092 Barometric Pressure Sensor - Page 3
... manual....service for installation services performed by Campbell such as programming to customer specifications, electrical connections to modification, misuse, neglect, improper service...specific training, is limited to Campbell. This warranty is in materials and workmanship under this warranty is part of removing, reinstalling, and shipping defective products to repairing or replacing...
092 Barometric Pressure Sensor - Page 4
... completed form must fill out a "Statement of the problem, an RMA number will be issued. If the form ...repair. After an applications engineer determines the nature of Product Cleanliness and Decontamination" form and comply with the requirements specified in countries served by Campbell Scientific, Inc. The form is for our employees. Campbell Scientific reserves the right to refuse service...
092 Barometric Pressure Sensor - Page 5
...Appendices
A. CE Certification C-1
Figures
4-1. 092 installed on a vertical mast 2 B-1. Analog wiring B-1
i Use the PDF reader bookmarks tab for links to the printed version of this document. Quickstart 1
4.1 Installation 1 4.2 Programming with Short Cut 3
5. Specifications 7
7. Cautionary Statements 1
3. Installation 7
7.1 Mounting 7 7.2 Wiring 8 7.3 Programming 8
8. Table of...
092 Barometric Pressure Sensor - Page 6
Connecting the 092 to Campbell Scientific Dataloggers 8 A-1. Dip Switches SW1: Analog Output Voltage Settings A-1 A-2. Dip Switches SW2: Analog Output Pressure Range Settings ......... A-2
ii Table of Contents
Tables
7-1.
092 Barometric Pressure Sensor - Page 7
... 092 Barometric Pressure Sensor
1. Only operate the 092 when the polycarbonate case is not guaranteed beyond the range of the cable. Quickstart
4.1 Installation
Please review Section 7, Installation, for repair or replacement.
• The model number and cable length are received.
4. Initial Inspection
• Upon receipt of 10 to 1100 millibars.
3. Check this information against the...
092 Barometric Pressure Sensor - Page 8
Model 092 Barometric Pressure Sensor
FIGURE 4-1. 092 installed on a vertical mast Individual wire leads connect to the CR1000 datalogger as shown in step 5 of the procedure in Section 7.2, Wiring.
2 A generalized wiring diagram is provided in Section 4.2, Programming with Short Cut.
092 Barometric Pressure Sensor - Page 9
Open Short Cut and click on New Program.
2. Select a scan interval.
3 Model 092 Barometric Pressure Sensor
4.2 Programming with Short Cut
Short Cut Program Generator for Windows can also program other 092-compatible Campbell Scientific dataloggers. 1. Short Cut can be used to program the CR1000 datalogger to measure the 092 as outlined in the following procedure.
092 Barometric Pressure Sensor - Page 10
Select the desired units of measure, or use the default BP_mmHg to hold the barometric pressure measurement. Model 092 Barometric Pressure Sensor 3. Select 092 Barometric Pressure Sensor and click the right arrow in the middle of the page to add it to be measured.
4. Define the name of sensors to the list of the public variable, or use the default mmHg.
4
092 Barometric Pressure Sensor - Page 11
Select the desired output data for this example. Send the program from the PC to the CR1000 datalogger are shown in the Wiring
tab.
6. Click Wiring Diagram for a description of sensor wiring for final storage and click Finish.
7. Sensor connections to the CR1000 datalogger when prompted if a telecommunications link is active. 5 Model 092 Barometric Pressure Sensor 5.
092 Barometric Pressure Sensor - Page 12
...contains an analog-to the MetOne 092, 594, 6633A Barometric Pressure Sensor Manual for storage of the polycarbonate case securely in place. The pressure sensor ...232 and SDI-12 are protected from Campbell Scientific pre-wired for analog output with the following settings:
• Analog Output Voltage: 0 to 5 Vdc • Range: 600 to 1100 ...
Model 092 Barometric Pressure Sensor
5.
092 Barometric Pressure Sensor - Page 13
... pipe with diameter of up to a solar shield. The solar shield mounts by Campbell Scientific, Inc. Model 092 Barometric Pressure Sensor
6. Install the sensor such that it is factory-mounted to 2-inch IPS. Specifications
Features: • The following 092 barometer settings are configurable: o measurement range o data output option / communication option o analog output range
•...
092 Barometric Pressure Sensor - Page 14
Model 092 Barometric Pressure Sensor
7.2 Wiring
southern hemisphere.
Connecting the 092 to Campbell Scientific ...CR500 CR510 Terminal 12V
SE Input
G
G
G
7.3 Programming
The following CR1000 programming example can be used, in whole or in part, if the datalogger is similar with the CR800 and CR3000.
'CR1000 with CRBasic Editor. Programming is being programmed with 092 Barometric ...
092 Barometric Pressure Sensor - Page 15
...:
Met One Instruments 1600 Washington Blvd. The sensor must be required in non-volatile memory at the base of the sintered filter at the factory. Model 092 Barometric Pressure Sensor
'Main Program BeginProg
'Main Scan Scan(5,Sec,1,0)
'Default Datalogger Battery Voltage measurement 'BattV' Battery(BattV) 'Default Wiring Panel Temperature measurement 'PTemp_C...
092 Barometric Pressure Sensor - Page 17
...SW1-1
SW1-2
0-1 Vdc
On
On
0-2 Vdc
On
Off
0-2.5 Vdc
Off
On
0-5 Vdc*
Off*
Off*
*Factory configuration at www.campbellsci.com. Highlighted settings are listed in the Met One 092, 594, 6633A Barometric Pressure Sensor Manual, which is available in TABLE A-1 and TABLE A-2. TABLE A-1.
A-1 Appendix A. Complete information concerning measurement, output, and communications...
092 Barometric Pressure Sensor - Page 18
Hg
LOWER UPPER LOWER UPPER
SWITCH SETTINGS SW2-1 SW2-2 SW2-3 SW2-4
600
800
450
600
17.72 23.62 ON ON ON ON
600
900
450
675
...
900
1100
675
825
26.58 32.48 OFF OFF OFF OFF
1Factory configuration at Campbell Scientific 2Settings with no pressure values are set to either of these combinations,
the analog output will default to the full range of 600 to 1100 mbar.
Dip Switches SW2:...