HP Uninterruptible Power System R6000 Models User Guide
Page 4
... Chapter 4 Battery Maintenance Precautions ...4-1 Charging Batteries...4-1 Determining When to Replace Batteries 4-2 Obtaining New Batteries ...4-2 Replacing the Batteries...4-2 Removing the Battery Pack ...4-3 Installing a New Battery Pack ...4-6 Testing the New Battery Pack ...4-6 Disposing of Used Batteries ...4-7 Care and Storage of Batteries...4-7 Pre-Failure Battery Warranty...4-8 Chapter 5 Troubleshooting Responding to Audible Alarms ...5-1 Trouble Indicators ...5-4 LED Alarm Configurations ...5-4 Repairing the UPS...5-5 iv HP Uninterruptible Power System R6000 Models...
... Chapter 4 Battery Maintenance Precautions ...4-1 Charging Batteries...4-1 Determining When to Replace Batteries 4-2 Obtaining New Batteries ...4-2 Replacing the Batteries...4-2 Removing the Battery Pack ...4-3 Installing a New Battery Pack ...4-6 Testing the New Battery Pack ...4-6 Disposing of Used Batteries ...4-7 Care and Storage of Batteries...4-7 Pre-Failure Battery Warranty...4-8 Chapter 5 Troubleshooting Responding to Audible Alarms ...5-1 Trouble Indicators ...5-4 LED Alarm Configurations ...5-4 Repairing the UPS...5-5 iv HP Uninterruptible Power System R6000 Models...
HP Uninterruptible Power System R6000 Models User Guide
Page 5
... Marked with the FCC Logo, United States Only A-2 Modifications ...A-2 Cables...A-3 Canadian Notice (Avis Canadien) ...A-3 Class A Equipment...A-3 Class B Equipment ...A-3 European Union Notice ...A-3 Japanese Notice ...A-4 BSMI Notice...A-4 Battery Replacement Notice ...A-5 Appendix B Electrostatic Discharge Preventing Electrostatic Damage...B-1 Grounding Methods To Prevent Electrostatic Damage B-1 Appendix C Specifications Physical Specifications ...C-1 Input Specifications ...C-1 Output Specifications...
... Marked with the FCC Logo, United States Only A-2 Modifications ...A-2 Cables...A-3 Canadian Notice (Avis Canadien) ...A-3 Class A Equipment...A-3 Class B Equipment ...A-3 European Union Notice ...A-3 Japanese Notice ...A-4 BSMI Notice...A-4 Battery Replacement Notice ...A-5 Appendix B Electrostatic Discharge Preventing Electrostatic Damage...B-1 Grounding Methods To Prevent Electrostatic Damage B-1 Appendix C Specifications Physical Specifications ...C-1 Input Specifications ...C-1 Output Specifications...
HP Uninterruptible Power System R6000 Models User Guide
Page 34
If this alarm is triggered while the UPS is on the utility voltage, the battery test has failed and the batteries must be replaced. Check the utility voltage connection. continued HP Uninterruptible Power System R6000 Models User Guide 3-7 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM...
If this alarm is triggered while the UPS is on the utility voltage, the battery test has failed and the batteries must be replaced. Check the utility voltage connection. continued HP Uninterruptible Power System R6000 Models User Guide 3-7 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM...
HP Uninterruptible Power System R6000 Models User Guide
Page 35
... Main Menu to display the amount of charge on the battery. Control Board Version x. x x 3-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM This is imminent. Battery replacement is disabled for the UPS components. x x This menu selection shows...
... Main Menu to display the amount of charge on the battery. Control Board Version x. x x 3-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/13/02 12:54 PM This is imminent. Battery replacement is disabled for the UPS components. x x This menu selection shows...
HP Uninterruptible Power System R6000 Models User Guide
Page 41
... contains information for properly maintaining batteries for information on keeping the batteries charged while the UPS is in extended storage. WARNING: To reduce the risk of Batteries," in this chapter for the UPS, including battery charging, replacement, disposal procedures, and warranties....Charging Batteries When connected to temperatures higher than 60°C (140°F). Precautions WARNING: There is in water. • Do not expose to utility power, the UPS automatically charges the batteries. WARNING: The UPS contains an internal lithium battery and a sealed lead-acid battery ...
... contains information for properly maintaining batteries for information on keeping the batteries charged while the UPS is in extended storage. WARNING: To reduce the risk of Batteries," in this chapter for the UPS, including battery charging, replacement, disposal procedures, and warranties....Charging Batteries When connected to temperatures higher than 60°C (140°F). Precautions WARNING: There is in water. • Do not expose to utility power, the UPS automatically charges the batteries. WARNING: The UPS contains an internal lithium battery and a sealed lead-acid battery ...
