Product Guide
Page 4
... 54 Running the Adaptec SCSISelect Utility 54 When to Run the Adaptec SCSISelect Utility 54 Running the SCSISelect Utility 54 Configuring the Adaptec AIC-7899 SCSI Adapter 55 Running the Promise FastBuild Utility 55 When to Run the Promise FastBuild Utility 56 Running the Promise FastBuild Utility 56 Direct Platform Control... Preparation ...75 Extraction ...76 Updating ...76 Individual Updates...77 BIOS Upgrade Description 77 Firmware Update Utility Description 79 FRU/SDR Load Utility Description 79 iv Intel Server Board SCB2 Product Guide
... 54 Running the Adaptec SCSISelect Utility 54 When to Run the Adaptec SCSISelect Utility 54 Running the SCSISelect Utility 54 Configuring the Adaptec AIC-7899 SCSI Adapter 55 Running the Promise FastBuild Utility 55 When to Run the Promise FastBuild Utility 56 Running the Promise FastBuild Utility 56 Direct Platform Control... Preparation ...75 Extraction ...76 Updating ...76 Individual Updates...77 BIOS Upgrade Description 77 Firmware Update Utility Description 79 FRU/SDR Load Utility Description 79 iv Intel Server Board SCB2 Product Guide
Product Guide
Page 7
...SVGA controller. Third-party or OEM chassis may not provide all of memory in a 2U chassis. 1 Description Server Board Features The SCB2 is available in either SCSI or ATA hard drive interface versions as described in a Socket370 Flip Chip Pin Grid Array (FC-PGA) package. A 1U chassis...2. Table 1. Video Memory 8 MB SDRAM of video memory PCI bus Two PCI riser slots capable of supporting either the 1U Intel® SR1200 or the 2U Intel® SR2200 server chassis. The features listed in Table 2 only reflects usage with either of the following configurations: • 1U...
...SVGA controller. Third-party or OEM chassis may not provide all of memory in a 2U chassis. 1 Description Server Board Features The SCB2 is available in either SCSI or ATA hard drive interface versions as described in a Socket370 Flip Chip Pin Grid Array (FC-PGA) package. A 1U chassis...2. Table 1. Video Memory 8 MB SDRAM of video memory PCI bus Two PCI riser slots capable of supporting either the 1U Intel® SR1200 or the 2U Intel® SR2200 server chassis. The features listed in Table 2 only reflects usage with either of the following configurations: • 1U...
Product Guide
Page 8
...PCI riser slot (low profile) BB. Sys fan 3 connector DD. Server Board Connector and Component Locations 8 Intel Server Board SCB2 Product Guide ICMB connector Y. SCSI connector (SCSI version only) P. Diagnostic LEDs (POST code) U. Floppy drive connector E. 66 MHz/64-bit PCI riser...fan connector D. DIMM slots W. ATA-100 connectors (ATA version only) O. Primary processor socket GG. Figure 1 is a composite view of both SCSI and ATA versions. Sys fan 1 connector C. SSI front panel connector M. Hard Disk Drive LED header Q. USB 3 & 4 header CC....
...PCI riser slot (low profile) BB. Sys fan 3 connector DD. Server Board Connector and Component Locations 8 Intel Server Board SCB2 Product Guide ICMB connector Y. SCSI connector (SCSI version only) P. Diagnostic LEDs (POST code) U. Floppy drive connector E. 66 MHz/64-bit PCI riser...fan connector D. DIMM slots W. ATA-100 connectors (ATA version only) O. Primary processor socket GG. Figure 1 is a composite view of both SCSI and ATA versions. Sys fan 1 connector C. SSI front panel connector M. Hard Disk Drive LED header Q. USB 3 & 4 header CC....
Product Guide
Page 11
... onboard video through the use of the server board includes an embedded Adaptec† AIC-7899W controller providing dual Ultra160 Low Voltage Differential (LVD) SCSI channels. ATA-100 Controller The ATA version of the server board provides an embedded dual channel ATA-100 bus through the BIOS setup menu or...The IDE RAID can be terminated. The onboard device must also be configured as follows: • RAID 0: Striping one end of the bus. Video The SCB2 uses an ATI RAGE XL PCI graphics accelerator with 8 MB of video SDRAM that share a single 32-bit, 33-MHz PCI bus master interface as...
... onboard video through the use of the server board includes an embedded Adaptec† AIC-7899W controller providing dual Ultra160 Low Voltage Differential (LVD) SCSI channels. ATA-100 Controller The ATA version of the server board provides an embedded dual channel ATA-100 bus through the BIOS setup menu or...The IDE RAID can be terminated. The onboard device must also be configured as follows: • RAID 0: Striping one end of the bus. Video The SCB2 uses an ATI RAGE XL PCI graphics accelerator with 8 MB of video SDRAM that share a single 32-bit, 33-MHz PCI bus master interface as...
Product Guide
Page 30
SCSI connector (SCSI server board only) B. USB header J. Fan connectors (system and processor) I AB T A 1 0 0 C D A E T A 6 6 G F H C O M K 1 J U SI B OM11717 Figure 16. SSI front panel connector (see the server board diagram label for pin out) D. Fan module connector (7-pin) H. COM 1 header L. Combined Floppy/Front Panel/IDE connector (For use in an Intel chassis only) 30 Intel Server Board SCB2 Product...
