Testing on HP Business Desktop PCs
Page 3
...tools provide detailed error messages that each component used during product development. Hard Drive and Removable Storage interfaces - Parallel, Serial, and USB 1.0/2.0 ports, Bluetooth, and Firewire - A dedicated tool development team was to design software image databases, processes, and tools ...• Test Management-Database tools enable test teams to generate and manage test plans and test procedures in 1998. PCI/PCI-X/AGP/PCI Express Graphics subsystems - Hardware Evaluation Test Development The Evaluation Test Development (ETD) team designs and provides hardware and ...
...tools provide detailed error messages that each component used during product development. Hard Drive and Removable Storage interfaces - Parallel, Serial, and USB 1.0/2.0 ports, Bluetooth, and Firewire - A dedicated tool development team was to design software image databases, processes, and tools ...• Test Management-Database tools enable test teams to generate and manage test plans and test procedures in 1998. PCI/PCI-X/AGP/PCI Express Graphics subsystems - Hardware Evaluation Test Development The Evaluation Test Development (ETD) team designs and provides hardware and ...
Quick Setup and Getting Started Guide
Page 14
... computer. System-Shows information about the computer. In the View level field, you a listing of information about the computer parallel (LPT) and serial (COM) port settings, plus internal speaker and PCI bus information. 6 Quick Setup & Getting Started ENWW Overview-Gives you can select the following categories of information to see limited configuration data...
... computer. System-Shows information about the computer. In the View level field, you a listing of information about the computer parallel (LPT) and serial (COM) port settings, plus internal speaker and PCI bus information. 6 Quick Setup & Getting Started ENWW Overview-Gives you can select the following categories of information to see limited configuration data...
Desktop Management Guide
Page 31
... enable/disable the Smart Card to be embedded on the PCI bus or be used to Factory Settings. See the HP ProtectTools Security Manager Guide at http://www.hp.com Device Security Enables/disables serial ports, parallel port, front USB ports, system audio, network controllers (some models), and SCSI controllers...ID entry. NOTE: Notify User alerts the user that the sensor has detected that the setup password be updated if the current chassis serial number is supported on some models). ENWW 25 This feature is invalid. (These ID numbers are used in place of the PowerOn Password...
... enable/disable the Smart Card to be embedded on the PCI bus or be used to Factory Settings. See the HP ProtectTools Security Manager Guide at http://www.hp.com Device Security Enables/disables serial ports, parallel port, front USB ports, system audio, network controllers (some models), and SCSI controllers...ID entry. NOTE: Notify User alerts the user that the sensor has detected that the setup password be updated if the current chassis serial number is supported on some models). ENWW 25 This feature is invalid. (These ID numbers are used in place of the PowerOn Password...
Installing Windows® 7 Beta on HP Business Desktops
Page 5
... Windows 7 Beta Upgrade is extremely slow Description: When selecting the Upgrade option during Windows 7 installation, process stalls or is run, PCI Serial Port will not function after resuming from hibernation. Appendix A: Known Anomalies Drive Encryption Anomaly: Systems with disc encryption enabled. This should be ... Run Windows Update. Unrecognized devices in Device Manager Anomaly: Several devices aren't recognized after installing Windows 7 Beta Description:, PCI Serial Port, PCI Simple Communications Controller, and Unknown devices lack drivers in Device Manager.
... Windows 7 Beta Upgrade is extremely slow Description: When selecting the Upgrade option during Windows 7 installation, process stalls or is run, PCI Serial Port will not function after resuming from hibernation. Appendix A: Known Anomalies Drive Encryption Anomaly: Systems with disc encryption enabled. This should be ... Run Windows Update. Unrecognized devices in Device Manager Anomaly: Several devices aren't recognized after installing Windows 7 Beta Description:, PCI Serial Port, PCI Simple Communications Controller, and Unknown devices lack drivers in Device Manager.
