CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 3
... E-6 • LOCATION E-9 • INCLUDED E-9 • PART NAMES E-10 • INSTALL WINDOW PANEL E-12 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-16 • PRE-OPERATION CHECKS E-18 • COOL MODE E-20 • DEHUMIDIFICATION MODE E-21 • FAN MODE E-22 • VENTILATION MODE... 1W9 Canada TEL: (905) 568-7140 E-1 Responsible Party: SHARP ELECTRONICS CORPORATION. Sharp Plaza, Mahwah, New Jersey 07430-2135 TEL: 1-800-BE-SHARP Declaration of Conformity SHARP ROOM AIR CONDITIONER CV-P09LX, CV-P12LX, CV-P10MX This ISM device complies with Part 18 of your new ...
... E-6 • LOCATION E-9 • INCLUDED E-9 • PART NAMES E-10 • INSTALL WINDOW PANEL E-12 • INSTALLATION AND REMOVAL OF EXHAUST HOSE .........E-16 • PRE-OPERATION CHECKS E-18 • COOL MODE E-20 • DEHUMIDIFICATION MODE E-21 • FAN MODE E-22 • VENTILATION MODE... 1W9 Canada TEL: (905) 568-7140 E-1 Responsible Party: SHARP ELECTRONICS CORPORATION. Sharp Plaza, Mahwah, New Jersey 07430-2135 TEL: 1-800-BE-SHARP Declaration of Conformity SHARP ROOM AIR CONDITIONER CV-P09LX, CV-P12LX, CV-P10MX This ISM device complies with Part 18 of your new ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 9
...Ventilate the room periodically during dehumidification mode. Extremely adverse weather may cause water to a grounding plug. Cooling performance may freeze inside the hose, causing water inside the unit to whether the appliance is properly grounded. ENGLISH WARNING ABOUT GROUNDING • Improper use , especially if... wire Tab for the electric current. Water can result in through the openings. • To ensure proper drainage, the drainage hose must have no kinks or be on a differ- Consult a qualified electrician or serviceman if the grounding instructions are not completely ...
...Ventilate the room periodically during dehumidification mode. Extremely adverse weather may cause water to a grounding plug. Cooling performance may freeze inside the hose, causing water inside the unit to whether the appliance is properly grounded. ENGLISH WARNING ABOUT GROUNDING • Improper use , especially if... wire Tab for the electric current. Water can result in through the openings. • To ensure proper drainage, the drainage hose must have no kinks or be on a differ- Consult a qualified electrician or serviceman if the grounding instructions are not completely ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 10
... three minutes for safety. • In the event of air as that blown out will enter the room from outside the room via the exhaust hose while in the unit that keeps the compressor turned off for three minutes for the compressor to its initial settings. • Low temperature operation: Is...
... three minutes for safety. • In the event of air as that blown out will enter the room from outside the room via the exhaust hose while in the unit that keeps the compressor turned off for three minutes for the compressor to its initial settings. • Low temperature operation: Is...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 11
... Grommet (1) Bracket (1) Exhaust cover (1) Window panel (1) Adjustment panel (1) Extension panel (1) Rain guard (2) Insect guard net (1) Foam seal (1) Foam seal (3) Foam seal (1) (adhesive type)A (adhesive type)B Hose clamp (1) Screw (8) (thickness:1/5") Remote control (1) Battery (2) (AAA.R03) (thickness:2/5") Manual (1) SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1. Saw (In the event that the window panel needs...
... Grommet (1) Bracket (1) Exhaust cover (1) Window panel (1) Adjustment panel (1) Extension panel (1) Rain guard (2) Insect guard net (1) Foam seal (1) Foam seal (3) Foam seal (1) (adhesive type)A (adhesive type)B Hose clamp (1) Screw (8) (thickness:1/5") Remote control (1) Battery (2) (AAA.R03) (thickness:2/5") Manual (1) SUGGESTED TOOLS FOR WINDOW PANEL INSTALLATION 1. Saw (In the event that the window panel needs...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 12
... receiver 6 window 7 6 POWER Button 8 7 OPERATION Lamp (red) 9 0 8 TIMER Lamp (orange) 0 9 MEGA COOL Lamp (green) 0 0 Air inlet REAR VIEW q q Exhaust air outlet w w Window exhaust adapter e e Exhaust hose r r Remote control hook t t Air filters y u y Drainage nozzle and stopcock u Power supply cord hooks i Drainpipe nozzle and stopcock i o Power supply cord o p Power plug p a a Casters(4) NOTE: Actual...
... receiver 6 window 7 6 POWER Button 8 7 OPERATION Lamp (red) 9 0 8 TIMER Lamp (orange) 0 9 MEGA COOL Lamp (green) 0 0 Air inlet REAR VIEW q q Exhaust air outlet w w Window exhaust adapter e e Exhaust hose r r Remote control hook t t Air filters y u y Drainage nozzle and stopcock u Power supply cord hooks i Drainpipe nozzle and stopcock i o Power supply cord o p Power plug p a a Casters(4) NOTE: Actual...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 18
...16 three times) until it must be installed or removed in a sliding sash window. Surface of the exhaust hose 1 Attach the window exhaust adapter to the exhaust hose. Insert the two projections on the window panel, and attach the window exhaust adapter. Window exhaust adapter Extend ...Exhaust hose Projection Hole "TOP" The exhaust hose should be twisted or bent. MODE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container DEHUMIDIFICATION with the usage mode....
