Administration Guide
Page 28
... 9600 baud, 8 data bits, hardware flow control on the rear panel that operates as the console port. The following procedure uses HyperTerminal for your session in the Name field. Establishing a Console Connection on the ACE Chapter 1 Setting Up the ACE Establishing a Console Connection on the ACE You establish a direct serial connection between your ACE appliance, see the Cisco Application...
... 9600 baud, 8 data bits, hardware flow control on the rear panel that operates as the console port. The following procedure uses HyperTerminal for your session in the Name field. Establishing a Console Connection on the ACE Chapter 1 Setting Up the ACE Establishing a Console Connection on the ACE You establish a direct serial connection between your ACE appliance, see the Cisco Application...
Administration Guide
Page 34
... To change the default Admin password if you must be able to log in to the ACE only through the console port. See "Using the Setup Script to Enable Connectivity to the ACE Device Manager GUI. Caution For software versions A1(8.0a) and higher, you have not already ... The start-up script is not intended for details. Cisco 4700 Series Application Control Engine Appliance Administration Guide 1-8 OL-11157-01 The ACE has one standard RS-232 serial port found on the ACE" section. Connection requires a terminal configured as 9600 baud, 8 data bits, hardware flow control on, 1 ...
... To change the default Admin password if you must be able to log in to the ACE only through the console port. See "Using the Setup Script to Enable Connectivity to the ACE Device Manager GUI. Caution For software versions A1(8.0a) and higher, you have not already ... The start-up script is not intended for details. Cisco 4700 Series Application Control Engine Appliance Administration Guide 1-8 OL-11157-01 The ACE has one standard RS-232 serial port found on the ACE" section. Connection requires a terminal configured as 9600 baud, 8 data bits, hardware flow control on, 1 ...
Administration Guide
Page 58
... 9600 baud, 8 data bits, 1 stop the current terminal monitoring session, enter: host1/Admin# terminal no parity. The range is 8 data bits. 1-32 Cisco 4700 Series Application Control Engine Appliance Administration Guide OL-11157-01 The default is from the console configuration...terminal monitor...... Use the line console configuration mode command to configure the terminal line settings for accessing the ACE by a console or a virtual terminal. The CLI displays the console configuration mode. To stop bit, no monitor To display the console terminal settings, use the show ...
... 9600 baud, 8 data bits, 1 stop the current terminal monitoring session, enter: host1/Admin# terminal no parity. The range is 8 data bits. 1-32 Cisco 4700 Series Application Control Engine Appliance Administration Guide OL-11157-01 The default is from the console configuration...terminal monitor...... Use the line console configuration mode command to configure the terminal line settings for accessing the ACE by a console or a virtual terminal. The CLI displays the console configuration mode. To stop bit, no monitor To display the console terminal settings, use the show ...
Administration Guide
Page 59
... of the command. For example, to display the configured console settings, enter: host1/Admin# show line console line Console: Speed: 9600 bauds Databits: 8 bits per line. For example, to configure the console line settings for the ACE, enter: host1/Admin# config Enter configuration commands, one ...per byte Stopbits: 1 bit(s) Parity: none OL-11157-01 Cisco 4700 Series ...
... of the command. For example, to display the configured console settings, enter: host1/Admin# show line console line Console: Speed: 9600 bauds Databits: 8 bits per line. For example, to configure the console line settings for the ACE, enter: host1/Admin# config Enter configuration commands, one ...per byte Stopbits: 1 bit(s) Parity: none OL-11157-01 Cisco 4700 Series ...