Hardware Reference Guide - HP Compaq dc7800 Convertible Minitower
Page 62
drives from drive bay 25 expansion card 20 expansion slot cover 21 front bezel 13 media card reader 25 PCI card 22 PCI Express card 22 Smart Cover Lock 9 S security cable lock 48 HP Business PC Security Lock 50 padlock 49 Smart Cover Lock 9 serial connector 4 serial number location 7 shipping preparation 54 Smart Cover Lock 9 specifications computer 43 memory 16 system board drive connections 29 U unlocking access panel USB ports front panel 2 rear panel 4 9, 48 V ventilation guidelines 53 W Windows Logo key 6 56 Index ENWW
drives from drive bay 25 expansion card 20 expansion slot cover 21 front bezel 13 media card reader 25 PCI card 22 PCI Express card 22 Smart Cover Lock 9 S security cable lock 48 HP Business PC Security Lock 50 padlock 49 Smart Cover Lock 9 serial connector 4 serial number location 7 shipping preparation 54 Smart Cover Lock 9 specifications computer 43 memory 16 system board drive connections 29 U unlocking access panel USB ports front panel 2 rear panel 4 9, 48 V ventilation guidelines 53 W Windows Logo key 6 56 Index ENWW
Illustrated Parts & Service Map - HP Compaq dc7800 Convertible Minitower Business PC
Page 3
...dual USB P3 CPU power J10 Quad stack USB P5 Power button/LED J20 PCI slot 1 P52 Second serial port J21 PCI slot 2 P53 Serial port connector J22 PCI slot 3 P6 Internal speaker J31 PCIe X1, slot 1 P60 SATA0 J32 PCIe...IDE) Controller dc7800 Illustrated Parts & Service Map, CMT Chassis 459785-001 page 3 DriveLock Security - enable/disable System Hardware Interrupts IRQ System Function 0 Timer Interrupt 1 Keyboard 2 Interrupt Controller Cascade 3 Serial Port (COM B) 4 Serial Port (COM A) 5 Unused, available for PCI 6 Diskette Drive 7 Parallel Port (LPT 1)...
...dual USB P3 CPU power J10 Quad stack USB P5 Power button/LED J20 PCI slot 1 P52 Second serial port J21 PCI slot 2 P53 Serial port connector J22 PCI slot 3 P6 Internal speaker J31 PCIe X1, slot 1 P60 SATA0 J32 PCIe...IDE) Controller dc7800 Illustrated Parts & Service Map, CMT Chassis 459785-001 page 3 DriveLock Security - enable/disable System Hardware Interrupts IRQ System Function 0 Timer Interrupt 1 Keyboard 2 Interrupt Controller Cascade 3 Serial Port (COM B) 4 Serial Port (COM A) 5 Unused, available for PCI 6 Diskette Drive 7 Parallel Port (LPT 1)...
Service Reference Guide - HP Compaq dc7800 Business PC
Page 25
...computer to Windows NT. only needed for hard disks on some models, allows you to enable or disable: ● PCI SERR# Generation. ● PCI VGA palette snooping, which VGA controller will prevent it from waking from being used by the operating system and reduces the...keys to select the Advanced > Device Options menu and set resources for or disable onboard system devices (diskette controller, serial port, or parallel port). ● Lists currently installed PCI devices and their IRQ settings. ● Allows you to reconfigure IRQ settings for these devices or to select the Security...
...computer to Windows NT. only needed for hard disks on some models, allows you to enable or disable: ● PCI SERR# Generation. ● PCI VGA palette snooping, which VGA controller will prevent it from waking from being used by the operating system and reduces the...keys to select the Advanced > Device Options menu and set resources for or disable onboard system devices (diskette controller, serial port, or parallel port). ● Lists currently installed PCI devices and their IRQ settings. ● Allows you to reconfigure IRQ settings for these devices or to select the Security...
Service Reference Guide - HP Compaq dc7800 Business PC
Page 52
...Enables/disables the computer's ability to boot from an operating system installed on a network server. (The network controller must reside on the PCI bus or be used to uniquely identify the system.) Keyboard locale setting (for example, English or German) for ATA hard drives. Table...). If neither is successfully entered, the hard drive will only appear when at http://www.hp.com Device Security Enables/disables serial ports, parallel port, front USB ports, system audio, network controllers (some models), and SCSI controllers (some models) Allows you to assign or modify a master ...
...Enables/disables the computer's ability to boot from an operating system installed on a network server. (The network controller must reside on the PCI bus or be used to uniquely identify the system.) Keyboard locale setting (for example, English or German) for ATA hard drives. Table...). If neither is successfully entered, the hard drive will only appear when at http://www.hp.com Device Security Enables/disables serial ports, parallel port, front USB ports, system audio, network controllers (some models), and SCSI controllers (some models) Allows you to assign or modify a master ...
Service Reference Guide - HP Compaq dc7800 Business PC
Page 221
...Clear CMOS. 610-External Storage Device Failure External tape drive not connected. degrading is an incompatibility/problem with another device. Remove any serial port expansion cards. 2. POST Numeric Codes and Text Messages 209 Run Computer Setup. 2. If the error reoccurs, the device may ... card resources and/or run Computer Setup or Windows utilities. 1155-Serial Port Address Conflict Detected Both external and internal serial ports are assigned to COM1. 1. Enter Computer Setup and reset the IRQ in PCI Express slot failed to initialize There is an issue. 912-Computer ...