HP Uninterruptible Power System R6000 Models User Guide
Page 42
... Vdc across the batteries. 4-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 2/20/03 2:59 PM It is recommended that battery replacement is required by initiating a UPS self-test. Only replace batteries with an internal lithium battery and a sealed lead-acid battery module. For more information about battery replacement or proper...
... Vdc across the batteries. 4-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 2/20/03 2:59 PM It is recommended that battery replacement is required by initiating a UPS self-test. Only replace batteries with an internal lithium battery and a sealed lead-acid battery module. For more information about battery replacement or proper...
HP Uninterruptible Power System R6000 Models User Guide
Page 43
Figure 4-2: Removing screws from the lower front bezel HP Uninterruptible Power System R6000 Models User Guide 4-3 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM Place the UPS in Manual Bypass mode 2. Using a Philips screwdriver, remove the lower front bezel by backing off the captive screws on each side. Figure 4-1: Placing the UPS in Bypass mode using the manual switch located at the rear of the UPS. Battery Maintenance Removing the Battery Pack To replace the batteries:. 1.
Figure 4-2: Removing screws from the lower front bezel HP Uninterruptible Power System R6000 Models User Guide 4-3 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM Place the UPS in Manual Bypass mode 2. Using a Philips screwdriver, remove the lower front bezel by backing off the captive screws on each side. Figure 4-1: Placing the UPS in Bypass mode using the manual switch located at the rear of the UPS. Battery Maintenance Removing the Battery Pack To replace the batteries:. 1.
HP Uninterruptible Power System R6000 Models User Guide
Page 44
... position before continuing with the battery replacement. Squeeze the release tabs on the sides of the battery cable connectors to disconnect the cables from the battery. WARNING: Once the bezel is removed, the battery circuit breakers MUST be in the off position. Battery Maintenance 3. Figure 4-4: Disconnecting the battery cables 4-4 HP Uninterruptible Power System R6000 Models User Guide HP...
... position before continuing with the battery replacement. Squeeze the release tabs on the sides of the battery cable connectors to disconnect the cables from the battery. WARNING: Once the bezel is removed, the battery circuit breakers MUST be in the off position. Battery Maintenance 3. Figure 4-4: Disconnecting the battery cables 4-4 HP Uninterruptible Power System R6000 Models User Guide HP...
HP Uninterruptible Power System R6000 Models User Guide
Page 45
... UPS chassis, remove the battery connector covers and place them on the batteries that were removed from the unit. 7. Battery Maintenance 5. HP Uninterruptible Power System R6000 Models User Guide 4-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM As soon as the replacement batteries are safely in place in...
... UPS chassis, remove the battery connector covers and place them on the batteries that were removed from the unit. 7. Battery Maintenance 5. HP Uninterruptible Power System R6000 Models User Guide 4-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 2:44 PM As soon as the replacement batteries are safely in place in...
HP Uninterruptible Power System R6000 Models User Guide
Page 46
...the LCD menu indicates an alarm. Remove the connector covers from the new batteries and replace the screw used battery housing. 4. Refer to 90 percent of the connector. NOTE: When reattaching the battery connector cables, do not hold the connectors by a solid green LED. Reattach...using the captive screws at least 90 percent charged. After installing the new batteries, press the Test/Alarm Reset button to Chapter 5, "Troubleshooting," for 24 hours. 4-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last ...
...the LCD menu indicates an alarm. Remove the connector covers from the new batteries and replace the screw used battery housing. 4. Refer to 90 percent of the connector. NOTE: When reattaching the battery connector cables, do not hold the connectors by a solid green LED. Reattach...using the captive screws at least 90 percent charged. After installing the new batteries, press the Test/Alarm Reset button to Chapter 5, "Troubleshooting," for 24 hours. 4-6 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last ...
HP Uninterruptible Power System R6000 Models User Guide
Page 48
... notification from power management software that the battery may fail, the battery is replaced free of the following ways: • An LED showing that the battery is low • Notification from power management software This warning provides ample time to a battery failure. The warning is replaced. 4-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename...
... notification from power management software that the battery may fail, the battery is replaced free of the following ways: • An LED showing that the battery is low • Notification from power management software This warning provides ample time to a battery failure. The warning is replaced. 4-8 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename...
