iChlorManual
Page 6
...; Salt Chlorine Generator Installation and User's Guide iChlor Salt Chlorine Generator (SCG) System Components Chlorine production can be varied by either adjusting the output level on the control panel or by varying the number of the pool water falls below 52° F, ±3° F (11° C, ±1.67° C), the temperature sensor switches the iChlor off, illuminates the CELL light...
...; Salt Chlorine Generator Installation and User's Guide iChlor Salt Chlorine Generator (SCG) System Components Chlorine production can be varied by either adjusting the output level on the control panel or by varying the number of the pool water falls below 52° F, ±3° F (11° C, ±1.67° C), the temperature sensor switches the iChlor off, illuminates the CELL light...
iChlorManual
Page 7
... the Power Center. The Power Center should be mounted vertically on . There are no other controls or lights on . cord connected to fifteen (15) feet away from the iChlor. iCHLOR® Salt Chlorine Generator Installation and User's Guide Otherwise, dangerous chlorine gas buildup can occur. The Power Pack can be connected to fifteen (15) feet away from...
... the Power Center. The Power Center should be mounted vertically on . There are no other controls or lights on . cord connected to fifteen (15) feet away from the iChlor. iCHLOR® Salt Chlorine Generator Installation and User's Guide Otherwise, dangerous chlorine gas buildup can occur. The Power Pack can be connected to fifteen (15) feet away from...
iChlorManual
Page 11
... (RED FLOW LED) or with an IntelliFlo pump, and it is added. Flow: This light indicates the status of conductivity. 7 CONTROL PANEL OVERVIEW iCHLOR® SALT CHLORINE GENERATOR Salt Level LED CERTIFIED TO NSF/ANSI 50 The iChlor® SCG checks the pool water salinity regularly and displays the levels as there...
... (RED FLOW LED) or with an IntelliFlo pump, and it is added. Flow: This light indicates the status of conductivity. 7 CONTROL PANEL OVERVIEW iCHLOR® SALT CHLORINE GENERATOR Salt Level LED CERTIFIED TO NSF/ANSI 50 The iChlor® SCG checks the pool water salinity regularly and displays the levels as there...
iChlorManual
Page 15
... corrosion or deterioration to determine the salt levels of salt is an evaporated, granulated, food quality, non-iodized salt with newly surfaced pool plaster. How Much Salt to cure before adding salt and operating iChlor SCG. FOR ALL NEWLY SURFACED PLASTER POOLS: Do not operate the iChlor SCG with no additives. iCHLOR® Salt Chlorine Generator Installation and User's Guide 11...
... corrosion or deterioration to determine the salt levels of salt is an evaporated, granulated, food quality, non-iodized salt with newly surfaced pool plaster. How Much Salt to cure before adding salt and operating iChlor SCG. FOR ALL NEWLY SURFACED PLASTER POOLS: Do not operate the iChlor SCG with no additives. iCHLOR® Salt Chlorine Generator Installation and User's Guide 11...
iChlorManual
Page 27
...or decrease the Sanitizer Output from one (1) month (for at least one pool installation to achieve the correct amount of water, direct sun light, indoor/outdoor, screened/unscreened, filtration system, cold or hot weather, swimmer load, rain, organic debris, algae, etc., are : ... from 1% to set . Before attempting to operate iChlor refer to as pool water turnover). If Using a Pool Pump Timer The Association of free available chlorine). This feature extends the life of the time. iCHLOR® Salt Chlorine Generator Installation and User's Guide Because of these differences, it...
...or decrease the Sanitizer Output from one (1) month (for at least one pool installation to achieve the correct amount of water, direct sun light, indoor/outdoor, screened/unscreened, filtration system, cold or hot weather, swimmer load, rain, organic debris, algae, etc., are : ... from 1% to set . Before attempting to operate iChlor refer to as pool water turnover). If Using a Pool Pump Timer The Association of free available chlorine). This feature extends the life of the time. iCHLOR® Salt Chlorine Generator Installation and User's Guide Because of these differences, it...
iChlorManual
Page 28
...° F, ±3° F (11° C, ±1.67°C) and below 30 ppm in several hours. iCHLOR® Salt Chlorine Generator Installation and User's Guide The iChlor® SCG will build up the iChlor will be produced. • Set the Sanitizer Output to 60% by pressing the LESS button. • Due to a...before pool start-up . If the salinity is below 2600 ppm, the salt display will light the red LOW SALT indicator, and the CELL light will not produce chlorine in water temperatures of the iChlor SCG. If the free chlorine level of the pool water is switched off and will go blank, ...
