Owners Manual
Page 1
Invacare® Reliant™ 450 RHL450-1 Invacare Reliant 450 RPL450-1 Invacare Reliant 600 RPL600-1 Manual/Electric Portable Patient Lift User Manual EN This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
Invacare® Reliant™ 450 RHL450-1 Invacare Reliant 450 RPL450-1 Invacare Reliant 600 RPL600-1 Manual/Electric Portable Patient Lift User Manual EN This manual MUST be given to the user of the product. BEFORE using this product, read this manual and save for future reference.
Owners Manual
Page 3
... Grounding 11 7 Disposal 11 Radio Frequency Interference 11 3 PRODUCT LABELING 12 4 TECHNICAL DATA 13 Patient Lift 13 Full Body, Divided Leg and Toileting Slings 14 Reliant Scale RLS6 14 Part No. 1078987 3 ASSEMBLY 15 Assembling the Patient Lift 15 Unpacking the Patient Lift 15 Assembling the Mast to the Base 16...
... Grounding 11 7 Disposal 11 Radio Frequency Interference 11 3 PRODUCT LABELING 12 4 TECHNICAL DATA 13 Patient Lift 13 Full Body, Divided Leg and Toileting Slings 14 Reliant Scale RLS6 14 Part No. 1078987 3 ASSEMBLY 15 Assembling the Patient Lift 15 Unpacking the Patient Lift 15 Assembling the Mast to the Base 16...
Owners Manual
Page 4
... Base Adjustment 48 Replacing Casters/Forks 48 Replacing Rear Casters 48 Replacing Front Casters 49 Replacing Forks 49 11 ACCESSORIES 50 Reliant Scale RLS6 50 Removing the Swivel Bar 50 Installing the Reliant Scale 52 Operating the Scale 54 Keypad Functions 54 Weighing the Patient 55 Replacing the Battery 56 Calibrating the...
... Base Adjustment 48 Replacing Casters/Forks 48 Replacing Rear Casters 48 Replacing Front Casters 49 Replacing Forks 49 11 ACCESSORIES 50 Reliant Scale RLS6 50 Removing the Swivel Bar 50 Installing the Reliant Scale 52 Operating the Scale 54 Keypad Functions 54 Weighing the Patient 55 Replacing the Battery 56 Calibrating the...
Owners Manual
Page 14
... XL 44.5 N/A 72.3 N/A 43.2 450 TOILETING HEAVY HEAVY DUTY W/O DUTY W/ COMMODE COMMODE R121 R140* R141* L N/A N/A 36 45 45 N/A N/A 7 37 55 55 N/A N/A 13 N/A N/A N/A 450 600 600 4.3 Reliant Scale RLS6 Weight Range: Resolution: Display: Automatic Power Down: Size: Weight: Power: Battery Life: Temperature Range: Up to 600 Lbs. (272.7 Kg) +/- 0.2 Lbs (.1 Kg) Liquid...
... XL 44.5 N/A 72.3 N/A 43.2 450 TOILETING HEAVY HEAVY DUTY W/O DUTY W/ COMMODE COMMODE R121 R140* R141* L N/A N/A 36 45 45 N/A N/A 7 37 55 55 N/A N/A 13 N/A N/A N/A 450 600 600 4.3 Reliant Scale RLS6 Weight Range: Resolution: Display: Automatic Power Down: Size: Weight: Power: Battery Life: Temperature Range: Up to 600 Lbs. (272.7 Kg) +/- 0.2 Lbs (.1 Kg) Liquid...
Owners Manual
Page 50
...pinch guard and washer which secure the swivel bar to the boom mounting bracket. Save the shoulder bolt and locknut to secure the Reliant Scale to FIGURE 11.1. 1. Save the swivel bar pin and the two nylon washers for future use of the swivel bar without first ...when the scale is a compact precision scale system designed specifically for the Invacare Patient Lift System. ƽ WARNING DO NOT install or use this equipment without the scale. 11 ACCESSORIES 11 Accessories 11.1 Reliant Scale RLS6 The Reliant Scale is installed. If you are unable to understand the Warnings, ...
...pinch guard and washer which secure the swivel bar to the boom mounting bracket. Save the shoulder bolt and locknut to secure the Reliant Scale to FIGURE 11.1. 1. Save the swivel bar pin and the two nylon washers for future use of the swivel bar without first ...when the scale is a compact precision scale system designed specifically for the Invacare Patient Lift System. ƽ WARNING DO NOT install or use this equipment without the scale. 11 ACCESSORIES 11 Accessories 11.1 Reliant Scale RLS6 The Reliant Scale is installed. If you are unable to understand the Warnings, ...
