Owners Manual
Page 1
BEFORE using this product, read this manual and save for future reference. Invacare® Homecare Beds 5411IVC, 5410IVC, 5311IVC, 5310IVC, 5307IVC, 5411LowIVC, 5410LowIVC en User Manual This manual MUST be given to the user of the product.
BEFORE using this product, read this manual and save for future reference. Invacare® Homecare Beds 5411IVC, 5410IVC, 5311IVC, 5310IVC, 5307IVC, 5411LowIVC, 5410LowIVC en User Manual This manual MUST be given to the user of the product.
Owners Manual
Page 3
...Bed Ends 25 4.10 Assembling/Installing/Removing Drive Shaft 26 4.11 Inspecting the Bed 27 4.11.1 Installing/Removing Cable Lock 29 4.11.2 Installing the Manual Crank for Hi/Lo Function . . . . . 29 4.11.3 Installing/Removing the Pendant 30 4.12 Storing the Bed 30 5 Operation 31 ...Operation and Component Overview 31 5.2 Operating Full Electric Bed 33 5.3 Operating the Semi-Electric Bed 34 5.3.1 Using the Emergency Crank 35 5.4 Operating the Manual Bed 36 5.5 Optional Bed Rails 36 6 Maintenance 38 6.1 Service Life 38 6.2 Wear and Tear Items 38 6.3 Cleaning the Bed 39 6.4 ...
...Bed Ends 25 4.10 Assembling/Installing/Removing Drive Shaft 26 4.11 Inspecting the Bed 27 4.11.1 Installing/Removing Cable Lock 29 4.11.2 Installing the Manual Crank for Hi/Lo Function . . . . . 29 4.11.3 Installing/Removing the Pendant 30 4.12 Storing the Bed 30 5 Operation 31 ...Operation and Component Overview 31 5.2 Operating Full Electric Bed 33 5.3 Operating the Semi-Electric Bed 34 5.3.1 Using the Emergency Crank 35 5.4 Operating the Manual Bed 36 5.5 Optional Bed Rails 36 6 Maintenance 38 6.1 Service Life 38 6.2 Wear and Tear Items 38 6.3 Cleaning the Bed 39 6.4 ...
Owners Manual
Page 4
...! - Gives useful tips, recommendations and information for articulation of the signal words. Danger indicates an imminently hazardous situation which could result in property damage. Invacare® Homecare Beds 1 General 1.1 Symbols Signal words are used in this manual and apply to be used in home care and long term care facilities. 4 1114836-H-05
...! - Gives useful tips, recommendations and information for articulation of the signal words. Danger indicates an imminently hazardous situation which could result in property damage. Invacare® Homecare Beds 1 General 1.1 Symbols Signal words are used in this manual and apply to be used in home care and long term care facilities. 4 1114836-H-05
Owners Manual
Page 5
CAUTION CLEANING INSTRUCTIONS See Owner's Manual 1. P/N 1116654 Underside of bed shown. Disinfect and wash all connection ports are not damaged and that all components. 4. Rinse thoroughly with water (maximum temperature 110...
CAUTION CLEANING INSTRUCTIONS See Owner's Manual 1. P/N 1116654 Underside of bed shown. Disinfect and wash all connection ports are not damaged and that all components. 4. Rinse thoroughly with water (maximum temperature 110...
Owners Manual
Page 6
Invacare® Homecare Beds Semi-Electric Single Crank Hi/Lo 5310IVC, 5311IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS TO ENDS HEAD FOOT ADJUSTMENT RANGE DECK BED END COMPONENTS ... in (58.3 cm) ± 2 in 26 ¼ in (66.7 cm) to 33 ¾ in (85.7 cm) Head Spring, Universal Bed Ends, Foot Spring Two Motors Manual Single Crank-Hi/Lo 5307IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS TO ENDS HEAD FOOT ADJUSTMENT RANGE...
Invacare® Homecare Beds Semi-Electric Single Crank Hi/Lo 5310IVC, 5311IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS TO ENDS HEAD FOOT ADJUSTMENT RANGE DECK BED END COMPONENTS ... in (58.3 cm) ± 2 in 26 ¼ in (66.7 cm) to 33 ¾ in (85.7 cm) Head Spring, Universal Bed Ends, Foot Spring Two Motors Manual Single Crank-Hi/Lo 5307IVC SHIPPING WEIGHT WEIGHT CAPACITY OCCUPANT SAFE WORKING LOAD OVERALL LENGTH OVERALL WIDTH SPLIT SPRINGS TO ENDS HEAD FOOT ADJUSTMENT RANGE...