...Clear CMOS. 610-External Storage Device Failure External tape drive not connected. degrading is an incompatibility/problem with another device. Remove any serial port expansion cards. 2. POST Numeric Codes and Text Messages 209 Run Computer Setup. 2. If the error reoccurs, the device may ... card resources and/or run Computer Setup or Windows utilities. 1155-Serial Port Address Conflict Detected Both external and internal serial ports are assigned to COM1. 1. Enter Computer Setup and reset the IRQ in PCI Express slot failed to initialize There is an issue. 912-Computer ...
Service Reference Guide - HP Compaq dc7800 Business PC
Page 265
...port Second parallel port Double-stacked parallel port, Top = Port B, Bottom = Port A Parallel port over single Serial Port Parallel port over Serial Port and Video Port Parallel port over dual VGA ports DVI connector Keyboard connector, PS/2 (Closest to power supply) Mouse connector, PS/2 Stacked mouse (Top)/keyboard (Bottom) connector Video connector, VGA Primary single USB connector Secondary single USB port... connector Stacked parallel/SCSI connector AGP slot x16 PCI Express slot for security card PCI slots on riser card PCI express slots on riser card Clear password header/jumper USB front...
...port Second parallel port Double-stacked parallel port, Top = Port B, Bottom = Port A Parallel port over single Serial Port Parallel port over Serial Port and Video Port Parallel port over dual VGA ports DVI connector Keyboard connector, PS/2 (Closest to power supply) Mouse connector, PS/2 Stacked mouse (Top)/keyboard (Bottom) connector Video connector, VGA Primary single USB connector Secondary single USB port... connector Stacked parallel/SCSI connector AGP slot x16 PCI Express slot for security card PCI slots on riser card PCI express slots on riser card Clear password header/jumper USB front...
Service Reference Guide - HP Compaq dc7800 Business PC
Page 266
L3 USB rear port choke (2nd) L4 USB rear port choke (3rd) L5 USB front port choke (2nd) P1 P/S connector (20 or 24 pin) P2 Second P/S connector (as required) P3 Processor 12V header P4 Secondary Processor 12V header P5 ... audio P24 Header for front panel USB P25 Internal USB connector 1 P26 Internal USB connector 2 P27 MultiBay header P29 SCSI LED connector P30 PCI extender slot (female) P40 Blade PC graphics connector (outboard) P41 Blade PC graphics connector (inboard) P52 Second serial port 254 Appendix E System Board and Riser Board Reference Designators
L3 USB rear port choke (2nd) L4 USB rear port choke (3rd) L5 USB front port choke (2nd) P1 P/S connector (20 or 24 pin) P2 Second P/S connector (as required) P3 Processor 12V header P4 Secondary Processor 12V header P5 ... audio P24 Header for front panel USB P25 Internal USB connector 1 P26 Internal USB connector 2 P27 MultiBay header P29 SCSI LED connector P30 PCI extender slot (female) P40 Blade PC graphics connector (outboard) P41 Blade PC graphics connector (inboard) P52 Second serial port 254 Appendix E System Board and Riser Board Reference Designators
Service Reference Guide - HP Compaq dc7800 Business PC
Page 274
...processor 186 USDT ReadyBoost card 180 USDT rear chassis fan 188 USDT speaker 182 USDT system board 187 removing expansion slot cover 73 PCI card 74, 122 PCI Express card 74, 122 retired solutions 31 riser board reference designators 252 ROM flash 31 Remote Flash 32 S safety and comfort... identification technology 47 HP Business PC Security Lock 111, 161 HP ProtectTools Security Manager 26 password 41 settings 38 SFF 110 SFF cable lock 110 SFF padlock 110 Smart Cover Lock 45 Smart Cover Sensor 45 USDT 160 serial interface pin assignments 193 serial port CMT removal and replacement 97 ...
...processor 186 USDT ReadyBoost card 180 USDT rear chassis fan 188 USDT speaker 182 USDT system board 187 removing expansion slot cover 73 PCI card 74, 122 PCI Express card 74, 122 retired solutions 31 riser board reference designators 252 ROM flash 31 Remote Flash 32 S safety and comfort... identification technology 47 HP Business PC Security Lock 111, 161 HP ProtectTools Security Manager 26 password 41 settings 38 SFF 110 SFF cable lock 110 SFF padlock 110 Smart Cover Lock 45 Smart Cover Sensor 45 USDT 160 serial interface pin assignments 193 serial port CMT removal and replacement 97 ...