Owners Manual
Page 52
...all attaching hardware is tightened securely - Refer to Detail "B" in FIGURE 11.2. 4. Manual/Electric Portable Patient Lift 52 Part No. 1078987 Secure the Reliant Scale to the boom mounting bracket with the mounting holes in the load cell assembly. Refer to the load cell assembly with two nylon washers... through both sides of the Reliant Scale into the boom mounting bracket. Align the mounting holes in the swivel bar pin with a shoulder bolt, two nylon washers and a ...
...all attaching hardware is tightened securely - Refer to Detail "B" in FIGURE 11.2. 4. Manual/Electric Portable Patient Lift 52 Part No. 1078987 Secure the Reliant Scale to the boom mounting bracket with the mounting holes in the load cell assembly. Refer to the load cell assembly with two nylon washers... through both sides of the Reliant Scale into the boom mounting bracket. Align the mounting holes in the swivel bar pin with a shoulder bolt, two nylon washers and a ...
Owners Manual
Page 53
DETAIL "A" Boom Locknut Boom Mounting Bracket Nylon Washer Reliant Scale Reliant Scale Mounting Screw Shoulder Bolt Nylon Washer Nylon Washers Load Cell Assembly FIGURE 11.2 Installing the Reliant Scale 11 ACCESSORIES DETAIL "B" Locknut Swivel Bar Swivel Bar Pin Part No. 1078987 53 Manual/Electric Portable Patient Lift
DETAIL "A" Boom Locknut Boom Mounting Bracket Nylon Washer Reliant Scale Reliant Scale Mounting Screw Shoulder Bolt Nylon Washer Nylon Washers Load Cell Assembly FIGURE 11.2 Installing the Reliant Scale 11 ACCESSORIES DETAIL "B" Locknut Swivel Bar Swivel Bar Pin Part No. 1078987 53 Manual/Electric Portable Patient Lift
Owners Manual
Page 54
... current weight when the key is shown in the lock position. Display Window Operation Keys lb kg ZERO LOCK ON OFF ZERO UNITS LOCK UNLOCK Reliant Scale Model RLS6 CAPACITY 600 LB, 272 KG By DETECTO To Operate: 1. Pressing this key will turn the unit on , pressing the button will apply...
... current weight when the key is shown in the lock position. Display Window Operation Keys lb kg ZERO LOCK ON OFF ZERO UNITS LOCK UNLOCK Reliant Scale Model RLS6 CAPACITY 600 LB, 272 KG By DETECTO To Operate: 1. Pressing this key will turn the unit on , pressing the button will apply...
Owners Manual
Page 55
... page 20. 5. For proper attachment instructions refer to Attaching Slings to the Lift on page 29. For improved accuracy on the 450 and 600 Reliant lifts, attach all sling straps to avoid capturing the weight of the swivel bar. B. The lock function will then be seen in the display box...
... page 20. 5. For proper attachment instructions refer to Attaching Slings to the Lift on page 29. For improved accuracy on the 450 and 600 Reliant lifts, attach all sling straps to avoid capturing the weight of the swivel bar. B. The lock function will then be seen in the display box...
Owners Manual
Page 57
...from the scale and press the LOCK/UNLOCK key. The unit will now be removed from the scale to properly calibrate the Reliant Scale. Press the CAL button located on page 28. 2. Pressing the UNITS key toggles between CAL1 and CAL2. 4. support 200 pounds...below. 1. The display window will show UnLd. 5. B. Part No. 1078987 57 Manual/Electric Portable Patient Lift Calibrating the Reliant Scale 11 ACCESSORIES The Reliant Scale will be loaded and unloaded to check the calibration. 10. CAL2 selects the calibration mode for use with the load...
...from the scale and press the LOCK/UNLOCK key. The unit will now be removed from the scale to properly calibrate the Reliant Scale. Press the CAL button located on page 28. 2. Pressing the UNITS key toggles between CAL1 and CAL2. 4. support 200 pounds...below. 1. The display window will show UnLd. 5. B. Part No. 1078987 57 Manual/Electric Portable Patient Lift Calibrating the Reliant Scale 11 ACCESSORIES The Reliant Scale will be loaded and unloaded to check the calibration. 10. CAL2 selects the calibration mode for use with the load...