Data Sheet
Page 5
... Mpps Supervisor 2 MSFC: up to 210 Mpps Supervisor 720: up to 400 Mpps Catalyst OS (CatOS) Cisco IOS CatOS/IOS Hybrid Configuration Yes, with stateful failover Power supplies (1+1) Switch fabric (1+1) Replaceable clock Replaceable fan tray Gateway Load Balancing Protocol Hot Standby Router Protocol Multimodule EtherChannel Rapid Spanning Tree Multiple Spanning... 1152 ports, all support Inline Power 288 ports 194 ports (2 ports provided on supervisor engine) 32 ports 12 modules with 24 port adapters 192 48 Cisco Systems, Inc. All contents are Copyright © 1992-2004...
... Mpps Supervisor 2 MSFC: up to 210 Mpps Supervisor 720: up to 400 Mpps Catalyst OS (CatOS) Cisco IOS CatOS/IOS Hybrid Configuration Yes, with stateful failover Power supplies (1+1) Switch fabric (1+1) Replaceable clock Replaceable fan tray Gateway Load Balancing Protocol Hot Standby Router Protocol Multimodule EtherChannel Rapid Spanning Tree Multiple Spanning... 1152 ports, all support Inline Power 288 ports 194 ports (2 ports provided on supervisor engine) 32 ports 12 modules with 24 port adapters 192 48 Cisco Systems, Inc. All contents are Copyright © 1992-2004...
Data Sheet
Page 18
... If a second supply is available at: http://www.cisco.com/appcontent/apollo/ configureHomeGuest.html Power All Cisco Catalyst 6500 chassis hold up to assist you in selecting the chassis, power supplies, power cables, and fan trays that will meet your requirements. All contents are available... in the following power ratings: • 950W AC input (Cisco Catalyst 6503 chassis) • 1400W AC input (Cisco Catalyst 6503 chassis) • 1000W AC input •...
... If a second supply is available at: http://www.cisco.com/appcontent/apollo/ configureHomeGuest.html Power All Cisco Catalyst 6500 chassis hold up to assist you in selecting the chassis, power supplies, power cables, and fan trays that will meet your requirements. All contents are available... in the following power ratings: • 950W AC input (Cisco Catalyst 6503 chassis) • 1400W AC input (Cisco Catalyst 6503 chassis) • 1000W AC input •...
Data Sheet
Page 19
... Numbers Catalyst 6500 Chassis Normal Speed Fan-Fan Tray Part Number 6503 FAN-MOD-3 6506 WS-C6K-6SLOT-FAN 6509 WS-C6K-6SLOT-FAN 6509-NEB WS-C6509-NEB-FAN 6509-NEB-A N/A 6513 WS-C6K-13SLOT-FAN High Speed Fan-Fan Tray Part Number FAN-MOD-3-HS(=) WS-C6K-6SLOT-FAN2 WS-C6K-9SLOT-FAN2 WS-C6509-NEB-FAN2 FAN-MOD-09(=) WS-C6K-13SLOT-FAN2 Cisco Systems, Inc. Table 4 Power Supply...
... Numbers Catalyst 6500 Chassis Normal Speed Fan-Fan Tray Part Number 6503 FAN-MOD-3 6506 WS-C6K-6SLOT-FAN 6509 WS-C6K-6SLOT-FAN 6509-NEB WS-C6509-NEB-FAN 6509-NEB-A N/A 6513 WS-C6K-13SLOT-FAN High Speed Fan-Fan Tray Part Number FAN-MOD-3-HS(=) WS-C6K-6SLOT-FAN2 WS-C6K-9SLOT-FAN2 WS-C6509-NEB-FAN2 FAN-MOD-09(=) WS-C6K-13SLOT-FAN2 Cisco Systems, Inc. Table 4 Power Supply...
User Guide
Page 4
... to reduce costs. With numerous network modules and service modules available, the modular architecture of the Cisco router easily allows interfaces to be upgraded to branch offices. Figure 1 Catalyst 6509 Switch Supervisor engine Redundant supervisor engine Switching modules Fan assembly 1 2 3 4 5 6 7 8 FAN STATUS 9 WS-X6K-SUP2-2GE STATUS SYSTEMCONSOLPEWR MGRMETSET SUPERVISOR2 CONSOLE CONSOLE PORT MODE...
... to reduce costs. With numerous network modules and service modules available, the modular architecture of the Cisco router easily allows interfaces to be upgraded to branch offices. Figure 1 Catalyst 6509 Switch Supervisor engine Redundant supervisor engine Switching modules Fan assembly 1 2 3 4 5 6 7 8 FAN STATUS 9 WS-X6K-SUP2-2GE STATUS SYSTEMCONSOLPEWR MGRMETSET SUPERVISOR2 CONSOLE CONSOLE PORT MODE...