Technical Reference Guide: HP Compaq dc7800 Series Business Desktop Computers
Page 19
...in. [6] Full-height PCI slots require installation of sockets Maximum memory 2 SODIMM 4GB 4 DIMM 8GB 4 DIMM 8GB Serial ports 0 1 std., 1 opt. [1] 1 std., 1 opt. [1] Parallel ports 0 1 1 DVI-D graphics port 1 0 0 Drive bays: Externally accessible Internal 1 2 4 1 1 2 PCIe slots: x16 graphics x1 0 1 [2] 1 [3] [4] 2 [3] 1 [5] 2 PCI 2.3 32-bit 5-V ... [1] 2nd serial port requires optional cable/bracket assembly. [2] PCIe Mini Card slot. [3] Supports low-profile card in ). System Overview Table 2-1 shows the differences in features between the different PC series based ...
...in. [6] Full-height PCI slots require installation of sockets Maximum memory 2 SODIMM 4GB 4 DIMM 8GB 4 DIMM 8GB Serial ports 0 1 std., 1 opt. [1] 1 std., 1 opt. [1] Parallel ports 0 1 1 DVI-D graphics port 1 0 0 Drive bays: Externally accessible Internal 1 2 4 1 1 2 PCIe slots: x16 graphics x1 0 1 [2] 1 [3] [4] 2 [3] 1 [5] 2 PCI 2.3 32-bit 5-V ... [1] 2nd serial port requires optional cable/bracket assembly. [2] PCIe Mini Card slot. [3] Supports low-profile card in ). System Overview Table 2-1 shows the differences in features between the different PC series based ...
Technical Reference Guide: HP Compaq dc7800 Series Business Desktop Computers
Page 20
... (SATA) hard drive in , and headphones out ■ Intel 82566DM 10/100/1000 network interface controller The Q35 chipset provides a major portion of PCI 2.3 slots 0 1 [3] 3 Serial / parallel ports 0 1 [4] 1 [4] Parallel ports 0 1 1 SATA interfaces 1 3 4 Notes: [1] Low-profile slot. System Overview 2.3 System Architecture The systems covered in this guide include the following key components: ■ Intel Pentium...
... (SATA) hard drive in , and headphones out ■ Intel 82566DM 10/100/1000 network interface controller The Q35 chipset provides a major portion of PCI 2.3 slots 0 1 [3] 3 Serial / parallel ports 0 1 [4] 1 [4] Parallel ports 0 1 1 SATA interfaces 1 3 4 Notes: [1] Low-profile slot. System Overview 2.3 System Architecture The systems covered in this guide include the following key components: ■ Intel Pentium...
Technical Reference Guide: HP Compaq dc7800 Series Business Desktop Computers
Page 53
... ICH9 Functions The ICH9 provides various functions through the use GPIO ports and associate registers of programmable general purpose input/output (GPIO) ports. drive) Serial Port (COM1) Interrupt Controller Parallel Port (LPT2) Parallel Port (LPT1) Parallel Port (LPT3) PCI Configuration Address (dword access only ) Reset Control Register PCI Configuration Data (byte, word, or dword access) NOTE: Assume unmarked gaps...
... ICH9 Functions The ICH9 provides various functions through the use GPIO ports and associate registers of programmable general purpose input/output (GPIO) ports. drive) Serial Port (COM1) Interrupt Controller Parallel Port (LPT2) Parallel Port (LPT1) Parallel Port (LPT3) PCI Configuration Address (dword access only ) Reset Control Register PCI Configuration Data (byte, word, or dword access) NOTE: Assume unmarked gaps...
Technical Reference Guide: HP Compaq dc7800 Series Business Desktop Computers
Page 88
... on the PCI bus can be enabled to cause the power control logic to generate the PS On. Note that certain circuits receive auxiliary power while the system is turned off. Using an AC power strip to Chapter 5, "Network Support" for more information. signal on a serial port can be ... power "wake-up" of the system due to the occurrence of a magic packet, serial port ring, or PCI power management event (PME). Power Management Event A power management event that asserts the PME- signal on the PCI bus. Power and Signal Distribution 7.3.2 Wake Up Events The PS On signal can be configured...