Owners Manual
Page 8
...in death, injury, or damage. - If you are marked accordingly. Set-up and Assembly instructions MUST be performed by Invacare. Use of NON-Invacare bed accessories may cause injury or damage. - DANGER! Do not use of the product with this product or any ...available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as user manuals, service manuals or ...
...in death, injury, or damage. - If you are marked accordingly. Set-up and Assembly instructions MUST be performed by Invacare. Use of NON-Invacare bed accessories may cause injury or damage. - DANGER! Do not use of the product with this product or any ...available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as user manuals, service manuals or ...
Owners Manual
Page 11
... not become entangled and/or severed during normal operation of bed side rails may cause injury or death. Monitor patients with the manual/electric bed. Place the mattress deck in lowest height when unattended. Always leave bed in the flat position when left unattended. ... against the bed frame AND bed side rails to bed height. - When using the Invacare bed and bed rails. Replacement Parts/Accessories DANGER! Follow the manufacturer's instructions. User manuals are available at www.invacare.com or your dealer. - Risk Of Death, Injury, Or Damage Patient entrapment from...
... not become entangled and/or severed during normal operation of bed side rails may cause injury or death. Monitor patients with the manual/electric bed. Place the mattress deck in lowest height when unattended. Always leave bed in the flat position when left unattended. ... against the bed frame AND bed side rails to bed height. - When using the Invacare bed and bed rails. Replacement Parts/Accessories DANGER! Follow the manufacturer's instructions. User manuals are available at www.invacare.com or your dealer. - Risk Of Death, Injury, Or Damage Patient entrapment from...
Owners Manual
Page 13
...can be deformed or broken if excessive side pressure is possible and the mattress should be replaced. 13 The Invacare mattress MUST fit firmly against the bed frame AND bed side rails to entrapment. 1114836-H-05 Safety DANGER! ...- Replacement mattresses and bed side rails with a manual/electric bed, the bed rails DO NOT fall under each bed rail product entry to mattress compression. Visit the FDA website at www.invacare.com or your dealer. - Patient entrapment from ..., and/or bed rail. Use the link located under any weight limitations. Invacare manuals are not interchangeable.
...can be deformed or broken if excessive side pressure is possible and the mattress should be replaced. 13 The Invacare mattress MUST fit firmly against the bed frame AND bed side rails to entrapment. 1114836-H-05 Safety DANGER! ...- Replacement mattresses and bed side rails with a manual/electric bed, the bed rails DO NOT fall under each bed rail product entry to mattress compression. Visit the FDA website at www.invacare.com or your dealer. - Patient entrapment from ..., and/or bed rail. Use the link located under any weight limitations. Invacare manuals are not interchangeable.
Owners Manual
Page 21
..., the motors on the semi-electric (5890IVC and 5891IVC) and full electric (5490IVC and 5491IVC) foot springs as well as the crank handles on the manual foot springs (5770IVC) should be on the left so the center mounting latches C are connected, push the springs into a horizontal (straight) position while keeping the...
..., the motors on the semi-electric (5890IVC and 5891IVC) and full electric (5490IVC and 5491IVC) foot springs as well as the crank handles on the manual foot springs (5770IVC) should be on the left so the center mounting latches C are connected, push the springs into a horizontal (straight) position while keeping the...
Owners Manual
Page 22
... disconnect the head pull tube assembly A from the side frame of the outer pull tube D. 3. Extend the inner pull tube shaft C manually until the spring button "clicks" into the lift arm slot H. Replace the grommet/washer F. b. Connect the pull tube end assembly A to...arm of the head spring as follows: a. Secure with the links B provided. 1. Lift the head spring C away from the clevis pin G. 2. c. Invacare® Homecare Beds 4.5 Assembling the Spring Fabric 4.6 Adjusting and Reconnecting the Head Section Pull Tube 1. Connect the spring fabric A together with hitch pin E....
... disconnect the head pull tube assembly A from the side frame of the outer pull tube D. 3. Extend the inner pull tube shaft C manually until the spring button "clicks" into the lift arm slot H. Replace the grommet/washer F. b. Connect the pull tube end assembly A to...arm of the head spring as follows: a. Secure with the links B provided. 1. Lift the head spring C away from the clevis pin G. 2. c. Invacare® Homecare Beds 4.5 Assembling the Spring Fabric 4.6 Adjusting and Reconnecting the Head Section Pull Tube 1. Connect the spring fabric A together with hitch pin E....