User Guide
Page 5
Catalyst 6509 Switch and Cisco 7606 and Cisco 7609 Routers Figure 2 Cisco 7606 Router PEM 1 PEM 2 Supervisor Engine OSMs WS-X6K-SUP2-2GE STATUS SYSTEMCONSOLPEWR MGRMETSET SUPERVISOR2 CONSOLE CONSOLE PORT MODE PCMCIA EJECT OSM-4OC12 POS-SI 1 STATUS 2 4 PORT OC-12 POS SM IR ...TX PORT 3 ACTIVE TX RX CARRAILEARRM RX TX PORT4 ACTIVE TX RX CARRAILEARRM RX TX PORT 3 ACTIVE TX RX CARRAILEARRM RX TX PORT4 Fan assembly Slots 1-6 (top to bottom) 63892 OL-6334-01 Catalyst 6509 Switch, Cisco 7606 Router, and Cisco 7609 Router with VPN Services Module Certification Note 5
Catalyst 6509 Switch and Cisco 7606 and Cisco 7609 Routers Figure 2 Cisco 7606 Router PEM 1 PEM 2 Supervisor Engine OSMs WS-X6K-SUP2-2GE STATUS SYSTEMCONSOLPEWR MGRMETSET SUPERVISOR2 CONSOLE CONSOLE PORT MODE PCMCIA EJECT OSM-4OC12 POS-SI 1 STATUS 2 4 PORT OC-12 POS SM IR ...TX PORT 3 ACTIVE TX RX CARRAILEARRM RX TX PORT4 ACTIVE TX RX CARRAILEARRM RX TX PORT 3 ACTIVE TX RX CARRAILEARRM RX TX PORT4 Fan assembly Slots 1-6 (top to bottom) 63892 OL-6334-01 Catalyst 6509 Switch, Cisco 7606 Router, and Cisco 7609 Router with VPN Services Module Certification Note 5
User Guide
Page 6
... Figure 3 Cisco 7609 Router WS-X6K-SUP2-2GE STATUSSYSTEMCONSOLPEWR MGRMETSET CONSOLE SUPERVISOR2 WS-X6K-SUP2-2GE STATUSSYSTEMCONSOLPEWR MGRMETSET CONSOLE SUPERVISOR2 OSM-40C12-POS-MM OC12 POS MM OSM-40C12-POS-MM STATUS OC12 POS MM WS-C6500-SFM STATUS 2 1 1 2 LINK 1 LINK 1 LINK 2 LINK 2 3 3 CONSOLE PORT MODE CONSOLE PORT MODE 4 LINK 3 4 LINK 3 OSMs FAN STATUS Fan assembly...
... Figure 3 Cisco 7609 Router WS-X6K-SUP2-2GE STATUSSYSTEMCONSOLPEWR MGRMETSET CONSOLE SUPERVISOR2 WS-X6K-SUP2-2GE STATUSSYSTEMCONSOLPEWR MGRMETSET CONSOLE SUPERVISOR2 OSM-40C12-POS-MM OC12 POS MM OSM-40C12-POS-MM STATUS OC12 POS MM WS-C6500-SFM STATUS 2 1 1 2 LINK 1 LINK 1 LINK 2 LINK 2 3 3 CONSOLE PORT MODE CONSOLE PORT MODE 4 LINK 3 4 LINK 3 OSMs FAN STATUS Fan assembly...
User Guide
Page 8
...is operational and active. Orange The link has been disabled by software. Orange The power supply has failed or the power supply fan has failed. Incompatible power supplies are reporting OK. One VTT2 module has failed or the VTT module temperature minor threshold has ... card is not operational because a fault occurred during environmental monitoring.) All chassis environmental monitors are installed. Catalyst 6509 Switch, Cisco 7606 Router, and Cisco 7609 Router with VPN Services Module Certification Note 8 OL-6334-01 Orange The module is detected. Orange Off No signal ...
...is operational and active. Orange The link has been disabled by software. Orange The power supply has failed or the power supply fan has failed. Incompatible power supplies are reporting OK. One VTT2 module has failed or the VTT module temperature minor threshold has ... card is not operational because a fault occurred during environmental monitoring.) All chassis environmental monitors are installed. Catalyst 6509 Switch, Cisco 7606 Router, and Cisco 7609 Router with VPN Services Module Certification Note 8 OL-6334-01 Orange The module is detected. Orange Off No signal ...
