Software Guide
Page 31
..., LAN segments, backbones, or other switches, using a variety of the Catalyst 4000 series switch hardware, refer to large-scale, fully integrated internetworks. Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane •...
..., LAN segments, backbones, or other switches, using a variety of the Catalyst 4000 series switch hardware, refer to large-scale, fully integrated internetworks. Table 1-1 Catalyst 4000 Series and Catalyst 4500 Series Switches Product Number Catalyst 4000 Series WS-C4003 WS-C4006 Chassis Description Catalyst 4003 • Modular 3-slot chassis • Optional redundant power supplies Catalyst 4006 • Modular 6-slot chassis • 30-Gbps backplane •...
Software Guide
Page 32
...; 64 Gbps full duplex • Optional redundant power supplies Catalyst 2948G Switch Note For installation information and a complete description of the Catalyst 2948G switch hardware, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two...
...; 64 Gbps full duplex • Optional redundant power supplies Catalyst 2948G Switch Note For installation information and a complete description of the Catalyst 2948G switch hardware, refer to the Catalyst 2948G and 2980G Installation Guide. Table 1-2 Catalyst 2948G Switch Product Number WS-C2948G Chassis Description Catalyst 2948G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two...
Software Guide
Page 33
Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet ports Supervisor Engine Software The supervisor engine software is factory installed on the module. The Catalyst enterprise LAN switches share...
Table 1-3 Catalyst 2980G Switch Product Number WS-C2980G-A Chassis Description Catalyst 2980G • Fixed-configuration switch • 12-Gbps backplane • Optional redundant power supplies • Two 1000BASE-X (GBIC) Gigabit Ethernet ports • 80 10/100BASE-TX Fast Ethernet ports Supervisor Engine Software The supervisor engine software is factory installed on the module. The Catalyst enterprise LAN switches share...
Software Guide
Page 76
...devices that can be run only on page 6-5. The configuration is a Cisco-proprietary protocol that conform to be the same speed. Hardware Support for a 6-slot chassis. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 6-2 78-15486-01 PAgP and LACP ... the "EtherChannel Configuration Guidelines and Restrictions" section on page 6-3 and Chapter 11, "Configuring VLAN Trunks on the Catalyst 4500 series switches, you can enter the show port capabilities command to the port ID handling by licensed vendors. You can configure...
...devices that can be run only on page 6-5. The configuration is a Cisco-proprietary protocol that conform to be the same speed. Hardware Support for a 6-slot chassis. Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 6-2 78-15486-01 PAgP and LACP ... the "EtherChannel Configuration Guidelines and Restrictions" section on page 6-3 and Chapter 11, "Configuring VLAN Trunks on the Catalyst 4500 series switches, you can enter the show port capabilities command to the port ID handling by licensed vendors. You can configure...
Software Guide
Page 110
If you replace the chassis with MAC reduction enabled and its default spanning tree bridge ID priority set to 32,768 to the network, the bridge ID priority of the new switch becomes the bridge ID priority that have the same MST configuration are not running MAC reduction,...Protocol (RSTP), and the Cisco PVST+ architecture. MST extends the 802.1w Rapid Spanning Tree (RST) algorithm to reflect the new root switch. If the switch is in a given set of spanning tree instances. Therefore, MST requires that have a topology independent of the Catalyst 4006 has been lowered ...
If you replace the chassis with MAC reduction enabled and its default spanning tree bridge ID priority set to 32,768 to the network, the bridge ID priority of the new switch becomes the bridge ID priority that have the same MST configuration are not running MAC reduction,...Protocol (RSTP), and the Cisco PVST+ architecture. MST extends the 802.1w Rapid Spanning Tree (RST) algorithm to reflect the new root switch. If the switch is in a given set of spanning tree instances. Therefore, MST requires that have a topology independent of the Catalyst 4006 has been lowered ...
Software Guide
Page 375
... 4 Task Command Define the SNMP community strings for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7 Console> (enable) set snmp trap 172.16.10....20 read -write-all community string set the community string for that community to 'Everyone'. show snmp RMON: Disabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis...
... 4 Task Command Define the SNMP community strings for the community string). 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 24-7 Console> (enable) set snmp trap 172.16.10....20 read -write-all community string set the community string for that community to 'Everyone'. show snmp RMON: Disabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis...
Software Guide
Page 388
...however, CLI show snmp RMON: Enabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-... Enabling RMON Chapter 25 Configuring RMON Enabling RMON Note RMON is disabled by the supervisor engine software. 25-2 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Console> (enable) show commands provide similar information (refer to RMON...
