Brochure
Page 4
... limited tank and parts warranty Power Direct Vent • FVIR compliant • Avoids negative air pressure issues by professionals • Features the Guardian System - engineered to use outside the home • Built-in Condensate Neutralizer - Rheem Water Heating • 101 Bell Road... Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • 1.800.268.6966 Rheem.com PRINTED IN U.S.A. 01/12 WP FORM NO. direct vent • Warrior DVX - e levations • L imited warranty: 12-Year on heat exchanger, 5-Year on parts, ...
... limited tank and parts warranty Power Direct Vent • FVIR compliant • Avoids negative air pressure issues by professionals • Features the Guardian System - engineered to use outside the home • Built-in Condensate Neutralizer - Rheem Water Heating • 101 Bell Road... Ltd./Ltée • 125 Edgeware Road, Unit 1 Brampton, Ontario L6Y 0P5 • 1.800.268.6966 Rheem.com PRINTED IN U.S.A. 01/12 WP FORM NO. direct vent • Warrior DVX - e levations • L imited warranty: 12-Year on heat exchanger, 5-Year on parts, ...
Specifications
Page 1
...or exceed ANSI requirements and have been tested according to D.O.E. F HT. COMBUSTION AIR INLET COMBUSTION EXHAUST (VENT) H HOT WATER CONNECTION H COLD WATER CONNECTION Power Direct Vent Induced Draft 40 to 75-Gallon Capacities Up to the model number. D HT. procedures. Residential Gas WI... NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Power Direct Vent induced draft gas water heater is a perfect choice for tight construction or when indoor air quality is a concern Efficiency ...
...or exceed ANSI requirements and have been tested according to D.O.E. F HT. COMBUSTION AIR INLET COMBUSTION EXHAUST (VENT) H HOT WATER CONNECTION H COLD WATER CONNECTION Power Direct Vent Induced Draft 40 to 75-Gallon Capacities Up to the model number. D HT. procedures. Residential Gas WI... NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Power Direct Vent induced draft gas water heater is a perfect choice for tight construction or when indoor air quality is a concern Efficiency ...
Specifications
Page 2
...Air-Inlet Lengths - In keeping with its policy of pipe. * Use only Rheem 3 inch concentric termination. Residential Gas WI NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Model PDV40 PDV40 PDV40 PDV50 PDV50 PDV50 Model PDV40 PDV40 PDV40 PDV40 PDV50... PDV50 PDV50 Model PDV40 PDV40 PDV40 PDV50 PDV50 Air-Inlet Venting Information for PDV50-65, PDV65 and PDV75 Vent & Combustion Air-Inlet System Diameter (Inches)...
...Air-Inlet Lengths - In keeping with its policy of pipe. * Use only Rheem 3 inch concentric termination. Residential Gas WI NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Model PDV40 PDV40 PDV40 PDV50 PDV50 PDV50 Model PDV40 PDV40 PDV40 PDV40 PDV50... PDV50 PDV50 Model PDV40 PDV40 PDV40 PDV50 PDV50 Air-Inlet Venting Information for PDV50-65, PDV65 and PDV75 Vent & Combustion Air-Inlet System Diameter (Inches)...
Use and Care Manual
Page 11
...at all air CSA B137.6) for combustion is acceptable to an existing vent or chimney - DO NOT drill or punch holes in the plastic pipe or fittings. For Power Direct Vent models listed in the venting tables that do not show venting configurations above 7,700 ft. (2,347 m), contact the water heater ...interchange PVC and PVC (Schedule 40, ASTM-D1785 or CSA CPVC pipe and fittings. B137.3) Vent and combustion air-inlet systems PVC (SDR Series, ASTM-D2241 or CSA must be vented separately from the outside atmosphere and all other appliances. Pressure Testing the Gas Supply System The ...
...at all air CSA B137.6) for combustion is acceptable to an existing vent or chimney - DO NOT drill or punch holes in the plastic pipe or fittings. For Power Direct Vent models listed in the venting tables that do not show venting configurations above 7,700 ft. (2,347 m), contact the water heater ...interchange PVC and PVC (Schedule 40, ASTM-D1785 or CSA CPVC pipe and fittings. B137.3) Vent and combustion air-inlet systems PVC (SDR Series, ASTM-D2241 or CSA must be vented separately from the outside atmosphere and all other appliances. Pressure Testing the Gas Supply System The ...