SCSI connector (SCSI server board only) B. USB header J. Fan connectors (system and processor) I AB T A 1 0 0 C D A E T A 6 6 G F H C O M K 1 J U SI B OM11717 Figure 16. SSI front panel connector (see the server board diagram label for pin out) D. Fan module connector (7-pin) H. COM 1 header L. Combined Floppy/Front Panel/IDE connector (For use in an Intel chassis only) 30 Intel Server Board SCB2 Product...
Product Guide
Page 42
...Promise Technology IDE RAID Utility. Configuration Utilities Utility Description and brief procedure BIOS Setup Use for system configuration of the SCSI host adapters and onboard SCSI devices in the system. this option to change your system immediately. Direct Platform Control (DPC) Console Use to...information entered via the DPC console. You can move the CMOS jumper on screen.) (Press anytime after memory check.) 42 Intel Server Board SCB2 Product Guide Display a menu for viewing and configuring server management options, viewing the system event log (SEL), setting boot device...
...Promise Technology IDE RAID Utility. Configuration Utilities Utility Description and brief procedure BIOS Setup Use for system configuration of the SCSI host adapters and onboard SCSI devices in the system. this option to change your system immediately. Direct Platform Control (DPC) Console Use to...information entered via the DPC console. You can move the CMOS jumper on screen.) (Press anytime after memory check.) 42 Intel Server Board SCB2 Product Guide Display a menu for viewing and configuring server management options, viewing the system event log (SEL), setting boot device...
Product Guide
Page 54
... adapter and displays the message Adaptec AIC-7899 SCSI BIOS V x.xxx where x.xxx is the version number of the list. 5. When this time allows you want to boot from boot to 15 devices. 54 Intel Server Board SCB2 Product Guide These changes are saved from , then press the key to move ...to boot. 1. Set the second and third boot devices in the server Running the SCSISelect Utility 1. Permanently Changing the Boot Device Priority You can change SCSI device settings that may conflict with those of other devices in the server • Do a low-level format on the video monitor: 2. or ...
... adapter and displays the message Adaptec AIC-7899 SCSI BIOS V x.xxx where x.xxx is the version number of the list. 5. When this time allows you want to boot from boot to 15 devices. 54 Intel Server Board SCB2 Product Guide These changes are saved from , then press the key to move ...to boot. 1. Set the second and third boot devices in the server Running the SCSISelect Utility 1. Permanently Changing the Boot Device Priority You can change SCSI device settings that may conflict with those of other devices in the server • Do a low-level format on the video monitor: 2. or ...
Product Guide
Page 55
...your selection from the following menu: Exit Menu Feature Option Comment Exit Utility? The Promise ATA-100 host adapter is only found on the SCB2 ATA model only. Select the bus from the following menu: Main Menu Menu Item Options You have an AIC-7899 adapter in your... option F5 Switch between color and monochrome F6 Reset to reboot Press any key to host adapter defaults Configuring the Adaptec AIC-7899 SCSI Adapter The Adaptec AIC-7899 SCSI adapter has two busses. Bus:Device:Channel 01:06:A 01:06:B - This menu allows you finish configuring your system.
...your selection from the following menu: Exit Menu Feature Option Comment Exit Utility? The Promise ATA-100 host adapter is only found on the SCB2 ATA model only. Select the bus from the following menu: Main Menu Menu Item Options You have an AIC-7899 adapter in your... option F5 Switch between color and monochrome F6 Reset to reboot Press any key to host adapter defaults Configuring the Adaptec AIC-7899 SCSI Adapter The Adaptec AIC-7899 SCSI adapter has two busses. Bus:Device:Channel 01:06:A 01:06:B - This menu allows you finish configuring your system.
Product Guide
Page 106
... not touch processor pins, 33 Exit menu, configuring, BIOS Setup, 53 F fan, heat sink, disconnecting, 34, 37, 38 Fast EtherChannel, 13, 14 FEC. E Embedded Legacy SCSI submenu, configuring in BIOS Setup, 47 Embedded NIC submenu, configuring in BIOS Setup, 47 Embedded Video Controller submenu, configuring in BIOS Setup, 47, 48 Emergency..., 95 viewing diagnostic messages, 43 power supply calculating power usage, 101 worksheet, calculating DC power, 102 Power-on Self-Test, See POST, 94, 95 106 Intel Server Board SCB2 Product Guide
... not touch processor pins, 33 Exit menu, configuring, BIOS Setup, 53 F fan, heat sink, disconnecting, 34, 37, 38 Fast EtherChannel, 13, 14 FEC. E Embedded Legacy SCSI submenu, configuring in BIOS Setup, 47 Embedded NIC submenu, configuring in BIOS Setup, 47 Embedded Video Controller submenu, configuring in BIOS Setup, 47, 48 Emergency..., 95 viewing diagnostic messages, 43 power supply calculating power usage, 101 worksheet, calculating DC power, 102 Power-on Self-Test, See POST, 94, 95 106 Intel Server Board SCB2 Product Guide