HP Uninterruptible Power System R6000 Models User Guide
Page 53
...HP or an HP authorized service representative. Check the manual Bypass switch on . Wait for the shutdown to complete. HP Uninterruptible Power System R6000 Models User Guide 5-5 All LEDs are no load present. The LED is solid green and the LED is not successful, contact an authorized...voltage and/or frequency is flashing red. There is solid yellow. The LED is a hot start on battery power. An alarm condition exists. Allow the self-test to complete. Other than battery replacement, there are on the UPS rear panel. Allow the self-test to complete. The load is solid...
...HP or an HP authorized service representative. Check the manual Bypass switch on . Wait for the shutdown to complete. HP Uninterruptible Power System R6000 Models User Guide 5-5 All LEDs are no load present. The LED is solid green and the LED is not successful, contact an authorized...voltage and/or frequency is flashing red. There is solid yellow. The LED is a hot start on battery power. An alarm condition exists. Allow the self-test to complete. Other than battery replacement, there are on the UPS rear panel. Allow the self-test to complete. The load is solid...
HP Uninterruptible Power System R6000 Models User Guide
Page 58
... risk of together with an internal lithium battery or battery pack. HP Uninterruptible Power System R6000 Models User Guide A-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 7:59 AM WARNING: The UPS contains an internal lithium battery or battery pack. Regulatory Compliance Notices Battery Replacement Notice The UPS is equipped with...
... risk of together with an internal lithium battery or battery pack. HP Uninterruptible Power System R6000 Models User Guide A-5 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 7:59 AM WARNING: The UPS contains an internal lithium battery or battery pack. Regulatory Compliance Notices Battery Replacement Notice The UPS is equipped with...
HP Uninterruptible Power System R6000 Models User Guide
Page 64
... 3-7 altitude, operating C-4 audible alarms 2-6 enabling and disabling 3-11 responding to 5-1 silencing 2-7 audible noise C-4 B backup times C-4 batteries caring for and storing 4-7 charging 2-5, 4-1 determining when to replace 4-2 disposing of 4-7 installing 4-6 obtaining new 4-2 precautions 4-1 Pre-Failure Warranty 4-8 recycling or disposal A-5 removing 4-3, 4-5 runtime C-4 ...3-2, 3-13 controls, front panel 2-1 counting active alarms 3-5 HP Uninterruptible Power System R6000 Models User Guide Index-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 8:26 AM
... 3-7 altitude, operating C-4 audible alarms 2-6 enabling and disabling 3-11 responding to 5-1 silencing 2-7 audible noise C-4 B backup times C-4 batteries caring for and storing 4-7 charging 2-5, 4-1 determining when to replace 4-2 disposing of 4-7 installing 4-6 obtaining new 4-2 precautions 4-1 Pre-Failure Warranty 4-8 recycling or disposal A-5 removing 4-3, 4-5 runtime C-4 ...3-2, 3-13 controls, front panel 2-1 counting active alarms 3-5 HP Uninterruptible Power System R6000 Models User Guide Index-1 HP CONFIDENTIAL Codename: Arcuda Part Number: 347223-003 Last Saved On: 12/12/02 8:26 AM
HP Uninterruptible Power System R6000 Models User Guide
Page 65
...depth C-1 determining when to replace batteries 4-2 diagnostics 2-6 dimensions C-1 disconnecting battery cables 4-4 Display Test menu 3-9 display, LCD 2-2 displaying active alarms 3-7 battery data 3-8 firmware versions 3-8 receptacle status 3-5 voltage, frequency, and power 3-6 disposing of used batteries 4-7 E electric shock ...testing 3-9 LCD menus Active Alarms 3-7 Battery Data 3-8 Display Test 3-9 Firmware Version 3-8 Load Control 3-9 Main 3-3 map 3-4 Meters 3-6 Status 3-5 System Setup 3-10 Index-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda...
...depth C-1 determining when to replace batteries 4-2 diagnostics 2-6 dimensions C-1 disconnecting battery cables 4-4 Display Test menu 3-9 display, LCD 2-2 displaying active alarms 3-7 battery data 3-8 firmware versions 3-8 receptacle status 3-5 voltage, frequency, and power 3-6 disposing of used batteries 4-7 E electric shock ...testing 3-9 LCD menus Active Alarms 3-7 Battery Data 3-8 Display Test 3-9 Firmware Version 3-8 Load Control 3-9 Main 3-3 map 3-4 Meters 3-6 Status 3-5 System Setup 3-10 Index-2 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: Arcuda...
