PVS5120-Series Portable Samplers - Page 4

... is available from our web site at the customer's expense. Campbell Scientific reserves the right to refuse service on the outside of the problem, an RMA number will be either emailed to repair@campbellsci.com or faxed to the customer at www.campbellsci.com/repair. After an application engineer determines the nature of the shipping container...
PVS5120-Series Portable Samplers - Page 11

...PVS5120-series portable samplers use the VSC100 controller that is incorrect for connecting the PVS5120 to the datalogger's 12 V terminal causes problems...UNDERSTAND the Precautions section at the front of this manual. • CAUTION: Damage resulting from a ... input, or Campbell Scientific PakBus® datalogger to remote/external sensors should be run in Campbell Scientific's Short Cut....
PVS5120-Series Portable Samplers - Page 12

...Campbell Scientific about any discrepancies. 4. At sea level, the standard pump takes samples at 1.6 m/s (5.1 ft/s) for horizontal draws of the sampler, inspect the packaging and contents for damage. Once the pre-set... documentation. Overview The PVS5120 series can have set mechanically using the liquid...m/s (7.1 ft/s) at setup. The amount of water taken is set the volume control rod and...
PVS5120-Series Portable Samplers - Page 17

... deploy routine: Automatically sets the purge and vacuum times based on hose length (between 25 to 100 ft) Sampler status/feedback (available after every sample): Bottle number, sample number, response code, sampler battery voltage are returned to 122 °F); electrical components can operate at -40 °C (-40 °F) but Campbell Scientific does not recommend...
PVS5120-Series Portable Samplers - Page 32

... ground (⏚) 7.2.3.2 USB Cable (pn 17648) This USB cable is optional. 22 Drivers for sampler configuration (see Section 6.1, Connecting to the VSC100/Sampler via the Power port on... battery to install before opening Campbell Scientific's DevConfig. PVS5120-Series Portable Samplers TABLE 7-1. NOTE Be sure to wait enough time for the drivers to the sampler via DevConfig (p....
PVS5120-Series Portable Samplers - Page 41

... Date and Time, do not change the default setting, the sampler will be fully installed. c. Click Apply. It is fully installed before attempting to be enabled. 3. Also if you...>450 mL or using a datalogger to 59 minutes) 4. PVS5120-Series Portable Samplers CAUTION FIGURE 8-5. Click on the Time Settings tab. a. Set Sample Chamber-Pressure Relief. Change the Start Date and Time ...
PVS5120-Series Portable Samplers - Page 52

...code ranging from 0 to 8 that represents a different condition (TABLE 8-3). 0 indicates no errors... without stopping (must be manually serviced before the sampler is full...PakBus Example Programs (p. B-4). PVS5120-Series Portable Samplers CR1000 ...set independently. 10 TimeOut Vacuum timeout, in seconds, to determine how long sampler should attempt to collect a sample before triggering an error...
PVS5120-Series Portable Samplers - Page 53

... depending on the purge, vacuum, and sample drop times set up in the datalogger program. The Modbus address must be...Campbell Scientific datalogger via RS-485. 8.2.5.1 Configuring the MD485 1. Push the Program button on Peripheral. B-6)). PVS5120-Series Portable Samplers 8.2.4.5 PakBus Example Instructions Below shows example CRBasic instructions for using an SC12 cable. This instruction...
PVS5120-Series Portable Samplers - Page 57

...Campbell Scientific Datalogger Modbus can be used Gray Ground Connects to one port on the optional water detection probe Yellow Water Sensor Connects to collect any data on the Send New button. The ModbusMaster() CRBasic instruction...and to setup the datalogger...the ModbusMaster() CRBasic instruction multiple times. An...datalogger. The settings/options chosen within the instruction depend on...
PVS5120-Series Portable Samplers - Page 58

... no errors. (Read only.) 3 29 1 40029 & 40030 Batt Returns the sampler's battery voltage just before that the sample is deposited in (1 to prevent overflow). 3 or 16 7 1 40007 & 40008 PurgeTime1 Initial purge time, in each bottle(s). 3 or 16 5 1 40005 & 40006 NeverFull Determines if the sampler loops without stopping (must be manually serviced before the...
PVS5120-Series Portable Samplers - Page 63

... repair is designed to the metering chamber cover. PVS5120-Series Portable Samplers b. Open metering chamber by removing wing nuts and chamber cover. 3. An RMA number and product-safety documents (forms are provided) are required prior to obtain an RMA (Return Materials Authorization) number. Maintenance and Troubleshooting The PVS5120 is needed, first contact a Campbell Scientific...
PVS5120-Series Portable Samplers - Page 66

Check for Help in Troubleshooting a Problem Campbell Scientific application engineers need the following information to help troubleshoot a problem: • Serial and model numbers (serial number indicates whether the sampler is still under warranty) • Your PVS5120 sampler program • Symptoms: What is the sampler doing or not doing? • Whether the red LED on the front panel...
PVS5120-Series Portable Samplers - Page 72

...Errors,true,1000) 'stores the communication errors Sample (3,Result(),FP2) EndTable DataTable (logger_battery,1,1000) 'stores the logger battery voltage for quality control in the public table before opening up the sampler for servicing...) it is set... Code Alias Sampler_status(4) = SamplerBatt 'Sampler battery voltage (V) '***Results returned for download from the PVS5120 webpages. 'PVS5120/...
PVS5120-Series Portable Samplers - Page 74

... following two variables are used to convert the numeric response code value from the PVS5120 webpages. 'PVS5120/VSC100 program communicating via ModBus 'hardware includes MD485 'Important ...a result variable for numeric response code (TABLE 8-3). It will disable the sampler until (for servicing...) it was helpful to include an Autorun parameter as set in devconfig. 'The following program ...
PVS5120-Series Portable Samplers - Page 82

... overflow detected" Response_List(7) = "No sample liquid detected" Response_List(8) = "Arm calibration error" Response_List(9) = "Conductivity rod and Sample tube are array values 23 through 29 in TABLE 8-7. The settings/options chosen within the instruction depend on whether you need to issue the ModbusMaster CRBasic instruction and save the returned values to see if it is done...

Campbell Scientific PVS5120D Reviews

Do you have an experience with the Campbell Scientific PVS5120D that you would like to share?
Earn 750 points for your review!
We have not received any reviews for Campbell Scientific yet.

Popular Campbell Scientific PVS5120D Search Terms

The following term is frequently used to search for Campbell Scientific PVS5120D support:

Ask a New Question
Use the box below to post a new question about Campbell Scientific PVS5120D.
Manuals / Documents
Download any of our Campbell Scientific PVS5120D manuals for free!

We have the following 1 documents available for the Campbell Scientific PVS5120D:
  • PVS5120-Series Portable Samplers
Related Items
View other Campbell Scientific Electronics Accessories:

Points & Prizes
  • You can earn points for nearly everything you do on HelpOwl.com
  • You can trade in those points for gift cards at leading retailers such as Amazon.com and Walmart
  • It's that simple!
See How it Works
Create a Free Account

Campbell Scientific Manuals

Find free Campbell Scientific PVS5120D manuals and user guides available at ManualOwl.com. Try out our unique manual viewer allowing you to interact with manuals from directly within your browser!

Campbell Scientific Reviews

View thousands of Campbell Scientific PVS5120D user reviews and customer ratings available at ReviewOwl.com.

Contact Information

Complete Campbell Scientific customer service contact information including steps to reach representatives, hours of operation, customer support links and more from ContactHelp.com.

Scoreboard Ratings

See detailed Campbell Scientific customer service rankings, employee comments and much more from our sister site.