Owners Manual
Page 25
... Risk of Damage The Low Bed Ends are designed to install Low Bed Ends. 25 DO NOT combine low bed end with their respective user manuals. If not used with the bed, contact a qualified dealer. 1114836-H-05 Set-up 1. Always install locking caster in the same location on the... are different from moving on how to be used in pairs. Refer to the bed. - Install casters by pushing DOWN on each other Invacare accessories, ALWAYS verify proper placement of these products to allow for unobstructed and proper use requirements that they will not work properly possibly resulting in...
... Risk of Damage The Low Bed Ends are designed to install Low Bed Ends. 25 DO NOT combine low bed end with their respective user manuals. If not used with the bed, contact a qualified dealer. 1114836-H-05 Set-up 1. Always install locking caster in the same location on the... are different from moving on how to be used in pairs. Refer to the bed. - Install casters by pushing DOWN on each other Invacare accessories, ALWAYS verify proper placement of these products to allow for unobstructed and proper use requirements that they will not work properly possibly resulting in...
Owners Manual
Page 28
... make sure they work correctly. Refer to 4.11.1 Installing/Removing Cable Lock, page 29. 6. Manual Beds 1. WARNING! Inspect the junction box for use. 3. Refer to 5.4 Operating the Manual Bed, page 36. 2. If no damage is found , contact an Invacare Customer Service Representative to report the damaged items and request appropriate replacement parts or...
... make sure they work correctly. Refer to 4.11.1 Installing/Removing Cable Lock, page 29. 6. Manual Beds 1. WARNING! Inspect the junction box for use. 3. Refer to 5.4 Operating the Manual Bed, page 36. 2. If no damage is found , contact an Invacare Customer Service Representative to report the damaged items and request appropriate replacement parts or...
Owners Manual
Page 29
.... Push the cable lock clips into the appropriate cable lock slots A. 2. Unfold the handle G on the junction box D, until they click in place. Connect the manual crank E to the cross pins until it attaches to open the cover. 2. Carefully pull the cable lock F away from the junction box D. 3. Slide the cable... following should be accessible. 3. Set-up and push until the spring F engages the cross pins. 4. Flip the input drive shaft cover up 4.11.2 Installing the Manual Crank for Hi/Lo Function Installing 1.
.... Push the cable lock clips into the appropriate cable lock slots A. 2. Unfold the handle G on the junction box D, until they click in place. Connect the manual crank E to the cross pins until it attaches to open the cover. 2. Carefully pull the cable lock F away from the junction box D. 3. Slide the cable... following should be accessible. 3. Set-up and push until the spring F engages the cross pins. 4. Flip the input drive shaft cover up 4.11.2 Installing the Manual Crank for Hi/Lo Function Installing 1.
Owners Manual
Page 32
...5.3 Operating the Semi-Electric Bed, page 34 . To operate the Semi-Electric bed using the three hand cranks, refer to 5.4 Operating the Manual Bed, page 36. Full electric beds use a six-function pendant for all bed operations. 3. Semi-electric beds use a four-function pendant for...DANGER! If any malfunction is detected. 1114836-H-05 Unplug bed from electrical outlet and contact a qualified technician or Invacare for Hi/Lo bed operation. 4. Risk of operation. 1. Invacare® Homecare Beds Before placing the bed into use, test the bed by operating it through all electrical ...
...5.3 Operating the Semi-Electric Bed, page 34 . To operate the Semi-Electric bed using the three hand cranks, refer to 5.4 Operating the Manual Bed, page 36. Full electric beds use a six-function pendant for all bed operations. 3. Semi-electric beds use a four-function pendant for...DANGER! If any malfunction is detected. 1114836-H-05 Unplug bed from electrical outlet and contact a qualified technician or Invacare for Hi/Lo bed operation. 4. Risk of operation. 1. Invacare® Homecare Beds Before placing the bed into use, test the bed by operating it through all electrical ...
Owners Manual
Page 36
Invacare® Homecare Beds 5.4 Operating the Manual Bed Link Fabric not shown. Before placing the bed into or out of... rails without reading and understanding the Bed Rail Risk Notification Guide that accompanies this manual and is included with hand crank B. 2. DANGER! Use ONLY Invacare rails with Invacare products. - The Bed Rail Risk Notification Guide can also be found at the... half length bed rails: one set at the head end of the bed, and one set at www.invacare.com. Invacare recommends the use , test the bed by operating it through all mechanical hook ups. 36 5.5 Optional Bed...