...16 three times) until it must be installed or removed in a sliding sash window. Surface of the exhaust hose 1 Attach the window exhaust adapter to the exhaust hose. Insert the two projections on the window panel, and attach the window exhaust adapter. Window exhaust adapter Extend ...Exhaust hose Projection Hole "TOP" The exhaust hose should be twisted or bent. MODE COOL, FAN, VENTILATION, DEHUMIDIFICATION with no container DEHUMIDIFICATION with the usage mode....
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 19
ENGLISH Removal of the exhaust hose 1 Remove the window exhaust adapter. Lift up and remove the exhaust hose adapter from the unit. "PUSH" Projection E-17 Pull out and remove the window exhaust adapter by pushing down two "PUSH" markings, and slide and close the exhaust cover in the window panel. 2 Remove the exhaust hose adapter from the unit by pushing down on the two projections.
ENGLISH Removal of the exhaust hose 1 Remove the window exhaust adapter. Lift up and remove the exhaust hose adapter from the unit. "PUSH" Projection E-17 Pull out and remove the window exhaust adapter by pushing down two "PUSH" markings, and slide and close the exhaust cover in the window panel. 2 Remove the exhaust hose adapter from the unit by pushing down on the two projections.
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 22
...;F to 86°F. 1 4 4 Press the FAN button to select COOL mode. Stopcock 1 Press the MODE button to set the de- COOL MODE 1 Install the exhaust hose (See Page16), turn off.
...;F to 86°F. 1 4 4 Press the FAN button to select COOL mode. Stopcock 1 Press the MODE button to set the de- COOL MODE 1 Install the exhaust hose (See Page16), turn off.
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 23
...E-21 DEHUMIDIFICATION MODE ENGLISH In this operation, the water tank inside the unit may be submerged in water. Dehumidification with container 1 Remove the exhaust hose (See Page 17) 2 Turn the drainage nozzle to the OPEN position. 3 Pull the stopcock out from the drainage nozzle. • When the... operation. • The red OPERATION lamp on the unit will turn the drainage nozzle to select DEHUMIDIFICATION mode. Moreover, do not bend the hose at a time. Do not operate in the container and empty as necessary. COOL DEHUM FAN VENT 2 2 Press the power button to empty...
...E-21 DEHUMIDIFICATION MODE ENGLISH In this operation, the water tank inside the unit may be submerged in water. Dehumidification with container 1 Remove the exhaust hose (See Page 17) 2 Turn the drainage nozzle to the OPEN position. 3 Pull the stopcock out from the drainage nozzle. • When the... operation. • The red OPERATION lamp on the unit will turn the drainage nozzle to select DEHUMIDIFICATION mode. Moreover, do not bend the hose at a time. Do not operate in the container and empty as necessary. COOL DEHUM FAN VENT 2 2 Press the power button to empty...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 24
...LOW HIGH 4 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn off . Install the exhaust hose (See Page 16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. 1 Press the MODE ...button to select FAN mode. Press the FAN button to set . Install the exhaust hose (See Page16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. 1 Press the MODE button...
...LOW HIGH 4 TO TURN OFF Press the POWER button again. • The red OPERATION lamp on the unit will turn off . Install the exhaust hose (See Page 16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. 1 Press the MODE ...button to select FAN mode. Press the FAN button to set . Install the exhaust hose (See Page16), turn the drainage nozzle to the CLOSE position, and check the drainage nozzle is covered with the stopcock. 1 Press the MODE button...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 31
... attach the drain grommet to the drainpipe nozzle. Whenever the unit is approximately 41/5 pints. • The OPERATION, TIMER and MEGA COOL Hose lamps will be discharged from the drainpipe nozzle, and completely drain any water within the unit in the following cases. Stopcock 7 Replace the ...stopcock to the hose. "OPEN" position 5 Attach the hose to the drainage nozzle, and secure it with the hose clamp. • Prepare for a long time. 1 Carry out the above procedures from 1 to 5. ...
... attach the drain grommet to the drainpipe nozzle. Whenever the unit is approximately 41/5 pints. • The OPERATION, TIMER and MEGA COOL Hose lamps will be discharged from the drainpipe nozzle, and completely drain any water within the unit in the following cases. Stopcock 7 Replace the ...stopcock to the hose. "OPEN" position 5 Attach the hose to the drainage nozzle, and secure it with the hose clamp. • Prepare for a long time. 1 Carry out the above procedures from 1 to 5. ...
CV-P09LX , CV-P10LC , CV-P10MX , CV-P12LX Operation Manual
Page 33
The water tank inside the unit is operated on . The exhaust hose must be drained. (See page29) • Check the power plug. (See page18) AIR CONDITIONER DOES ...does not take place in the remote control. This is turned on a level floor. E-31 For efficient operation, make the hose as short as possible. If the power was off , and also during cooling operation within 3 minutes of the refrigerant flowing inside... for the first 2 to minimize solar energy heating the room. • Is the exhaust hose too long? This is normal. • An audible gurgling sound may produce an odor.
The water tank inside the unit is operated on . The exhaust hose must be drained. (See page29) • Check the power plug. (See page18) AIR CONDITIONER DOES ...does not take place in the remote control. This is turned on a level floor. E-31 For efficient operation, make the hose as short as possible. If the power was off , and also during cooling operation within 3 minutes of the refrigerant flowing inside... for the first 2 to minimize solar energy heating the room. • Is the exhaust hose too long? This is normal. • An audible gurgling sound may produce an odor.