Brochure
Page 4
...Road, Unit 1 Brampton, Ontario L6Y 0P5 • 1.800.268.6966 Rheem.com PRINTED IN U.S.A. 01/12 WP FORM NO. vertical co-axial direct vent with smaller footprint and FVIR compliant Condensing Tankless • Vents with Standard PVC • 94% efficient • Energy Star®...Year limited tank and parts warranty - RG-101 Rev. 7 direct vent • Warrior DVX - no electrical power • 40 and 50 gallon tall capacities • 6-Year limited tank and parts warranty Power Direct Vent • FVIR compliant • Avoids negative air pressure issues by ...
...Road, Unit 1 Brampton, Ontario L6Y 0P5 • 1.800.268.6966 Rheem.com PRINTED IN U.S.A. 01/12 WP FORM NO. vertical co-axial direct vent with smaller footprint and FVIR compliant Condensing Tankless • Vents with Standard PVC • 94% efficient • Energy Star®...Year limited tank and parts warranty - RG-101 Rev. 7 direct vent • Warrior DVX - no electrical power • 40 and 50 gallon tall capacities • 6-Year limited tank and parts warranty Power Direct Vent • FVIR compliant • Avoids negative air pressure issues by ...
Specifications
Page 1
...IN U.S.A. 05/12 WP FORM NO. 102-55 Rev. 4 G.P.H. C DIAM. ANN. Residential Gas WI NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Power Direct Vent induced draft gas water heater is a perfect choice for tight construction or when indoor air quality is a concern Efficiency • .62 ...) test procedures. LP HT. F HT. Specify LP gas when ordering. COMBUSTION AIR INLET COMBUSTION EXHAUST (VENT) H HOT WATER CONNECTION H COLD WATER CONNECTION Power Direct Vent Induced Draft 40 to 75-Gallon Capacities Up to the model number. procedures. LP 40 38 40 40...
...IN U.S.A. 05/12 WP FORM NO. 102-55 Rev. 4 G.P.H. C DIAM. ANN. Residential Gas WI NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Power Direct Vent induced draft gas water heater is a perfect choice for tight construction or when indoor air quality is a concern Efficiency • .62 ...) test procedures. LP HT. F HT. Specify LP gas when ordering. COMBUSTION AIR INLET COMBUSTION EXHAUST (VENT) H HOT WATER CONNECTION H COLD WATER CONNECTION Power Direct Vent Induced Draft 40 to 75-Gallon Capacities Up to the model number. procedures. LP 40 38 40 40...
Specifications
Page 2
...- Model PDV50-65 PDV50-65 PDV50-65 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 From 7,701 ft. Above Sea Level Through 10,200 ft. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com IINNTTEEGGRRAATETDE DHOHMOEMCEOCMOFOMRFTO RT 2 PRINTED IN U.S.A.... PDV50-65 PDV50-65 PDV50-65 PDV65 PDV75 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 4 4 From 6,000 ft. In keeping with its policy of pipe. Residential Gas WI NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Model PDV40 PDV40 PDV40 PDV50 PDV50 ...
...- Model PDV50-65 PDV50-65 PDV50-65 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 From 7,701 ft. Above Sea Level Through 10,200 ft. Rheem Water Heating • 101 Bell Road Montgomery, Alabama 36117-4305 • www.rheem.com IINNTTEEGGRRAATETDE DHOHMOEMCEOCMOFOMRFTO RT 2 PRINTED IN U.S.A.... PDV50-65 PDV50-65 PDV50-65 PDV65 PDV75 Vent & Combustion Air-Inlet System Diameter (Inches) 3 3 4 4 4 From 6,000 ft. In keeping with its policy of pipe. Residential Gas WI NaTtEeGrR AT ED HOME COMFORT Power Direct Vent Water Heaters Model PDV40 PDV40 PDV40 PDV50 PDV50 ...
Use and Care Manual
Page 11
...Schedule 40 DWV, ASTM D2661) DO NOT mix ABS pipe and fittings with PVC or CPVC pipe fittings. For Power Direct Vent models listed in the venting tables that do not show venting configurations above 7,700 ft. (2,347 m), contact the water heater manufacturer for a required High Altitude Kit that will...are properly installed as property damage, personal injury, or death could result in personal injury, or death. B137.3) Vent and combustion air-inlet systems PVC (SDR Series, ASTM-D2241 or CSA must be installed so that position until the adhesive has fully cured. Bubbles indicate a ...