Invacare® Homecare Beds 5.4 Operating the Manual Bed Link Fabric not shown. Before placing the bed into or out of... rails without reading and understanding the Bed Rail Risk Notification Guide that accompanies this manual and is included with hand crank B. 2. DANGER! Use ONLY Invacare rails with Invacare products. - The Bed Rail Risk Notification Guide can also be found at the... half length bed rails: one set at the head end of the bed, and one set at www.invacare.com. Invacare recommends the use , test the bed by operating it through all mechanical hook ups. 36 5.5 Optional Bed...
Owners Manual
Page 37
... the bed rails. Replacement mattresses and bed side rails with Invacare beds at all times. Fall hazard exists due to incorrect installation of bed. Non-Invacare bed rails are not interchangeable. Non-Invacare mattresses are installed correctly and securely attached to the bed while... the original equipment supplied or specified by the bed frame manufacturer are potentially incompatible with Invacare beds. - To avoid injury, ensure that only Invacare mattresses are used with a manual/electric bed, the bed rails DO NOT fall under any weight limitations. After raising/...
... the bed rails. Replacement mattresses and bed side rails with Invacare beds at all times. Fall hazard exists due to incorrect installation of bed. Non-Invacare bed rails are not interchangeable. Non-Invacare mattresses are installed correctly and securely attached to the bed while... the original equipment supplied or specified by the bed frame manufacturer are potentially incompatible with Invacare beds. - To avoid injury, ensure that only Invacare mattresses are used with a manual/electric bed, the bed rails DO NOT fall under any weight limitations. After raising/...
Owners Manual
Page 38
Invacare® Homecare Beds 6 Maintenance 6.1 Service Life WARNING! This product has an expected lifetime of the ...the table: Wear and Tear Items Hand Pendants Crank Handle Casters-tread wear, brake levers Drive Shafts Invacare reserves the right to the recommended schedule in this manual. See the Warranty that shipped with safety instructions, maintenance intervals and correct use . 6.2 Wear and...components include, but are not limited to the frequency and intensity of use stated in this manual. - The effective bed lifetime can vary according to the items in workmanship.
Invacare® Homecare Beds 6 Maintenance 6.1 Service Life WARNING! This product has an expected lifetime of the ...the table: Wear and Tear Items Hand Pendants Crank Handle Casters-tread wear, brake levers Drive Shafts Invacare reserves the right to the recommended schedule in this manual. See the Warranty that shipped with safety instructions, maintenance intervals and correct use . 6.2 Wear and...components include, but are not limited to the frequency and intensity of use stated in this manual. - The effective bed lifetime can vary according to the items in workmanship.
Owners Manual
Page 39
... on the bed should be damaged from damage or staining, perform the following: - Routinely inspect the gearbox for repair. Contact your dealer or Invacare for grease leakage. Read all guidelines, warnings and cautions before using the electric controls again. All repair and maintenance on the bed. - Inspect... from multiple or excessive cleaning. 39 Risk of Injury or Death To prevent a fall or fire: - If a liquid is spilled in this manual. - Keep the product away from falling or fire. - Clean up the spill and allow the electric bed or the area around the electric bed...
... on the bed should be damaged from damage or staining, perform the following: - Routinely inspect the gearbox for repair. Contact your dealer or Invacare for grease leakage. Read all guidelines, warnings and cautions before using the electric controls again. All repair and maintenance on the bed. - Inspect... from multiple or excessive cleaning. 39 Risk of Injury or Death To prevent a fall or fire: - If a liquid is spilled in this manual. - Keep the product away from falling or fire. - Clean up the spill and allow the electric bed or the area around the electric bed...
Owners Manual
Page 43
... dealer for binding. Drive shaft disconnected. Pull tube. Pressing function on pendant results in place. Bed springs do not move in opposite directions (electrical or manual bed). Drive Shaft connected to junction box Call dealer. Lock Casters. 7 Troubleshooting Troubleshooting 7.1 Troubleshooting Mechanical SYMPTOM Bed does not stay in motion other than that...
... dealer for binding. Drive shaft disconnected. Pull tube. Pressing function on pendant results in place. Bed springs do not move in opposite directions (electrical or manual bed). Drive Shaft connected to junction box Call dealer. Lock Casters. 7 Troubleshooting Troubleshooting 7.1 Troubleshooting Mechanical SYMPTOM Bed does not stay in motion other than that...