapter does not correct the problem, suspect the system board then the processor board(s). 198 Netfinity Server HMM Any external devices Surge suppressor device (on the computer. Undetermined problems You are working correctly, return here and do the following FRUs in the drive startup sequence (IML systems...
Hardware Maintenance Manual
Page 219
...to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this supplement and the PS/2 Hardware Maintenance Manual (part number ...83G8990, form number S52G-9971-02). and Canada 258 Trademarks 260 © Copyright IBM Corp. 2000 211 Safety information 212 ...
...to help you isolate problems. They are written with the assumption that you have model-specific training on all computers, or that are familiar with the computers, functions, terminology, and service information provided in this supplement and the PS/2 Hardware Maintenance Manual (part number ...83G8990, form number S52G-9971-02). and Canada 258 Trademarks 260 © Copyright IBM Corp. 2000 211 Safety information 212 ...
Hardware Maintenance Manual
Page 220
...eyes. Place removed covers and other people will not trip over it . After service, reinstall all covers correctly before servicing an IBM mobile computer. Before you start the machine, ensure that can stand safely without slipping. 2. Insert the ends of the machines during and ...shields, guards, labels, and ground wires. Safety information The following section contains the safety information that you need to the customer. 212 Netfinity Server HMM Never move suddenly or twist when you can be familiar with a nonconductive clip, approximately 8 centimeters (3 inches) from walk ...
...eyes. Place removed covers and other people will not trip over it . After service, reinstall all covers correctly before servicing an IBM mobile computer. Before you start the machine, ensure that can stand safely without slipping. 2. Insert the ends of the machines during and ...shields, guards, labels, and ground wires. Safety information The following section contains the safety information that you need to the customer. 212 Netfinity Server HMM Never move suddenly or twist when you can be familiar with a nonconductive clip, approximately 8 centimeters (3 inches) from walk ...
Hardware Maintenance Manual
Page 223
...in a checklist. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with the power off the computer. Begin the checks with . Checklist: 1. Check for worn, frayed, or pinched cables. 8. Insulation must not be the appropriate type as... 215 Explosive hazards, such as a damaged CRT face or bulging capacitor Mechanical hazards, such as specified in good condition. Check for any non-IBM alterations. 6. c. The power cord should be frayed or worn. 4. Power-off , and the power cord disconnected. Disconnect the power cord....
...in a checklist. Check that the power-supply cover fasteners (screws or rivets) have not been removed or tampered with the power off the computer. Begin the checks with . Checklist: 1. Check for worn, frayed, or pinched cables. 8. Insulation must not be the appropriate type as... 215 Explosive hazards, such as a damaged CRT face or bulging capacitor Mechanical hazards, such as specified in good condition. Check for any non-IBM alterations. 6. c. The power cord should be frayed or worn. 4. Power-off , and the power cord disconnected. Disconnect the power cord....
Hardware Maintenance Manual
Page 224
...the ac plug on a double-insulated or battery-operated system. Wear a grounded wrist strap against ESD damage by a certified electrician. 216 Netfinity Server HMM The mat is a difference in protective packages until they exceed the requirements noted here. 2. Use the round ground-prong of ... sensitive to protect against ESD damage. - Notes: 1. Use an ESD common ground or reference point when working on ac-operated computers. When handling ESD-sensitive parts: Keep the parts in charge between objects. You can occur when there is especially useful when handling...
...the ac plug on a double-insulated or battery-operated system. Wear a grounded wrist strap against ESD damage by a certified electrician. 216 Netfinity Server HMM The mat is a difference in protective packages until they exceed the requirements noted here. 2. Use the round ground-prong of ... sensitive to protect against ESD damage. - Notes: 1. Use an ESD common ground or reference point when working on ac-operated computers. When handling ESD-sensitive parts: Keep the parts in charge between objects. You can occur when there is especially useful when handling...
Hardware Maintenance Manual
Page 262
Laser compliance statement Some IBM Personal Computer models are also sold separately as options. CAUTION: Use of controls or adjustments or performance of the International Electrotechnical Commission (IEC) 825 and CENELEC EN ... resultar em perigosa exposição à radiação. L'utilizzo di controlli, regolazioni o l'esecuzione di procedure diverse da quelle specificate possono provocare l'esposizione a 254 Netfinity Server HMM CD-ROM drives are equipped from the factory with a CD-ROM drive. When a CD-ROM drive is certified to conform to the requirements...
Laser compliance statement Some IBM Personal Computer models are also sold separately as options. CAUTION: Use of controls or adjustments or performance of the International Electrotechnical Commission (IEC) 825 and CENELEC EN ... resultar em perigosa exposição à radiação. L'utilizzo di controlli, regolazioni o l'esecuzione di procedure diverse da quelle specificate possono provocare l'esposizione a 254 Netfinity Server HMM CD-ROM drives are equipped from the factory with a CD-ROM drive. When a CD-ROM drive is certified to conform to the requirements...
Hardware Maintenance Manual
Page 266
...-547-1283 800-551-2832 Information Bulletin Board Service - IBM Bulletin Board Service - IBM Customer Education Business Unit Customized Operational Services EduQuest (Educational Computers) End User HelpDesk Support IBM Anti-Virus Services IBM Authorized Dealer Referrals IBM Dealer Referral IBM Information Referral Service IBM Service IBM PC HelpCenter and HelpDesk IBM Technical Manuals Multimedia Information Center Multimedia HelpCenter OS/2 Information...
...-547-1283 800-551-2832 Information Bulletin Board Service - IBM Bulletin Board Service - IBM Customer Education Business Unit Customized Operational Services EduQuest (Educational Computers) End User HelpDesk Support IBM Anti-Virus Services IBM Authorized Dealer Referrals IBM Dealer Referral IBM Information Referral Service IBM Service IBM PC HelpCenter and HelpDesk IBM Technical Manuals Multimedia Information Center Multimedia HelpCenter OS/2 Information...