NEC P461-AVT - MultiSync - 46" LCD TV Support and Manuals
Get Help and Manuals for this NEC item
This item is in your list!
View All Support Options Below
Free NEC P461-AVT manuals!
Problems with NEC P461-AVT?
Ask a Question
Free NEC P461-AVT manuals!
Problems with NEC P461-AVT?
Ask a Question
Popular NEC P461-AVT Manual Pages
P401 : KT-46UN-CC spec brochure - Page 1
... video wall are supported
46" P461/P461-AVT 52" P521/P521-AVT 55" P551/P551-AVT 70" P701/P701-AVT 40" S401/S401-AVT 46" S461/S461-AVT
X-Rite/GretagMacbeth Eye-One Display V2 X-Rite/GretagMacbeth Eye-One Monitor, Eye-One Pro X-Rite ColorMunki Monaco OptixXR (X-Rite DTP 94) ColorVision/Datacolor Spyder 2 Datacolor Spyder 3
52" S521/S521-AVT
MultiSync is replaced.
• Automatic calibration...
P401 : spec brochure - Page 1
...COMMUNICATION REAL-TIME CLOCK/ROUND-THE-CLOCK SCHEDULING CABLECOMP+™ TECHNOLOGY BUILT-IN TUNER (-AVT MODELS)
www.necdisplay.com The P551's 120 Hz refresh rate reduces typical blur seen ...applications
Expand your display investment, allowing for seamless integration of NEC and third-party components. The NEC P Series, featuring the 40" P401, 46" P461, 52" P521, 55" P551 and 70" P701, provides...
P401 : spec brochure - Page 4
...220-240V
175W
210W
290W
280W
600W Standby Mode
PHYSICAL SPECIFICATIONS Bezel Width (L/R, T/B)
Dimensions (without stand) Gross Weight (with box) VESA Hole Configuration ENVIRONMENTAL CONDITIONS Operating Temperature Operating Humidity ACCESSORIES Included Optional
NEC
Third Party
WARRANTY/SERVICE Limited Warranty
P401
P461
P521
P551
P701
40"
46"
0.46mm
0.53mm
500 cd/m2 / 650 cd/m2...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 5
..." for more details.
6 Command reply The monitor replies to section 5.5 "Commands message" for more details.
4.5 Check code
Header Message Check code Delimiter
Check code is the Block Check Code (BCC) between the Header and the End of the "Set parameter reply" is used for some non-slider controls and some special operations, such as follows...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 12
... Message length is 18 bytes.
Delimiter
Delimiter CR
(12/50)
The monitor replies with current Brightness setting and capability to support this byte is set to change the Brightness setting
Header SOH-'0'-Monitor ID-'0'-'E'-'0'-'A'
Message STX-'0'-'0'-'1'-'0'-'0'-'0'-'5'-'0'-ETX
Check code BCC
Header SOH (01h): Start Of Header '0' (30h): Reserved Monitor ID: Specify the Monitor ID of...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 13
... the Monitor ID which you need to the section 4.5 "Check code" for confirmation. How to read the measurement value of Message
Check code
BCC: Block Check Code Refer to check the Brightness setting. (Recommended) Step 5. No error. '0'-'0' (30h, 30h): Operation code page number is 0. '1'-'0' (31h, 30h): Operation code is 10h (in temperature sensors.
Delimiter CR (0Dh): End...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 14
...ID: Indicates a replying Monitor ID. No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'8' (37h, 38h): Operation code is 78h (in the page 2). '0'-'0' (30h, 30h): This operation is "Set parameter" type. '0'-'0'-'0'-'3' (30h, 30h, 30h, 33h): Number of Header '0' (30h): Reserved '0' (30h): Message receiver is set to the section 4.5 "Check code" for a BCC calculation. Delimiter CR...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 15
...CR
Message STX (02h): Start of selected sensor.