... on the PCI bus can be enabled to cause the power control logic to generate the PS On. Note that certain circuits receive auxiliary power while the system is turned off. Using an AC power strip to Chapter 5, "Network Support" for more information. signal on a serial port can be ... power "wake-up" of the system due to the occurrence of a magic packet, serial port ring, or PCI power management event (PME). Power Management Event A power management event that asserts the PME- signal on the PCI bus. Power and Signal Distribution 7.3.2 Wake Up Events The PS On signal can be configured...
Technical Reference Guide: HP Compaq dc7800 Series Business Desktop Computers
Page 90
... drive connector PATA (IDE), primary, connector PATA (IDE), secondary, connector Front panel audio header Front panel USB header Serial port, secondary, header Serial port, primary connector Serial port, primary header SATA0 (controller 1, primary) connector (dark blue) SATA1 (controller 1, secondary) connector (white) SATA4 (controller...Stacked RJ-45 & dual USB connectors Stacked quad USB connectors PCI 2.3 connector PCI 2.3 connector PCI 2.3 connector PCIe x1 connector PCIe x1 connector PCIe x16 (graphics) connector Parallel port, DB-25 connector Stacked keyboard, mouse PS/2 connectors VGA...
... drive connector PATA (IDE), primary, connector PATA (IDE), secondary, connector Front panel audio header Front panel USB header Serial port, secondary, header Serial port, primary connector Serial port, primary header SATA0 (controller 1, primary) connector (dark blue) SATA1 (controller 1, secondary) connector (white) SATA4 (controller...Stacked RJ-45 & dual USB connectors Stacked quad USB connectors PCI 2.3 connector PCI 2.3 connector PCI 2.3 connector PCIe x1 connector PCIe x1 connector PCIe x16 (graphics) connector Parallel port, DB-25 connector Stacked keyboard, mouse PS/2 connectors VGA...
Computer Setup (F10) Utility Guide
Page 12
...the computer if the sensor detects that the cover has been removed. Setup Password requires that the setup password be either a PCI expansion card or embedded on NIC models only; the network controller must be entered to set ) (allows viewing, but not ... If neither 6 Computer Setup (F10) Utility ENWW Device Security Allows you to set Device Available/Device Hidden for ● Serial ports ● Parallel port ● All USB ports ● Front USB ports ● System audio ● Network controllers (some models) ● Legacy diskette ● Embedded security device (some models...
...the computer if the sensor detects that the cover has been removed. Setup Password requires that the setup password be either a PCI expansion card or embedded on NIC models only; the network controller must be entered to set ) (allows viewing, but not ... If neither 6 Computer Setup (F10) Utility ENWW Device Security Allows you to set Device Available/Device Hidden for ● Serial ports ● Parallel port ● All USB ports ● Front USB ports ● System audio ● Network controllers (some models) ● Legacy diskette ● Embedded security device (some models...
Computer Setup (F10) Utility Guide
Page 16
... the lowest power consumption available on some models, allows you to reconfigure IRQ settings for or disable onboard system devices (diskette controller, serial port, or parallel port). ● Lists currently installed PCI devices and their IRQ settings. ● Allows you to disable them entirely. This option may be the "boot" or primary VGA controller...
... the lowest power consumption available on some models, allows you to reconfigure IRQ settings for or disable onboard system devices (diskette controller, serial port, or parallel port). ● Lists currently installed PCI devices and their IRQ settings. ● Allows you to disable them entirely. This option may be the "boot" or primary VGA controller...
Troubleshooting Guide
Page 58
...or run Computer Setup or Windows utilities. 1155-Serial Port Address Conflict Detected Both external and internal serial ports are assigned to reconfigure without the drive. 611-Primary Floppy Port Address Assignment Conflict Configuration error. Reconfigure card ...PCI Express Link reoccurs, the device may not work with this Try rebooting the system. Clear CMOS. (See Appendix B, Password Security and Resetting CMOS on page 58.) 3. Remove any serial port expansion cards. 2. system 1151-Serial Port A Address Conflict Detected Both external and internal serial ports...
...or run Computer Setup or Windows utilities. 1155-Serial Port Address Conflict Detected Both external and internal serial ports are assigned to reconfigure without the drive. 611-Primary Floppy Port Address Assignment Conflict Configuration error. Reconfigure card ...PCI Express Link reoccurs, the device may not work with this Try rebooting the system. Clear CMOS. (See Appendix B, Password Security and Resetting CMOS on page 58.) 3. Remove any serial port expansion cards. 2. system 1151-Serial Port A Address Conflict Detected Both external and internal serial ports...