User Guide
Page 14
...the Catalyst 6509 Switch Opacity shield material removed for clarity Shield screw WS-X6K-SUP2-2GE 1 STATUS SYSTEMCONSOLPEWR MGRMETSET CONSOLE PORT CONSOLE MODE SUPERVISOR2 2 3 WS-SVC-IPSEC-1 4 STATUS IPSec VPN Acceleration Services Module 5 6 7 8 FAN STATUS 9 PCMCIA EJECT Switch Load 100% 1% PORT 1 LINK ...PORT 2 LINK o o INPUT OK FAN OUTPUT OK FAIL INPUT OK FAN OUTPUT OK FAIL Chassis shown removed from rack for clarity M-4 snap rivet pin M-4 snap rivet sleeve Catalyst 6509 Switch, Cisco 7606 Router, and Cisco 7609 Router with VPN Services Module Certification ...
...the Catalyst 6509 Switch Opacity shield material removed for clarity Shield screw WS-X6K-SUP2-2GE 1 STATUS SYSTEMCONSOLPEWR MGRMETSET CONSOLE PORT CONSOLE MODE SUPERVISOR2 2 3 WS-SVC-IPSEC-1 4 STATUS IPSec VPN Acceleration Services Module 5 6 7 8 FAN STATUS 9 PCMCIA EJECT Switch Load 100% 1% PORT 1 LINK ...PORT 2 LINK o o INPUT OK FAN OUTPUT OK FAIL INPUT OK FAN OUTPUT OK FAIL Chassis shown removed from rack for clarity M-4 snap rivet pin M-4 snap rivet sleeve Catalyst 6509 Switch, Cisco 7606 Router, and Cisco 7609 Router with VPN Services Module Certification ...
User Guide
Page 18
...labels should be removed to allow access to the chassis. Note Use the same procedure to apply tamper evidence labels to remove the fan tray will damage the tamper seal, which indicates tampering has occurred. The chassis temperature should be accessed without indicating signs of the ...and the other half adheres to the network modules and the service modules. d. Place labels on the Cisco 7606 router. Any attempt to operate in order to remove the fan tray will damage the tamper seal, which indicates tampering has occurred. Any chassis slot that one half of...
...labels should be removed to allow access to the chassis. Note Use the same procedure to apply tamper evidence labels to remove the fan tray will damage the tamper seal, which indicates tampering has occurred. The chassis temperature should be accessed without indicating signs of the ...and the other half adheres to the network modules and the service modules. d. Place labels on the Cisco 7606 router. Any attempt to operate in order to remove the fan tray will damage the tamper seal, which indicates tampering has occurred. Any chassis slot that one half of...
User Guide
Page 19
... installed in either Figure 7 (Catalyst 6509 switch), Figure 8 (Cisco 7606 router), or Figure 9 (Cisco 7609 router). Figure 7 Catalyst 6509 Switch Chassis Tamper Evidence Label Placement WS-X6K-SUP2-2GE 1 STATUS SYSTEMCONSOLPEWR MGRMETSET CONSOLE PORT CONSOLE MODE SUPERVISOR2 2 3 WS-SVC-IPSEC-1 4 STATUS IPSec VPN Acceleration Services Module 5 6 7 8 FAN STATUS 9 PCMCIA EJECT Switch Load 100% 1% PORT 1 LINK...
... installed in either Figure 7 (Catalyst 6509 switch), Figure 8 (Cisco 7606 router), or Figure 9 (Cisco 7609 router). Figure 7 Catalyst 6509 Switch Chassis Tamper Evidence Label Placement WS-X6K-SUP2-2GE 1 STATUS SYSTEMCONSOLPEWR MGRMETSET CONSOLE PORT CONSOLE MODE SUPERVISOR2 2 3 WS-SVC-IPSEC-1 4 STATUS IPSec VPN Acceleration Services Module 5 6 7 8 FAN STATUS 9 PCMCIA EJECT Switch Load 100% 1% PORT 1 LINK...
Upgrade Guide
Page 1
...-7609 Router to use the Supervisor Engine 720 and the Supervisor Engine 32. Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note Product Number: WS-6509-NEB-UPGRD= This publication describes how to upgrade your switch or router is using a DC-input power supply, you are required to ...install the WS-CAC-3000W power supply. Caution It is rated 10 A @ -40 to power the fan tray. Each input of the fan tray is important that you are required to power the fan tray. The 3000 W AC-input provides a power output to install...
...-7609 Router to use the Supervisor Engine 720 and the Supervisor Engine 32. Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note Product Number: WS-6509-NEB-UPGRD= This publication describes how to upgrade your switch or router is using a DC-input power supply, you are required to ...install the WS-CAC-3000W power supply. Caution It is rated 10 A @ -40 to power the fan tray. Each input of the fan tray is important that you are required to power the fan tray. The 3000 W AC-input provides a power output to install...