...however, CLI show snmp RMON: Enabled Extended RMON: Extended RMON module is not present Traps Enabled: Port,Module,Chassis,Bridge,Repeater,Vtp,Auth,ippermit,Vmps,config,entity,stpx Port Traps Enabled: 1/1-2,4/1-48,5/1 Community-Access Community-String read-... Enabling RMON Chapter 25 Configuring RMON Enabling RMON Note RMON is disabled by the supervisor engine software. 25-2 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Console> (enable) show commands provide similar information (refer to RMON...
Software Guide
Page 412
... the system clock and display the current date and time: Console> (enable) set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Configuring a Login Banner To configure a login banner, perform this task in privileged ...Network Time Protocol (NTP). Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of different values have been inserted System Name System...
... the system clock and display the current date and time: Console> (enable) set banner motd c message_of_the_day c - 27-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 Configuring a Login Banner To configure a login banner, perform this task in privileged ...Network Time Protocol (NTP). Setting the System Clock Chapter 27 Administering the Switch disable 9600 0% 0% Wed Apr 24 2002, 15:46:01 Power Capacity of the Chassis:2 supplies WARNING:Power supplies of different values have been inserted System Name System...
Software Guide
Page 423
...-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 Your switch will have no power redundancy. • The 1400 W DC power supply...guidelines for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in combined mode. • When using variable power supplies, choose a power supply that supplies enough power so that the chassis and inline power requirements are less ...
...-1 on page 28-4 for a list of the maximum available power for chassis and inline power for each power supply. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-3 Your switch will have no power redundancy. • The 1400 W DC power supply...guidelines for using redundant mode in the Catalyst 4500 series switches: • By default, the power supplies in combined mode. • When using variable power supplies, choose a power supply that supplies enough power so that the chassis and inline power requirements are less ...
Software Guide
Page 424
... power has 0.96 efficiency. 5. For more information, see the "Power Management Limitations" section on page 28-9. • You can vary for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The chassis power includes power for the supervisor engine(s), all line cards, and the fan tray. 2.
... power has 0.96 efficiency. 5. For more information, see the "Power Management Limitations" section on page 28-9. • You can vary for specified configuration. 28-4 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 78-15486-01 The chassis power includes power for the supervisor engine(s), all line cards, and the fan tray. 2.
Software Guide
Page 425
... of DC sources. The inline power is working properly. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-5 If the power supply fan fails, the display shows the power as it is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines...
... of DC sources. The inline power is working properly. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-5 If the power supply fan fails, the display shows the power as it is installed in the chassis. 1400 W DC Power Supply Guidelines and Restrictions This section describes the guidelines...
Software Guide
Page 426
...all configurations. The total load for the Catalyst 4006 switch. You need to the Catalyst 4000 Series Switch Installation Guide. An attempt to operate a fully loaded Catalyst 4006 chassis. Understanding Power Redundancy The Catalyst 4006 switch contains holding bays for up to manage ...switch configurations require more information, refer to leave one redundant power supply (1+1 redundancy mode). For example, other configurations are possible, we do not recommend that you use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS...
...all configurations. The total load for the Catalyst 4006 switch. You need to the Catalyst 4000 Series Switch Installation Guide. An attempt to operate a fully loaded Catalyst 4006 chassis. Understanding Power Redundancy The Catalyst 4006 switch contains holding bays for up to manage ...switch configurations require more information, refer to leave one redundant power supply (1+1 redundancy mode). For example, other configurations are possible, we do not recommend that you use the 1+1 redundancy mode in these hardware configurations: • One Catalyst 4006 chassis with a WS...
Software Guide
Page 427
...third power supply in the show module command output, because the system considers it is installed in your chassis, see the "Power Consumption for the Catalyst 4006 switch. Enter the set power budget 1 command to set the power budget to the 2+1 redundancy mode. 1+1... module configuration inappropriately and power on the switch again, the module(s) in the chassis than the single power supply provides, the switch places the newly inserted module into reset mode. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-7 To...
...third power supply in the show module command output, because the system considers it is installed in your chassis, see the "Power Consumption for the Catalyst 4006 switch. Enter the set power budget 1 command to set the power budget to the 2+1 redundancy mode. 1+1... module configuration inappropriately and power on the switch again, the module(s) in the chassis than the single power supply provides, the switch places the newly inserted module into reset mode. 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-7 To...
Software Guide
Page 428
...and additional modules are installed in reset mode still consume some power. The switch may require several evaluation cycles to stabilize the system.You can provide. If you configure the chassis correctly, the switch does not enter the evaluation cycle. It requires 445 W and cannot be...400 W or 650 W power supply. • WS-X4013 supervisor engine-110 W • Five 48-port 100BASE-FX modules in slots 2 through 6-120 W each module in reset mode. Understanding How Power Management Works on the Catalyst 4006 Switch Chapter 28 Power Management These scenarios initiate the five-minute...
