Installation Guide
Page 20
... J9. Ports 10 and 11 Ports: 6 and 7 Ports 8 and 9 4 and 5 2 and 3 Serial number (on plate) 0 and 1 SODIMM (memory module) BBU (Battery Backup Unit) connector LED connector details J7 is for drives 4, 5, 6, 7 (left to right) For more recent models use Pchip v1.4... 0 through 11 are double- Odd-numbered ports 1 through 10. Figure 1. 12-Port 3ware 9500S-12 Serial ATA RAID Controller Figures 2 and 3 show pchip). 12 3ware 9000 Series Serial ATA RAID Controller Installation Guide LED indicators for individual drives on J8 is the upper. connector stacked connectors. The...
... J9. Ports 10 and 11 Ports: 6 and 7 Ports 8 and 9 4 and 5 2 and 3 Serial number (on plate) 0 and 1 SODIMM (memory module) BBU (Battery Backup Unit) connector LED connector details J7 is for drives 4, 5, 6, 7 (left to right) For more recent models use Pchip v1.4... 0 through 11 are double- Odd-numbered ports 1 through 10. Figure 1. 12-Port 3ware 9500S-12 Serial ATA RAID Controller Figures 2 and 3 show pchip). 12 3ware 9000 Series Serial ATA RAID Controller Installation Guide LED indicators for individual drives on J8 is the upper. connector stacked connectors. The...
Installation Guide
Page 21
... the anode side of each 10-pin connector. Pin 1 is the upper. connector stacked connectors. Figure 2. 8-Port 3ware 9500S-8 Serial ATA RAID Controller, Pchip v1.5 (BBU-compatible) Additional Details About the LED Status Connectors As shown in the lower left-hand corner... two pins of each LED to be connected. Installing a Serial ATA RAID Controller LED indicators for the different controllers. Odd-numbered ports 1 through 6. Ports: 6 and 7 4 and 5 2 and 3 Serial number (on plate) 0 and 1 SODIMM (memory module) BBU (Battery Backup Unit) connector LED connector details J7 is ...
... the anode side of each 10-pin connector. Pin 1 is the upper. connector stacked connectors. Figure 2. 8-Port 3ware 9500S-8 Serial ATA RAID Controller, Pchip v1.5 (BBU-compatible) Additional Details About the LED Status Connectors As shown in the lower left-hand corner... two pins of each LED to be connected. Installing a Serial ATA RAID Controller LED indicators for the different controllers. Odd-numbered ports 1 through 6. Ports: 6 and 7 4 and 5 2 and 3 Serial number (on plate) 0 and 1 SODIMM (memory module) BBU (Battery Backup Unit) connector LED connector details J7 is ...
Installation Guide
Page 23
...memory module) LED connector details J7 is for drives 4, 5, 6, 7 (left to right) J8 is the lower of J9. Odd-numbered ports 1 through 6. Ports: 6 and 7 4 and 5 2 and 3 Serial number (on J7 and J8 are located below even-numbered ports 0 through 7 are unused. I2C Serial ports are double- connector stacked connectors. Figure 3. 8-Port 3ware 9500S...-8 Serial ATA RAID Controller, Pchip v1.4 (Non-BBU Compatible) www...
...memory module) LED connector details J7 is for drives 4, 5, 6, 7 (left to right) J8 is the lower of J9. Odd-numbered ports 1 through 6. Ports: 6 and 7 4 and 5 2 and 3 Serial number (on J7 and J8 are located below even-numbered ports 0 through 7 are unused. I2C Serial ports are double- connector stacked connectors. Figure 3. 8-Port 3ware 9500S...-8 Serial ATA RAID Controller, Pchip v1.4 (Non-BBU Compatible) www...
Installation Guide
Page 24
.... Ports: 2 and 3 0 and 1 Serial number (on plate) SODIMM (memory module) BBU (Battery Backup Unit) connector Figure 4. 4-Port 3ware 9500S-4 Serial ATA RAID Controller To connect serial cables to the controller 1 Take out the serial cables provided with the 3ware SATA RAID controller. 3ware serial controllers are supplied with the connector on the controller, matching the slotted key and carefully mate the connectors...
.... Ports: 2 and 3 0 and 1 Serial number (on plate) SODIMM (memory module) BBU (Battery Backup Unit) connector Figure 4. 4-Port 3ware 9500S-4 Serial ATA RAID Controller To connect serial cables to the controller 1 Take out the serial cables provided with the 3ware SATA RAID controller. 3ware serial controllers are supplied with the connector on the controller, matching the slotted key and carefully mate the connectors...
Installation Guide
Page 27
Ports 8 to 11 Ports 4 to 7 Ports 0 to 3 Serial number (on plate) BBU (Battery Backup Unit) connector SODIMM (memory module) LED connector details J7 is for drives 0, 1, 2, 3 (top to bottom) The last two J8 is for drives 4, 5, 6, 7 (top to bottom) pins on ... Multi-lane Internal Connectors I2C LED indicators for drives 8, 9, 10, 11 (top to bottom) J9 are unused. Figure 5. 12-Port 3ware 9500S-12MI Serial ATA RAID Controller Models 9500S-12MI and 9500S-8MI, have : For use with a backplane that has the InfiniBand 4x connectors (SFF-8470), use the InfiniBand 4x cable, which can...