Upgrade Guide
Page 2
...• Installation Guidelines, page 4 • Shutting Down the System, page 4 • Replacing the Panel Safety Cover, page 5 • Replacing the Fan Tray, page 7 • Replacing the Power Supply, page 10 • Connecting Power to locate its translation in a situation that power is removed from the...involved with standard practices for preventing accidents. Statement 1028 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 2 78-16162-02 A warning symbol precedes each warning to the Fan Tray, page 13 • Replacing the Supervisor Engine, page 17 • ...
...• Installation Guidelines, page 4 • Shutting Down the System, page 4 • Replacing the Panel Safety Cover, page 5 • Replacing the Fan Tray, page 7 • Replacing the Power Supply, page 10 • Connecting Power to locate its translation in a situation that power is removed from the...involved with standard practices for preventing accidents. Statement 1028 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 2 78-16162-02 A warning symbol precedes each warning to the Fan Tray, page 13 • Replacing the Supervisor Engine, page 17 • ...
Upgrade Guide
Page 3
.... Statement 1045 Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. The high speed fan tray requires external power, either from the 3000 W AC-input power supply or from an external DC power source. Statement 1046 Parts List...head screwdriver • Number 2 Phillips-head screwdriver • Flat-blade screwdriver (for DC-input systems) 78-16162-02 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 3 Statement 1030 Warning Hazardous voltage or energy is present on the backplane when the system is operating.
.... Statement 1045 Warning When installing or replacing the unit, the ground connection must always be made first and disconnected last. The high speed fan tray requires external power, either from the 3000 W AC-input power supply or from an external DC power source. Statement 1046 Parts List...head screwdriver • Number 2 Phillips-head screwdriver • Flat-blade screwdriver (for DC-input systems) 78-16162-02 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 3 Statement 1030 Warning Hazardous voltage or energy is present on the backplane when the system is operating.
Upgrade Guide
Page 4
... to a separate input source. Before you shut down the system, you are required to install the WS-CAC-3000W power supply. This saves time when bringing the module back online. Each input of the fan tray is rated 10 A @ -40 to -60 VDC. • Observe the following cautions: ...and remove power supplies. For more information, refer to the "Working with internal components. On any modules running Cisco IOS, save the running configuration. Statement 1 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 4 78-16162-02 You must shut down the system, follow the steps in...
... to a separate input source. Before you shut down the system, you are required to install the WS-CAC-3000W power supply. This saves time when bringing the module back online. Each input of the fan tray is rated 10 A @ -40 to -60 VDC. • Observe the following cautions: ...and remove power supplies. For more information, refer to the "Working with internal components. On any modules running Cisco IOS, save the running configuration. Statement 1 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 4 78-16162-02 You must shut down the system, follow the steps in...
Upgrade Guide
Page 6
... press the panel into place, starting at the bottom of the chassis. (See Figure 2.) Proceed to the "Replacing the Fan Tray" section on page 7 to replace the fan tray. Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 6 78-16162-02 Be careful not to install the 8 panel screws, 4 each located...
... press the panel into place, starting at the bottom of the chassis. (See Figure 2.) Proceed to the "Replacing the Fan Tray" section on page 7 to replace the fan tray. Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 6 78-16162-02 Be careful not to install the 8 panel screws, 4 each located...
Upgrade Guide
Page 7
A flat-blade or number 2 Phillips-head screwdriver is required to remove and install the fan tray for the Catalyst 6509-NEB switch and Cisco OSR-7609 Router. The standard fan tray (WS-C6509-NEB-FAN) must be removed and replaced with the high-speed fan tray (WS-C6509-NEB-FAN2). Figure 2 Installing the Panel Safety Cover Replacing the Fan Tray 105071 Replacing the Fan Tray This section describes how to perform this procedure. 78-16162-02 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 7
A flat-blade or number 2 Phillips-head screwdriver is required to remove and install the fan tray for the Catalyst 6509-NEB switch and Cisco OSR-7609 Router. The standard fan tray (WS-C6509-NEB-FAN) must be removed and replaced with the high-speed fan tray (WS-C6509-NEB-FAN2). Figure 2 Installing the Panel Safety Cover Replacing the Fan Tray 105071 Replacing the Fan Tray This section describes how to perform this procedure. 78-16162-02 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 7
Upgrade Guide
Page 8
... standard fan tray (WS-C6509-NEB-FAN), follow these steps: Step 1 Use a flat-blade or number 2 Phillips-head screwdriver to unseat the power connector from the spinning fan blades. Replacing the Fan Tray Removing the Fan Tray Warning When removing the fan tray, keep your hands and fingers away from the backplane. Catalyst 6509-NEB Switch and Cisco OSR...