No error. '0'-'2' (30h, 32h): Operation code page number is 2. '7'-'9' (37h, 39h): Operation code is 79h (in the page 2). The controller requests ...Message
(15/50) The monitor replies a temperature of Message '0'-'0' (30h, 30h): Result code. Ex.) When this byte is set to 'A', the replying Monitor ID is '1'.
'D' (44h): Message Type is "Get ...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 18
... Message
Check code BCC: Block Check Code Refer to reply with Asset data. Maximum readout length is 32bytes. Delimiter CR (0Dh): End of packet
8. Asset Data read and write
MultiSync X461UN /X461HB /X431BT /P401 /P461 /P521 /P701 /S401 /S461 /S521 and MULTEOS M401 /M461 /M521 have the area for a BCC calculation.
At first set 20h...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 20
...be ASCII characters strings. No error. 'C'-'0'-'0'-'E' (43h, 30h,...the controller Monitor ID: Indicate a replying Monitor ID Ex.) When this byte is set to 'A', the replying Monitor ID is '1'. 'B' (42h): Message type is "... STX (02h): Start of the Asset data area.
Header
Message
Check code
SOH-'0'-Monitor
STX-'C'-'2'-'1'-'1'-ETX BCC
ID-'0'-'A'-'0'-'6'
Delimiter CR
Header SOH (01h): ...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 40
...
P1: Security Pass code 1st '0'-'0'(30h, 30h): "0" | '0'-'9'(30h, 39h): "9"
P2: Security Pass code 2nd '0'-'0'(30h, 30h): "0" | '0'-'9'(30h, 39h): "9"
P3: Security Pass code 3rd '0'-'0'(30h, 30h): "0" | '0'-'9'(30h, 39h): "9"
P4: Security Pass code 4th '0'-'0'(30h, 30h): "0" | '0'-'9'(30h, 39h): "9"
ETX (03h): End of Header '0' (30h): Reserved '0' (30h): Message receiver is set the condition of...
P401 : RS232 codes for X461UN, X461HB, X431BT, P401, P461, P521, P551, P701, S401, S461 and S521 - Page 49
...: ISF-Night: Each needs an adjustment by side (Full) 0: No mean 1: VGA 2: RGB/HV 3: DVI 4: HDMI (Set only) 5: Video1 6: Video2 7: S-Video 10: TV 12: DVD/HD1 13: Option 14: DVD/HD2 15: Display Port 17... supported option TV tuner. Refer to
the
monitor
instruction
manual. Read only
Read only
Read only
sensor
Carbon Temperature
footprint
(49/50) Item Picture Mode
OP code page 02h
OP code 1Ah...
P461 : installation guide - Page 2
... 40 degC 41 to be covered or closed off at the front of 11
If for design review and
recommendations. P461 Installation Guide
46" LCD Display Ventilation Requirements (all models):
Dimensions below are minimum required for proper ventilation. WALL
NEC Display Solutions of ventilation will need to 104 degF
100mm 4"
WALL
100mm 4"
100mm 4"
NOTE:
The ventilation space...
P461 : installation guide - Page 5
P461 Installation Guide
46" LCD Display
Dimensions with optional speakers and stand:
NEC Display Solutions of 11
Rev 1.2
www.necdisplay.com
P461
Page 5 of America, Inc.
P461 : installation guide - Page 11
... MODE sRGB
HIBRIGHT
STANDARD
CINEMA
SCREEN MODE: NORMAL
FULL
WIDE
ZOOM
AUTO SETUP EXECUTE
FILM MODE
OFF
AUTO
Code Data 01 30 41 30 41 30 43 02 43 32 30 33... 30 30 32 30 30 30 32 03 74 0D
NOTE: Contact your NEC rep for codes not listed.
P461 Installation Guide
46" LCD Display
NEC Display Solutions of 11 Cable Connection:
Communication Protocol:
Interface:
RS-232C
Communication...
NEC P461-AVT Reviews
Do you have an experience with the NEC P461-AVT that you would like to share?
Earn 750 points for your review!
We have not received any reviews for NEC yet.
Earn 750 points for your review!