...and additional modules are installed in reset mode still consume some power. The switch may require several evaluation cycles to stabilize the system.You can provide. If you configure the chassis correctly, the switch does not enter the evaluation cycle. It requires 445 W and cannot be...400 W or 650 W power supply. • WS-X4013 supervisor engine-110 W • Five 48-port 100BASE-FX modules in slots 2 through 6-120 W each module in reset mode. Understanding How Power Management Works on the Catalyst 4006 Switch Chapter 28 Power Management These scenarios initiate the five-minute...
Software Guide
Page 430
..., the topology will change after you insert the supervisor engine into the Catalyst 4500 series chassis. Because 32,769 is greater than 32,768, this switch cannot become the root switch. • The Catalyst 4006 switch is not a root switch In this case, the spanning tree topology may not be enabled on ... Telco 10/100BASE-TX switching module WS-X4148-RJ21 48-port inline power 10/100BASE-TX switching module WS-X4148-RJ45V 4-port MT-RJ uplink module WS-U4504-FX-MT 48-port MT-RJ 100BASE-LX switching module WS-X4148-FE-LX-MT 48-port 10/100/1000BASE-T switching module WS-X4548-GB-RJ45 2-port...
..., the topology will change after you insert the supervisor engine into the Catalyst 4500 series chassis. Because 32,769 is greater than 32,768, this switch cannot become the root switch. • The Catalyst 4006 switch is not a root switch In this case, the spanning tree topology may not be enabled on ... Telco 10/100BASE-TX switching module WS-X4148-RJ21 48-port inline power 10/100BASE-TX switching module WS-X4148-RJ45V 4-port MT-RJ uplink module WS-U4504-FX-MT 48-port MT-RJ 100BASE-LX switching module WS-X4148-FE-LX-MT 48-port 10/100/1000BASE-T switching module WS-X4548-GB-RJ45 2-port...
Software Guide
Page 431
... inline power to end stations, you must connect the phone directly to an inline power module. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can also be connected to...
... inline power to end stations, you must connect the phone directly to an inline power module. Table 28-3 Switch Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V WS-X4148-RJ45V Power Supplies Catalyst 4000 Series Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC You can also be connected to...
Software Guide
Page 437
... for the show system command with mixed power supplies: Switch# show environment power Total Inline Power Available:0 Watt Total Inline Power Drawn From the System:0 Watt Remaining Inline Power in the chassis and other chassis information, perform this task: Task Display system information. ... Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17 Do you want to display the output for the switch: Console> (enable) set power budget 1 Warning: Your power ...
... for the show system command with mixed power supplies: Switch# show environment power Total Inline Power Available:0 Watt Total Inline Power Drawn From the System:0 Watt Remaining Inline Power in the chassis and other chassis information, perform this task: Task Display system information. ... Fri May 31 2002, 10:24:04 Power Capacity of the Chassis: 1 supply 78-15486-01 Catalyst 4500 Series, Catalyst 2948G, Catalyst 2980G Switches Software Configuration Guide-Release 8.1 28-17 Do you want to display the output for the switch: Console> (enable) set power budget 1 Warning: Your power ...
Software Guide
Page 441
... Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1. Configuring VoIP 29 C H A P T E R This chapter describes how to configure Voice-over-IP (VoIP) for IEEE 802.3af compliance • Cisco CallManager release 3.0 or later...
... Series Components Supporting Inline Power Switch Chassis Catalyst 4006 Catalyst 4503 Catalyst 4506 Modules WS-X4148-RJ45V1 WS-X4148-RJ45V Power Supplies Catalyst 4000 Family Power Entry Module (PEM) 1300 W AC 2800 W AC 1400 W DC 1. Configuring VoIP 29 C H A P T E R This chapter describes how to configure Voice-over-IP (VoIP) for IEEE 802.3af compliance • Cisco CallManager release 3.0 or later...
Software Guide
Page 555
... feature is no direct internal connection between modules installed in the chassis. • SE2 switches internal traffic and forwards traffic bound for the uplink ports to the correct SE for that switch traffic to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. To avoid such congestion, you can disable the uplink ports and...
... feature is no direct internal connection between modules installed in the chassis. • SE2 switches internal traffic and forwards traffic bound for the uplink ports to the correct SE for that switch traffic to the Catalyst 4500 Series, Catalyst 2948G, and Catalyst 2980G Switches Command Reference. To avoid such congestion, you can disable the uplink ports and...