Ports 8 to 11 Ports 4 to 7 Ports 0 to 3 Serial number (on plate) BBU (Battery Backup Unit) connector SODIMM (memory module) LED connector details J7 is for drives 0, 1, 2, 3 (top to bottom) The last two J8 is for drives 4, 5, 6, 7 (top to bottom) pins on ... Multi-lane Internal Connectors I2C LED indicators for drives 8, 9, 10, 11 (top to bottom) J9 are unused. Figure 5. 12-Port 3ware 9500S-12MI Serial ATA RAID Controller Models 9500S-12MI and 9500S-8MI, have : For use with a backplane that has the InfiniBand 4x connectors (SFF-8470), use the InfiniBand 4x cable, which can...
Installation Guide
Page 47
...F6 cannot bring back previous policy settings; Working with a controller other than a 9000-series controller. they can see the software versions (BIOS, Firmware, monitor), serial number, controller and model number, cache memory size, slot # of the 3ware card, and whether or not BBU-support is highlighted.]... Display context sensitive help F1 or Alt+F1 If you have multiple 3ware Esc controllers in your system, return to starting...
...F6 cannot bring back previous policy settings; Working with a controller other than a 9000-series controller. they can see the software versions (BIOS, Firmware, monitor), serial number, controller and model number, cache memory size, slot # of the 3ware card, and whether or not BBU-support is highlighted.]... Display context sensitive help F1 or Alt+F1 If you have multiple 3ware Esc controllers in your system, return to starting...
Installation Guide
Page 90
Driver Installation Under Linux Note about variables: In the instruction below . 5 Run /sbin/depmod -a 6 Type /sbin/mkinitrd 82 3ware 9000 Series Serial ATA RAID Controller Installation Guide The available module files are using (i.e. 2.6, etc.), replace *** with the appropriate module file for your kernel. If a driver is also...driver is not available for your system, you are : For UP kernels: 3w-9xxx.ko For SMP kernels: 3w-9xxx.smp For BigSMP (high memory) kernels: 3w-9xxx.big 3 If you will need to /lib/modules//modules.dep file 4 Mount the CD-ROM, copy and install the ...
Driver Installation Under Linux Note about variables: In the instruction below . 5 Run /sbin/depmod -a 6 Type /sbin/mkinitrd 82 3ware 9000 Series Serial ATA RAID Controller Installation Guide The available module files are using (i.e. 2.6, etc.), replace *** with the appropriate module file for your kernel. If a driver is also...driver is not available for your system, you are : For UP kernels: 3w-9xxx.ko For SMP kernels: 3w-9xxx.smp For BigSMP (high memory) kernels: 3w-9xxx.big 3 If you will need to /lib/modules//modules.dep file 4 Mount the CD-ROM, copy and install the ...
Installation Guide
Page 107
... in the event of the controller cache memory for optimal performance and not be attached to a 3ware 9000 RAID controller to supply power to 72 hours). This allows the controller to use write-caching for a limited period of time (up to the memory module from components that can... be sure you are sensitive electronic equipment and can be exposed to disks. When installing the BBU on the 3ware RAID controller. www.3ware.com 99 Caution: Both the 3ware RAID controller and the Battery Backup Unit are properly...
... in the event of the controller cache memory for optimal performance and not be attached to a 3ware 9000 RAID controller to supply power to 72 hours). This allows the controller to use write-caching for a limited period of time (up to the memory module from components that can... be sure you are sensitive electronic equipment and can be exposed to disks. When installing the BBU on the 3ware RAID controller. www.3ware.com 99 Caution: Both the 3ware RAID controller and the Battery Backup Unit are properly...
Installation Guide
Page 110
Appendix A. Installing the Battery Backup Unit Installation Instructions 1 For full-height controllers, turn the controller memory side up. 102 3ware 9000 Series Serial ATA RAID Controller Installation Guide Figure 4. Full-height board: bracket unscrews from bottom side of board. Half-height board: bracket unscrews from the PCI bracket 3 For full-height controllers, turn the controller memory-side down on a flat surface. 2 Remove the screws that connect the PCI bracket to the controller and set the bracket aside. Removing the screws from top side of board.
Appendix A. Installing the Battery Backup Unit Installation Instructions 1 For full-height controllers, turn the controller memory side up. 102 3ware 9000 Series Serial ATA RAID Controller Installation Guide Figure 4. Full-height board: bracket unscrews from bottom side of board. Half-height board: bracket unscrews from the PCI bracket 3 For full-height controllers, turn the controller memory-side down on a flat surface. 2 Remove the screws that connect the PCI bracket to the controller and set the bracket aside. Removing the screws from top side of board.
User Guide
Page 30
... 8000- When Auto-verify is disabled, verify is not selected, then you want to be executed when the rebuild completes. 54 3ware 9000 Series Serial ATA RAID Controller User Guide Unit Write Cache You can enable or disable write cache for each unit.3DM lists each unit on the...degrade of the physical hard drives' write cache as well as the controller's memory, depending on the menu bar, and shows you are currently enabled or disabled for 7000- If the rebuild fails and Continue on page 113. 3ware Disk Manager (3DM 2) For additional information, see"Setting Background Task ...
... 8000- When Auto-verify is disabled, verify is not selected, then you want to be executed when the rebuild completes. 54 3ware 9000 Series Serial ATA RAID Controller User Guide Unit Write Cache You can enable or disable write cache for each unit.3DM lists each unit on the...degrade of the physical hard drives' write cache as well as the controller's memory, depending on the menu bar, and shows you are currently enabled or disabled for 7000- If the rebuild fails and Continue on page 113. 3ware Disk Manager (3DM 2) For additional information, see"Setting Background Task ...