Popular Campbell Scientific 083E Manual Pages
083E Relative Humidity and Temperature Sensor - Page 1
Model 083E Relative Humidity and Temperature Sensor
6/12
Copyright © 2012 Campbell Scientific, Inc.
083E Relative Humidity and Temperature Sensor - Page 3
... Campbell pricelist or product manual. CAMPBELL EXPRESSLY DISCLAIMS AND EXCLUDES ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Campbell's obligation under normal use and service for installation services performed by Campbell such as programming to customer specifications, electrical connections to products manufactured by Campbell Scientific, Inc. ("Campbell...
083E Relative Humidity and Temperature Sensor - Page 4
... form. The form is available from our web site at the customer's expense. Campbell Scientific reserves the right to refuse service on the outside of the problem, an RMA number will be returned to the customer at www.campbellsci.com/repair. The following contact information is for customers within three days of Product Cleanliness and...
083E Relative Humidity and Temperature Sensor - Page 6
083E Table of Contents
Table
7-1. 083E Sensor Wiring for Example Program 9 8-1. Sensor Resistance 12
ii Model 083E-1-X Temperature vs.
083E Relative Humidity and Temperature Sensor - Page 7
... technicians. Introduction
The 083E is a sensitive instrument. FIGURE 1-1. 083E mounted in association with wind farm power performance measurements on permanent met towers. If repair or calibration is required, refer to damage and miss-calibration. It is particularly susceptible to the customer assistance statement at the head of this manual and contact Campbell Scientific.
• Do not...
083E Relative Humidity and Temperature Sensor - Page 9
...the sensor through the center of the hex plug at the bottom of the 083E
to program other 083E compatible Campbell Scientific dataloggers. 1. Secure sensor cable to mast or crossarm with cable ties.
...used to program the CR1000 datalogger to the connector on the bottom of the 083E. 6. Model 083E Relative Humidity and Temperature Sensor
FIGURE 4-2. 41003-5 radiation shield mounted on New Program....
083E Relative Humidity and Temperature Sensor - Page 10
Model 083E Relative Humidity and Temperature Sensor 2. Select a scan interval.
3. Select 083E Temperature and Relative Humidity Sensor and click the right arrow to add it to the list of sensors to be measured.
4
083E Relative Humidity and Temperature Sensor - Page 13
Model 083E Relative Humidity and Temperature Sensor
6. Sensors not installed in )
7. Locate sensors away from objects at least a distance equal to 122°F) See Section 8.2, Limitations of the objects, and at least 30 m (EPA) from
7 A typical installation is illustrated in diameter. Installation...grow, the natural earth surface.
Specifications
Features: • Relative humidity ...
083E Relative Humidity and Temperature Sensor - Page 14
...) See Section 10, References for a list of sources that discuss temperature and relative humidity sensors and siting.
7.2 Mounting
FIGURE 7-1. 092 mounted in 41003-5 radiation shield
8 Model 083E Relative Humidity and Temperature Sensor large paved areas. Protect sensors from thermal radiation and ensure adequate ventilation.
083E Relative Humidity and Temperature Sensor - Page 15
Model 083E Relative Humidity and Temperature Sensor
7.3 Wiring Instructions
Datalogger Datalogger Channel Channel
083E Pin Number (pin F not used)
A B C
D
E
Wire Color ...Resistor 28430
Jump resistor between SE8 and VX1
Red
Signal temp
SE8
Clear
Shield
VX1
9 TABLE 7-1. 083E Sensor Wiring for Example Program
Wire Color White Green Blue
Black
Cable Label Power 12V
Ground Signal ref...
083E Relative Humidity and Temperature Sensor - Page 16
...service data should cause the relative humidity reading to measure 083E-L Public MetOne_083E_Temp Public MetOne_083E_RH DataTable(Table1,True,-1)
DataInterval(0,10,Min,10) Average(1,MetOne_083E_Temp,FP2,False) Sample(1,MetOne_083E_RH,FP2) EndTable 'Main Program BeginProg Scan (5,Sec,1,0)
'MetOne 083E...blow on the sensor. Model 083E Relative Humidity and Temperature Sensor
'CR1000 program to rise....
083E Relative Humidity and Temperature Sensor - Page 17
Model 083E Relative Humidity and Temperature Sensor
8.2 Limitations of RH Measurements at Below Freezing Temperatures
The relative humidity measurement is limited as follows:
Air Temperature (Deg C) 0 -5 -10 -...
083E Relative Humidity and Temperature Sensor - Page 18
Model 083E Relative Humidity and Temperature Sensor
8.3 Temperature Table
The temperature sensor is a resistive device. TABLE 8-1. ...Table 8-1 at the stated temperatures. A resistance measurement across the red and black leads of the 083E should equal the resistances listed in ohms (Ω)
12 Model 083E-1-X Temperature vs. Sensor Resistance
YSI thermistor bead 44212
Temp ( ° C) -50 -49...
083E Relative Humidity and Temperature Sensor - Page 19
... S. G. Guide to Campbell Scientific for calibration and replacement of State ...maintenance. Soc. WMO, 2008. Maintenance and Troubleshooting
9.1 Maintenance Schedule
The 083E is designed to 212°F, Trans. Amer....Guidance for the calculation of saturation vapor pressure, J. Model 083E Relative Humidity and Temperature Sensor
9. IV, Meteorological Measurements...
Campbell Scientific 083E Reviews
Do you have an experience with the Campbell Scientific 083E that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.
Earn 750 points for your review!