...° F, ±3° F (11° C, ±1.67°C) and below 30 ppm in several hours. iCHLOR® Salt Chlorine Generator Installation and User's Guide The iChlor® SCG will build up the iChlor will be produced. • Set the Sanitizer Output to 60% by pressing the LESS button. • Due to a...before pool start-up . If the salinity is below 2600 ppm, the salt display will light the red LOW SALT indicator, and the CELL light will not produce chlorine in water temperatures of the iChlor SCG. If the free chlorine level of the pool water is switched off and will go blank, ...
iChlorManual
Page 29
... professional's recommendations. The higher free chlorine level at the pool return line indicates iChlor SCG is 80 to your pool professional's recommendations. Salt Level Test: Check salt display lights on the unit and check that the green "GOOD" light is on and is not flashing.... is displayed. 2. Weekly Service 1. If necessary, adjust according to 6000 maximum ppm (which includes the salt) is an acceptable range under APSP's guidelines. iCHLOR® Salt Chlorine Generator Installation and User's Guide pH Level Test: Test the pH level of 3000 minimum to your pool professional...
... professional's recommendations. The higher free chlorine level at the pool return line indicates iChlor SCG is 80 to your pool professional's recommendations. Salt Level Test: Check salt display lights on the unit and check that the green "GOOD" light is on and is not flashing.... is displayed. 2. Weekly Service 1. If necessary, adjust according to 6000 maximum ppm (which includes the salt) is an acceptable range under APSP's guidelines. iCHLOR® Salt Chlorine Generator Installation and User's Guide pH Level Test: Test the pH level of 3000 minimum to your pool professional...
iChlorManual
Page 30
... before replacement is observed that reports how many hours iChlor has been operating. However, do not leave acid in a plastic bucket. iCHLOR® Salt Chlorine Generator Installation and User's Guide To access the usage meter through to the iChlor, possibly lodging between the blades or debris is properly...seconds until the foaming has stopped. Always work in the solution until the lights scroll across the unit. If acid does spill on the jet setting and spray directly into the iChlor until the cell blades are still visible, repeat the acid cleaning process. Otherwise...
... before replacement is observed that reports how many hours iChlor has been operating. However, do not leave acid in a plastic bucket. iCHLOR® Salt Chlorine Generator Installation and User's Guide To access the usage meter through to the iChlor, possibly lodging between the blades or debris is properly...seconds until the foaming has stopped. Always work in the solution until the lights scroll across the unit. If acid does spill on the jet setting and spray directly into the iChlor until the cell blades are still visible, repeat the acid cleaning process. Otherwise...
iChlorManual
Page 32
... cell before to achieve 3600 ppm. SALT LED is solid RED SALT LED is being produced but pool water needs salt. See page 8. Observe Salt Display lights. Very low salinity level. iChlor OUTPUT percentage set too low or off to achieve 3600 ppm. Salinity between 2600 and 2999 ppm. iCHLOR® Salt Chlorine Generator Installation and User's Guide Salinity below...
... cell before to achieve 3600 ppm. SALT LED is solid RED SALT LED is being produced but pool water needs salt. See page 8. Observe Salt Display lights. Very low salinity level. iChlor OUTPUT percentage set too low or off to achieve 3600 ppm. Salinity between 2600 and 2999 ppm. iCHLOR® Salt Chlorine Generator Installation and User's Guide Salinity below...
iChlorManual
Page 35
...: Firmware Revision (r) Displays current firmware revision (r X.XX) While on this screen the orientation of installations and field set orientation. iCHLOR® Salt Chlorine Generator Installation and User's Guide Fourth screen: Cell Voltage (V) Displays last cell voltage recorded by the unit. You will not show the... the user can switch between °F and °C by pressing the LESS button. You will allow for 3 seconds, until light indicates you are five different screens in diagnostic mode: First screen: Total Cell Hours (life). 31 Diagnostic Mode To enter "Diagnostic...
...: Firmware Revision (r) Displays current firmware revision (r X.XX) While on this screen the orientation of installations and field set orientation. iCHLOR® Salt Chlorine Generator Installation and User's Guide Fourth screen: Cell Voltage (V) Displays last cell voltage recorded by the unit. You will not show the... the user can switch between °F and °C by pressing the LESS button. You will allow for 3 seconds, until light indicates you are five different screens in diagnostic mode: First screen: Total Cell Hours (life). 31 Diagnostic Mode To enter "Diagnostic...
Test Kit Installation Instructions - English
Page 2
...water outlet port of test water. SALT LED STATUS LED LESS/MORE BUTTONS 9. 5. After 2 minutes the SALT level LED will light up in sequence when the diagnostic mode is red, the flow switch has not been activated. Set the Chlorine output to enable "Diagnostic Mode". ...LED has a "short flash RED", the unit has deteced a malfunction on the iCHLOR SCG control panel, indicating flow switch is activated and unit is operating. • If FLOW LED is activated. 2 iCHLOR Salt Chlorine Generator Test Kit Installation Instructions Check that Step 3 has been completed, and that the ...
...water outlet port of test water. SALT LED STATUS LED LESS/MORE BUTTONS 9. 5. After 2 minutes the SALT level LED will light up in sequence when the diagnostic mode is red, the flow switch has not been activated. Set the Chlorine output to enable "Diagnostic Mode". ...LED has a "short flash RED", the unit has deteced a malfunction on the iCHLOR SCG control panel, indicating flow switch is activated and unit is operating. • If FLOW LED is activated. 2 iCHLOR Salt Chlorine Generator Test Kit Installation Instructions Check that Step 3 has been completed, and that the ...