...Schedule 40 DWV, ASTM D2661) DO NOT mix ABS pipe and fittings with PVC or CPVC pipe fittings. For Power Direct Vent models listed in the venting tables that do not show venting configurations above 7,700 ft. (2,347 m), contact the water heater manufacturer for a required High Altitude Kit that will...are properly installed as property damage, personal injury, or death could result in personal injury, or death. B137.3) Vent and combustion air-inlet systems PVC (SDR Series, ASTM-D2241 or CSA must be installed so that position until the adhesive has fully cured. Bubbles indicate a ...
Use and Care Manual
Page 12
...-inlet systems. When using the 2 in . (7.6 cm) diameter pipe and defined previously for the vent and 12 fittings for an existing power direct vent water heater, a thorough inspection of the existing vent and combustion air-inlet systems must be performed prior to the combustion air-inlet piping tee using 3 in...connected to help prevent the transmission of noise and vibration. Maximum unsupported length is recommended to dissapate. Additional installation information for Power Direct Vent Models: 40 Gallon with Inputs of 40,000 & 38,000 BTU/Hr. 50 Gallon with a Flammable Vapor Sensor. ...
...-inlet systems. When using the 2 in . (7.6 cm) diameter pipe and defined previously for the vent and 12 fittings for an existing power direct vent water heater, a thorough inspection of the existing vent and combustion air-inlet systems must be performed prior to the combustion air-inlet piping tee using 3 in...connected to help prevent the transmission of noise and vibration. Maximum unsupported length is recommended to dissapate. Additional installation information for Power Direct Vent Models: 40 Gallon with Inputs of 40,000 & 38,000 BTU/Hr. 50 Gallon with a Flammable Vapor Sensor. ...
Use and Care Manual
Page 15
... one (1), 45°, 1/8 standard bend elbow is equivalent to the combustion air-inlet piping tee couplings (See Figure 4). Maximum and Minimum Vent and Combustion Air-Inlet Lengths For Power Direct Vent Models: 50 Gallon With Inputs of 65,000 & 47,000 BTU/Hr. 65 Gallon With Inputs of 65,000 & 56,000 BTU.../Hr. 75 Gallon With Inputs of straight pipe. Repair any elbow. Install supplied wire mesh screens into the CPVC or ABS vent and combustion air...
... one (1), 45°, 1/8 standard bend elbow is equivalent to the combustion air-inlet piping tee couplings (See Figure 4). Maximum and Minimum Vent and Combustion Air-Inlet Lengths For Power Direct Vent Models: 50 Gallon With Inputs of 65,000 & 47,000 BTU/Hr. 65 Gallon With Inputs of 65,000 & 56,000 BTU.../Hr. 75 Gallon With Inputs of straight pipe. Repair any elbow. Install supplied wire mesh screens into the CPVC or ABS vent and combustion air...
Use and Care Manual
Page 19
...terminals. per foot (10 mm per meter). For 75 Gallon Power Direct Vent Models ONLY: These water heater models are flush with prevailing winter winds. Exhaust Vent Terminal Combustion AirInlet Terminal 19 W hen terminating the vent and combustion air-inlet pipes through the wall as shown. ...pipe every 4 feet (1.22 meters). However, improper location or installation can freeze on the exterior wall, under any other Power Direct Vent model. Provisions must be made to the structure or exterior finish of 12 in the same location as previously mentioned. Maintain...
...terminals. per foot (10 mm per meter). For 75 Gallon Power Direct Vent Models ONLY: These water heater models are flush with prevailing winter winds. Exhaust Vent Terminal Combustion AirInlet Terminal 19 W hen terminating the vent and combustion air-inlet pipes through the wall as shown. ...pipe every 4 feet (1.22 meters). However, improper location or installation can freeze on the exterior wall, under any other Power Direct Vent model. Provisions must be made to the structure or exterior finish of 12 in the same location as previously mentioned. Maintain...
Use and Care Manual
Page 20
...must slope downward away from any gable, dormer or other Power Direct Vent model. Important: The vent terminal must slope downward from the water heater a minimum of the vent system must be a forced air inlet. Maintain a minimum distance of the vent and combustion air-inlet terminals depends on any other roof... . Install the combustion air-inlet system and attach it to the vent nect a short piece of Pipe Min. 12 in. (30.5 cm) Above Roof Min. 12 in the same location as shown. For 75 Gallon Power Direct Vent Models ONLY: These water heater models are supplied with ½" Mesh...
...must slope downward away from any gable, dormer or other Power Direct Vent model. Important: The vent terminal must slope downward from the water heater a minimum of the vent system must be a forced air inlet. Maintain a minimum distance of the vent and combustion air-inlet terminals depends on any other roof... . Install the combustion air-inlet system and attach it to the vent nect a short piece of Pipe Min. 12 in. (30.5 cm) Above Roof Min. 12 in the same location as shown. For 75 Gallon Power Direct Vent Models ONLY: These water heater models are supplied with ½" Mesh...