Use and Care Manual
Page 12
...for signs of sagging or other structural members to dissapate. Connect the vent system piping to any of the conditions above are required for Power Direct Vent Models: 40 Gallon with Inputs of vent pipe connected to be installed horizontally through a wall or vertically through ...supplied with the instructions in . (7.6 cm) diameter pipe and defined previously for the vent and 12 fittings for an existing power direct vent water heater, a thorough inspection of the existing vent and combustion air-inlet systems must be performed prior to the blower assembly using the 2...
...for signs of sagging or other structural members to dissapate. Connect the vent system piping to any of the conditions above are required for Power Direct Vent Models: 40 Gallon with Inputs of vent pipe connected to be installed horizontally through a wall or vertically through ...supplied with the instructions in . (7.6 cm) diameter pipe and defined previously for the vent and 12 fittings for an existing power direct vent water heater, a thorough inspection of the existing vent and combustion air-inlet systems must be performed prior to the blower assembly using the 2...
Use and Care Manual
Page 15
...The minimum and maximum equivalent lengths for the vent and combustion air-inlet systems. Combustion Vent Air-Inlet IMPORTANT: Ensure that all the coupling clamps are shown in Table 2. Maximum and Minimum Vent and Combustion Air-Inlet Lengths For Power Direct Vent Models: 50 Gallon With Inputs of 65,000... water heater to 2.5 feet (0.76 meters) of straight pipe and quantity one (1), 45°, 1/8 standard bend elbow is equivalent to operate. For vent and combustion air-inlet terminals, 4 in. (10.1 cm) diameter, Schedule 40, PVC, 90°, 1/4 standard bend elbows (not supplied) along...
...The minimum and maximum equivalent lengths for the vent and combustion air-inlet systems. Combustion Vent Air-Inlet IMPORTANT: Ensure that all the coupling clamps are shown in Table 2. Maximum and Minimum Vent and Combustion Air-Inlet Lengths For Power Direct Vent Models: 50 Gallon With Inputs of 65,000... water heater to 2.5 feet (0.76 meters) of straight pipe and quantity one (1), 45°, 1/8 standard bend elbow is equivalent to operate. For vent and combustion air-inlet terminals, 4 in. (10.1 cm) diameter, Schedule 40, PVC, 90°, 1/4 standard bend elbows (not supplied) along...
Use and Care Manual
Page 19
... structure or exterior finish of the building D o Not install the vent terminal under the eaves and on the exterior wall, under any other Power Direct Vent model. For 75 Gallon Power Direct Vent Models ONLY: These water heater models are extending out of the vent system. Exhaust Vent Terminal Combustion AirInlet Terminal 19 Support vertical and horizontal lengths of...
... structure or exterior finish of the building D o Not install the vent terminal under the eaves and on the exterior wall, under any other Power Direct Vent model. For 75 Gallon Power Direct Vent Models ONLY: These water heater models are extending out of the vent system. Exhaust Vent Terminal Combustion AirInlet Terminal 19 Support vertical and horizontal lengths of...
Use and Care Manual
Page 20
... Roof Min. 12 in . combustion air-inlet pipes pass through the inlet pipes. connector fitting on any gable, dormer or other Power Direct Vent model. Horizontal lengths of the combustion air-inlet system must not terminate below the combustion air-inlet terminal. per foot (10 mm per... meter). For 75 Gallon Power Direct Vent Models ONLY: These water heater models are supplied with two (2) vent and combustion air-inlet termination restrictors. These restrictors help maintain the efficiency of 1/8 in Table 2. ...
... Roof Min. 12 in . combustion air-inlet pipes pass through the inlet pipes. connector fitting on any gable, dormer or other Power Direct Vent model. Horizontal lengths of the combustion air-inlet system must not terminate below the combustion air-inlet terminal. per foot (10 mm per... meter). For 75 Gallon Power Direct Vent Models ONLY: These water heater models are supplied with two (2) vent and combustion air-inlet termination restrictors. These restrictors help maintain the efficiency of 1/8 in Table 2. ...