HP Uninterruptible Power System R6000 Models User Guide
Page 67
...C-4 Remote Emergency Power Off Port See REPO port removing batteries 4-5 front bezel 4-3 repairing the UPS 5-5 replacing batteries 4-3 REPO port 1-11 RS-232 port See DE9 communication port runtime battery C-4 increasing 1-10 S safety information vii Scalable UPS ...Alarm Reset button 2-1, 2-6, 2-7 testing batteries 4-6 LCD display 3-9 UPS 2-6 text conventions viii U UPS battery maintenance 4-1 configuring 3-1 installing 2-1 models 1-2 operation 2-1 overview 1-1 repairing 5-5 specifications C-1 troubleshooting 5-1 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: ...
...C-4 Remote Emergency Power Off Port See REPO port removing batteries 4-5 front bezel 4-3 repairing the UPS 5-5 replacing batteries 4-3 REPO port 1-11 RS-232 port See DE9 communication port runtime battery C-4 increasing 1-10 S safety information vii Scalable UPS ...Alarm Reset button 2-1, 2-6, 2-7 testing batteries 4-6 LCD display 3-9 UPS 2-6 text conventions viii U UPS battery maintenance 4-1 configuring 3-1 installing 2-1 models 1-2 operation 2-1 overview 1-1 repairing 5-5 specifications C-1 troubleshooting 5-1 HP Uninterruptible Power System R6000 Models User Guide HP CONFIDENTIAL Codename: ...
HP UPS Battery Best Practices
Page 1
...forward them to recycling or proper disposal, use the public collection system or return them to the battery manufacturer's specifications. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. © Copyright 2009...herein should not be liable for proper UPS operation. Battery performance also slightly degrades later in the express warranty statements accompanying such products and services. HP UPS Battery Best Practices Battery replacement HP UPSs incorporate Extended Runtime Modules (ERMs), which ...
...forward them to recycling or proper disposal, use the public collection system or return them to the battery manufacturer's specifications. For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider. © Copyright 2009...herein should not be liable for proper UPS operation. Battery performance also slightly degrades later in the express warranty statements accompanying such products and services. HP UPS Battery Best Practices Battery replacement HP UPSs incorporate Extended Runtime Modules (ERMs), which ...
HP UPS Best Practices
Page 1
HP UPS Best Practices Abstract...2 Introduction ...2 The Importance of Power Protection 2 Recommended Duration of 27 Page 1 of Use...2 Battery Replacement ...3 Select Load Appropriately / Sizing A UPS 3 Select Application Voltage / High volt VS Low Volt (120V or 208V 3 HP UPS Management...4 HP Power Manager Software...4 HP Management ...
HP UPS Best Practices Abstract...2 Introduction ...2 The Importance of Power Protection 2 Recommended Duration of 27 Page 1 of Use...2 Battery Replacement ...3 Select Load Appropriately / Sizing A UPS 3 Select Application Voltage / High volt VS Low Volt (120V or 208V 3 HP UPS Management...4 HP Power Manager Software...4 HP Management ...
HP UPS Best Practices
Page 7
..., without consuming valuable rack space. and R5500 occupies only 3U (5.25 inches), leaving more space for server and storage equipment Industry-leading Power Density The R1500 G2 packs 1340 Watts into just 1U, while the R3000 delivers an unprecedented 2700 watts in rack... maximize power distribution and space efficiencies in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 7 of -failure...
..., without consuming valuable rack space. and R5500 occupies only 3U (5.25 inches), leaving more space for server and storage equipment Industry-leading Power Density The R1500 G2 packs 1340 Watts into just 1U, while the R3000 delivers an unprecedented 2700 watts in rack... maximize power distribution and space efficiencies in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 7 of -failure...
HP UPS Best Practices
Page 12
...; Prioritized shutdown to alarm conditions Best-in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 12 of 27 HP... is saved during an extended blackout Serial and USB ports for data exchange with the host computer Hot-swappable batteries for simplified service without powering down the UPS Power Management Software o Bundled free with an enhanced front panel display.
...; Prioritized shutdown to alarm conditions Best-in the industry, reducing total cost of ownership and system downtime HP pre-failure warranty replaces batteries free of charge within 3-year period $250,000 computer load protection guarantee provides additional peace of mind Page 12 of 27 HP... is saved during an extended blackout Serial and USB ports for data exchange with the host computer Hot-swappable batteries for simplified service without powering down the UPS Power Management Software o Bundled free with an enhanced front panel display.