... standard fan tray (WS-C6509-NEB-FAN), follow these steps: Step 1 Use a flat-blade or number 2 Phillips-head screwdriver to unseat the power connector from the spinning fan blades. Replacing the Fan Tray Removing the Fan Tray Warning When removing the fan tray, keep your hands and fingers away from the backplane. Catalyst 6509-NEB Switch and Cisco OSR...
Upgrade Guide
Page 9
... Cisco OSR-7609 Router Upgrade Note 9 Proceed to the "Replacing the Power Supply" section on the chassis, and then lift the fan tray up slightly, aligning the top and bottom chassis guides. Replacing the Fan Tray Installing the High Speed Fan Tray To install the high speed fan tray (WS-C6509-NEB...-FAN2), follow these steps: Step 1 Hold the fan tray with the chassis. Push the fan tray into the chassis until the power connector seats in...
... Cisco OSR-7609 Router Upgrade Note 9 Proceed to the "Replacing the Power Supply" section on the chassis, and then lift the fan tray up slightly, aligning the top and bottom chassis guides. Replacing the Fan Tray Installing the High Speed Fan Tray To install the high speed fan tray (WS-C6509-NEB...-FAN2), follow these steps: Step 1 Hold the fan tray with the chassis. Push the fan tray into the chassis until the power connector seats in...
Upgrade Guide
Page 10
Replacing the Power Supply Replacing the Power Supply Note DC-input systems-See the "Connecting Site Power to the Fan Tray for the Catalyst 6509-NEB switch and Cisco OSR-7609 router. Step 2 Grasp the power supply handle with one hand, and slide the power supply part of the way...5 AC-Input Power Supply Front Panel AC power connection Cable retention device Power switch I 0 INPUT OK FAN OUTPUT OK FAIL Status LEDs Captive installation screw 16029 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 10 78-16162-02 Removing an AC-Input Power Supply Warning Hazardous voltage...
Replacing the Power Supply Replacing the Power Supply Note DC-input systems-See the "Connecting Site Power to the Fan Tray for the Catalyst 6509-NEB switch and Cisco OSR-7609 router. Step 2 Grasp the power supply handle with one hand, and slide the power supply part of the way...5 AC-Input Power Supply Front Panel AC power connection Cable retention device Power switch I 0 INPUT OK FAN OUTPUT OK FAIL Status LEDs Captive installation screw 16029 Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 10 78-16162-02 Removing an AC-Input Power Supply Warning Hazardous voltage...
Upgrade Guide
Page 11
Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 11 Replacing the Power Supply 105074 48V INPUT 2 FAN FAIL INPOUT POWER GOOD RTN -48VDC GND HIGH SPEED FAN SELECT STATUS ACTIVE Figure 6 Removing an AC-Input Power Supply WS-X6K-SUP2-2GE STATUSSYSTEMCONSOLPEWR MGRMETSET CONSOLE... CAARLRAIREMR RX PORT 1 CAARLRAIREMR RX PORT 2 CAARLRAIREMR RX PORT 3 CAARLRAIREMR RX LINK 4 NEXT SWITCH FABRIC MDL WS-C6500-SFM SELECT STATUS ACTIVE NEXT OK FAIL INPUT FAN OUTPUT WS-C6500-NEB-FAN2 GOOD GND INPOUT POWER SWITCH FABRIC MDL OSM-40C12-POS-MM STATUS OC12 POS MM 1 2...
Catalyst 6509-NEB Switch and Cisco OSR-7609 Router Upgrade Note 11 Replacing the Power Supply 105074 48V INPUT 2 FAN FAIL INPOUT POWER GOOD RTN -48VDC GND HIGH SPEED FAN SELECT STATUS ACTIVE Figure 6 Removing an AC-Input Power Supply WS-X6K-SUP2-2GE STATUSSYSTEMCONSOLPEWR MGRMETSET CONSOLE... CAARLRAIREMR RX PORT 1 CAARLRAIREMR RX PORT 2 CAARLRAIREMR RX PORT 3 CAARLRAIREMR RX LINK 4 NEXT SWITCH FABRIC MDL WS-C6500-SFM SELECT STATUS ACTIVE NEXT OK FAIL INPUT FAN OUTPUT WS-C6500-NEB-FAN2 GOOD GND INPOUT POWER SWITCH FABRIC MDL OSM-40C12-POS-MM STATUS OC12 POS MM 1 2...